020511-16 tc42.Ng06c 5056.426c1a installer: leave this manual with the appliance. Consumer: retain this manual for future reference. These instructions are supplementary to the installation and operating instructions supplied with the fi replace and should be kept together. Refer to the installation...
2 tc42.Ng06c 020511-16 contents of package • burner assembly • log grate • tc36 logs • ember material • hardware package burner installation 1. Place the keyhole slots in the burner over the two screws located in the fi rebox base. (fig. #1 & 1a) 2. Slide the burner back to engage the screws in the ...
3 tc42.Ng06c 020511-16 bulkhead plate 2 screws 4. Secure the electrical bulkhead plate and gasket to the fi rebox. (2 screws) attach the ignition and sensor wires to the module. Red end to the connector marked by the red dot, white end to the connector marked by the white dot fig.#2 & fig.#3 fig. # ...
4 tc42.Ng06c 020511-16 pilot supply tube main gas supply tube fig. # 5 5. Attach the pilot and gas supply tubes to the bulk head fi tting and tighten. (fig. # 4) ensure the connections are gas tight. Conceal the spark and sensor wires below the supply tubes. A panel set must now be installed. See in...
5 tc42.Ng06c 020511-16 ember material placement log grate glowing embers ember material a large bag of ember material is shipped with the fi replace and needs to be installed on the burner to ensure optimum performance and fl ame appearance. 1. Pull apart the material into ember size pieces (approxi...
6 tc42.Ng06c 020511-16 fig. #9 fig. # 8 log #2 log #3.
7 tc42.Ng06c 020511-16 fig. #11 fig. #10 log #4 log #5.
8 tc42.Ng06c 020511-16 fig. #13 log #7 note: improper placement of logs will cause sooting on internal parts and glass. Fig. #12 log #6.
9 tc42.Ng06c 020511-16 propane conversion if the unit is to be used on propane, conver t as follows using the components supplied with this burner: caution the gas supply and electrical power must be shut off before proceeding with the conversion. Fig. # 15 fig. # 16 fig. # 14 warning this conversio...
10 tc42.Ng06c 020511-16 minimum rate screw 7. With a 7/16” wrench loosen the pilot head on the pilot assembly by a half-turn (fig. #17) 8. Slide the pilot adjustment band over and ensure that the hole in the orifi ce band is showing. (fig. #19 shows ng position, fig. # 20 shows lp position) 9. Remov...
11 tc42.Ng06c 020511-16 lp gas/ du gaz lp 12.5 in/wc /12.5 po/c.E. (3.11 kpa) 13.9 in/wc / 13.9 po/c.E. (3.45 kpa) 11.0 in/wc / 11.0 po/c.E. (.95 kpa) 3/32” (2.38 mm) max.: 61,000 (17.9) min.: 46,200 (13.5) 260411 6-tc42c 5052.5206c date: ______________________ by / par: ___________________ kit # tc...
12 tc42.Ng06c 020511-16 1. Remove the plug from the manifold test port. The plug is located between the right side lintel and fi rebox side (bottom port). (fig. # 26) 2. Thread the extension test fi tting into the open test port. (fig. #27) 3. Attach a pressure gauge onto the fi tting. 4. When testi...
13 tc42.Ng06c 020511-16 fig. # 28 the air shutter on the burner tube controls the primary combustion air to the gas burner and is preset at the factory for natural gas fuel. Some adjustment may be necessary to obtain desired fl ame and to eliminate carbon deposits. Evaluate fl ame appearance after t...
14 tc42.Ng06c 020511-16 replacement parts item .......Description ............................................Part no. #1.......... Burner assembly......................... Tc42.Ng06c #2.......... 7 pcs log set(tc42) ...................... 5094.42161 #3.......... Orifice, natural gas (#25) ............
15 tc42.Ng06c 020511-16.
Technical support: 1-250-748-1184 www.Townandcountryfi replaces.Net 2975 allenby rd., duncan, bc v9l 6v8 printed in canada.