T&C TC42 Instructions For Use Manual

Manual is about: CHALET II BURNER KIT For use with: Model TC42 Series C

Summary of TC42

  • Page 1

    281009-12 tc42.Ng01.C 5056.426.C1 installer: leave this manual with the appliance. Consumer: retain this manual for future reference. Tc42 chalet burner kit instructions part# tc42.Ng01.C for tc 42 series c these instructions are supplementary to the installation and operating instructions supplied ...

  • Page 2: Contents of Package

    Contents of package 2 tc42.Ng01.C 281009-12 • burner assembly • log grate • tc42 logs • ember material • hardware package.

  • Page 3: Burner/ Grate Installation

    3 tc42.Ng01.C 281009-12 1. Attach the burner assembly to the fl oor of the fi rebox with two screws. (fig. # 1) 2. Attach the manifold supply tube to the bulk head fi tting and tighten. (fig. # 2) ensure that there are no leaks. 3. Attach the pilot supply tube to the bulk head fi tting and tighten. ...

  • Page 4: Ember Material Placement

    4 tc42.Ng01.C 281009-12 a large bag of ember material is shipped with the fi replace and needs to be installed to ensure optimum performance and fl ame appearance. Pull apart the material into ember size pieces (approximately 1” squares) and gently place them into the burner pan. Do not compress, le...

  • Page 5: Log Placement

    5 tc42.Ng01.C 281009-12 fig. #9 fig. #12 fig. #11 2 3 1 5 6 4 note: improper placement of logs will cause sooting on internal parts and glass. The logs may need to be repositioned slightly to avoid excessive fl ame impingement. Fig. # 7 gas plumbing and vent connections should be completed before pr...

  • Page 6: Propane Conversion

    Propane conversion if the unit is to be used on propane convert as follows using the components supplied with this fi replace: caution the gas supply and electrical power shall be shut off before proceeding with the conversion. Fig. # 14 fig. # 15 fig. # 13 warning this conversion kit shall be insta...

  • Page 7

    Minimum rate screw 7. With a 7/16” wrench loosen the pilot head on the pilot assembly by a half-turn (fig. #16) 8 slide the pilot adjustment band over and ensure that the hole in the orifi ce band is showing. (fig. #17 shows ng position, fig. # 18 shows lp position) 10. Remove access panel to access...

  • Page 8

    Warning the access panel including gasket must be reinstalled after conversion/ installation or servicing has been completed. Failure to do so will overheat and cause premature failure of the control system. 8 tc42.Ng01.C 281009-12 ng lp fig #21 fig #22 fig #24 12. Pull off the rubber cap from the t...

  • Page 9: Gas Pressure Check

    9 tc42.Ng01.C 281009-12 1. Remove the pressure test port plug from the manifold test port. The plug is located between the right side lintel and fi rebox side (bottom port). (fig. #25) 2. Thread the extension test fi tting into the open test port. (fig. #26) 3. Attach a pressure gauge onto the fi tt...

  • Page 10: Burner Flame Adjustment

    10 tc42.Ng01.C 281009-12 fig. # 27 fig. # 28 the air shutter on the burner tube controls the primary combustion air to the gas burner and is pre-set closed at the factory for natural gas fuel. Propane requires fully open shutter setting. Some adjustment may be necessary to obtain desired fl ame and ...

  • Page 11

    * 4 5 6 11 tc42.Ng01.C 281009-12 replacement parts tc42.Ng01.C 1a 1g 1f 1e 1d 1c 1b 2f 2e 2d 2c 2b 2a item .......Description ............................................Part no. #1.......... Burner assembly......................... Tc42.Ng01.C #2.......... 6 pcs log set ...............................

  • Page 12

    Technical support: 1-888-715-2664 www.Townandcountryfi replaces.Net 2975 allenby rd., duncan, bc v9l 6v8 printed in canada.