Hardware Selectable Functions
These are set using the DIP switches and are only read with the printer when the printer is turned on.
SW 1:
Print format
Default settings
SW 2:
Handshake protocol
Print format
24cpl
SW 3:
Baud rate
Handshake protocol
Hardware
SW 4:
Baud rate
Baud rate
9600
SW 5:
Character height
Character height
Normal
SW 6:
Character width
Character width
Normal
SW 7:
Line spacing
Extra blank lines
Inserted
SW 8:
Auto wake up
Auto wake up
Disabled
See below for a detailed explanation of the DIP switch settings (Fig 2: illustrates the default DIP switch settings).
To change the DIP switch settings, (make sure the printer is off before making any changes), use a pencil or similar
thin pointed object.
Auto Wake Up
The MCP9810-112 incorporates an auto wake up facility which minimises the printer’s power consumption. If auto
wake up is enabled, the printer will turn itself off after approximately five minutes of inactivity on the receive data
line. The printer will then wake up only when activity is detected on the receive line.
To wake the printer up, the user should ignore the status of the CTS line and send a NUL character (00H) to the
printer. The user should then wait at least 0.7 seconds for the printer to initialise before sending further data. Once
the printer has initialised, handshaking should be resumed.
Since the NUL character is non-printable, this procedure may be followed even if the printer is awake and will not
cause unwanted characters to be printed.
To enable the auto wake up facility, place DIP switch 8 in the UP position. If the switch is in the DOWN position the
printer will remain operational until turned off via the power switch.
If auto wake up is enabled, the printer may not turn on when power is applied via the power switch. Sending a NUL
character will cause the printer to power up normally.
Country
Code
Decimal
Hex
USA
ESC R 0 27 82 0
1B 52 00
France
ESC R 1 27 82 1
1B 52 01
Germany
ESC R 2 27 82 2
1B 52 02
UK
ESC R 3 27 82 3
1B 52 03
Denmark I
ESC R 4 27 82 4
1B 52 04
Sweden
ESC R 5 27 82 5
1B 52 05
Italy
ESC R 6 27 82 6
1B 52 06
Spain
ESC R 7 27 82 7
1B 52 07
Japan
ESC R 8 27 82 8
1B 52 08
Norway
ESC R 9 27 82 9
1B 52 09
Denmark II ESC R 10 27 82 10
1B 52 0A
Software Selectable Functions
Bold
Underline
Double height
Double width
Graphics
Horizontal tab, plus setting
Form feed, plus setting
11 selectable international character sets (see right)
Reverse printing
Inverse printing
Reset
Barcodes
SW
SW
SW
SW
SW
SW
SW SW
1
2
3
4
5
6
7
8
24 Character per line
ON
48 Charactere per line
OFF
Software handshake
ON
Hardware handshake
OFF
1200 Bauds
OFF OFF
2400 Bauds
ON
ON
4800 Bauds
OFF
ON
9600 Bauds
ON
OFF
Normal height
ON
Double height
OFF
Normal width
ON
Double width
OFF
Exta blank lines inserted
ON
No extra blank lines
OFF
Auto wake up disabled
ON
Auto wake up enabled
OFF
Paper Selection
The setting of DIP switch 7 selects the type of
paper being used. If the MCP9810-112 is
loaded with label stock, SW7 must be placed in
the Up (OFF) position for correct operation to
take place.
The ‘ESC f ‘ sequence, which advances to the
next label, can only be used if SW7 is Up.
Since dual ply paper is less sensitive than
normal thermal paper, the ‘Esc !’ sequence
should be used to increase the print density to 4
when printing on dual ply (see Print Density for
details).