T&C TC36.NG05.C Installation Instructions Manual

Manual is about: HEARTWOOD BURNER FOR TC36 & TC36 AR

Summary of TC36.NG05.C

  • Page 1

    290409-12 tc36.Ng05.C 5056.427.C45 installer: leave this manual with the appliance. Consumer: retain this manual for future reference. These instructions are supplementary to the installation and operating instructions supplied with the fireplace and should be kept together. Refer to the installatio...

  • Page 2: Contents of Package

    Contents of package 2 tc36.Ng05.C 290409-12 • burnerassembly(includingpilotandmanifold) • loggrate • tc36heartwoodlogs • embermaterial • hardwarepackage • airdeflector • coalchunks • vermiculite.

  • Page 3: Burner Installation

    If this fireplace is to be used on propane please convert prior to installtion. See pages 6 – 8. 3 tc36.Ng05.C 290409-12 1. Attachtheburnerassemblytothefloor shield in the bottom of the firebox with twoscrews.Ensurethatthefrontedge oftheburnerisflushwiththefrontofthe shield. (fig.#1) 2. Attachsparke...

  • Page 4: Ember Material

    Note: ember material placement and amount will affect flame appearance. More ember material results in lower flame height. Add or remove as needed until desired flame affect. Reduce the amount used on propane models, as too much will create soot 4 tc36.Ng05.C 290409-12 fig. #5 ember material fig. #6...

  • Page 5: Log Placement

    5 tc36.Ng05.C 290409-12 fig. #9 fig. #11 fig. #12 fig. #10 fig. # 7 gas plumbing and vent connections should be completed before proceeding. Thelogsarefragile,andshouldbehandledwithcare.Unpackandinspectlogset.There should be a total of seven logs. Positionthelogsasindicatedbythefollowingpictures.The...

  • Page 6: Propane Conversion

    Propane conversion if the unit is to be used on propane, convert as follows using the compo- nents supplied with this fireplace: caution the gas supply and electrical power must be shut off before proceeding with the conversion. Fig. # 17 fig. # 18 fig. # 16 warning this conversion kit shall be inst...

  • Page 7

    Minimum rate screw 7. Witha7/16”wrenchloosenthepilothead on the pilot assembly by a half-turn (fig.#19) 8. Slidethepilotadjustmentbandoverand ensure that the hole in the orifice band is showing.(fig.#20showsngposition, fig.#21showslpposition) 9. Remove the minimum rate screw located in the valve. (f...

  • Page 8

    8 tc36.Ng05.C 290409-12 minimum rate screw ng lp fig #23 fig #24 fig #25 fig #26 10. Replace the minimum rate screw with the one provided in the propane conversion kitsuppliedwiththisfireplace.Ensure that the screw is fully installed. (fig.#23) 11. Pullofftherubbercapfromthetopof thepressureregulato...

  • Page 9: Gas Pressure Check

    9 tc36.Ng05.C 290409-12 1. Remove the plug from the manifold test port. The plug is located between the rightsidelintelandfireboxside(bottom port).(fig.#27) 2. Thread the extension test fitting into the opentestport.(fig.#28) 3. Attachapressuregaugeontothe fitting. 4. When testing is complete remove...

  • Page 10: Flame Adjustment

    10 tc36.Ng05.C 290409-12 fig. # 29 the air shutter on the burner tube controls the primary combustion air to the gas burner andispresetatthefactoryfornaturalgasfuel.Someadjustmentmaybenecessaryto obtaindesiredflameandtoeliminatecarbondeposits.Evaluateflameappearanceafter thefireplacehasreachedoperat...

  • Page 11: Replacement Parts

    11 tc36.Ng05.C 290409-12 replacement parts item .......Description ............................................Part no. #1..........Tc36.Ng05 burner assembly .... Tc36.Ng05.C #2..........9 pcs log set ................................. 5098.74611 #3..........Orifice, natural gas (#30) ......... 5022....

  • Page 12

    Technical support: 1-888-715-2664 www.Townandcountryfireplaces.Net 2975 allenby rd., duncan, bc v9l 6v8 printedincanada.