T&C TC54 Instructions Manual

Manual is about: COUNTRY HOME BURNER KIT TC54.NG02.C

Summary of TC54

  • Page 1

    060906-16 tc54.Ng02 c 5056.4256 these instructions are supplementary to the installation and operating instructions supplied with the fi replace and should be kept together. Refer to the installation and operating instructions for proper gas supply, safety requirements and operating instructions. Tc...

  • Page 2: Package

    060906-16 tc54.Ng02.C • burner assembly (including pilot and manifold) • log grate (including upper burner and pilot assembly) • ember material (two bags) • hardware package 1. Attach the lower burner assembly to the fl oor of the fi rebox with two screws. (fig. # 1) 2. Attach the manifold supply tu...

  • Page 3

    060906-16 tc54.Ng02.C 3. Attach the pilot supply tube from the lower burner pilot to the front bulk head fi tting and tighten. (fig. # 3) ensure there are no leaks. 4. Attach spark electrode (orange) and sensor leads from lower burner pilot to the front electrical bulk head. ( fig. # 4) (the spark e...

  • Page 4

    060906-16 tc54.Ng02.C 8. Attach the pilot supply tube from the upper burner pilot to the rear bulk head fi tting and tighten. (fig. # 9) ensure there are no leaks. 9. Attach spark electrode (orange) and sensor leads from upper burner pilot to the rear electrical bulk head. (fig. # 10) (the spark ele...

  • Page 5: Propane Conversion

    060906-16 tc54.Ng02.C if the unit is to be used on propane convert as follows using the components supplied with this fi replace: warning this conversion kit shall be installed by a qualifi ed service agency in accordance with the manufacturer's instructions and all applicable codes and requirements...

  • Page 6

    060906-16 tc54.Ng02.C 4. Apply a small amount of pipe joint compound to the threads of the propane burner orifi ce (marked #43) to ensure a good seal, before screwing it into the fi tting. (fig. #13) 5. Open shutter fully. (fig. #14) 6. Reinstall the manifold to the lower burner using the screws pre...

  • Page 7

    060906-16 tc54.Ng02.C 12. With a 7/16” wrench loosen the pilot head on the pilot assembly attached to the lower burner assembly (fig. #17) 13. Slide the pilot adjustment band over and ensure that the hole in the orifi ce band is showing. (fig. #18 indicates ng position, fig. #19 indicates lp positio...

  • Page 8

    060906-16 tc54.Ng02.C 16. Remove the minimum rate screw located in each valve. (fig. #21) 17. Replace the minimum rate screw with the one provided in the propane conversion kit supplied with this fi replace. Ensure that the screws are fully seated. (fig. #22) 18. Pull off the rubber cap from the top...

  • Page 9: Gas Pressure Check

    060906-16 tc54.Ng02.C 1. Remove the blanking plug from the pressure test port. The plug is located between the right side lintel and fi rebox side. (fig. # 26 & 26a) 2. Thread the extension test fi tting into the open test port. (fig. # 27) 3. Attach a pressure gauge onto the fi tting. 4. When testi...

  • Page 10: Ember Material

    060906-16 tc54.Ng02.C two bags of ember material is shipped with the fi replace and need to be installed to ensure optimum performance and fl ame appearance. Pull apart the material into ember size pieces (approximately 1” squares) and gently place them into the lower burner pan. Do not compress, le...

  • Page 11: Log Set Assembly

    060906-16 tc54.Ng02.C the logs are packaged in a foam pack inside the box, and are fragile, and should be handled with care. Unpack and inspect log set. There should be a total of seven logs. Gas plumbing and vent connections should be completed before proceeding. Position the logs exactly as indica...

  • Page 12

    060906-16 tc54.Ng02.C 22 3 1 6 4 5 7 fig. #33 fig. #34 fig. #35 12.

  • Page 13: Burner Flame Adjustment

    060906-16 tc54.Ng02.C an air shutter on each of the burner tubes controls the primary combustion air to the gas burner and is preset closed at the factory for natural gas fuel. Some adjustment may be necessary to obtain desired fl ame and to eliminate carbon deposits. Evaluate fl ame appearance afte...

  • Page 14: Replacement Parts

    060906-16 tc54.Ng02.C item description part no. 1 log grate assembly ......................................................................................... Tc54.8181 2 lower burner assembly ...............................................................................Tc54.90859 3 pilot bracket ....

  • Page 15: Notes

    060906-16 tc54.Ng02.C 15 notes.

  • Page 16

    Technical support: 1-877-715-2664 www.Townandcountryfi replaces.Net 2975 allenby rd.., duncan, bc v9l 6v8 printed in canada.