Taiden TMX-0404SDI Installation And Operation Manual

Manual is about: professional high definition digital video tracking matrix switcher

Summary of TMX-0404SDI

  • Page 1

    High definition digital video tracking matrix switcher professional matrix switchers installation and operation manual v 1.1.

  • Page 2

    I remark: all rights reserved for translation, reprint or reproduction contents may change without prior announcement all technical specifications are guideline data and not guaranteed features taiden co., ltd. Is not responsible for any damage caused by improper use of this manual the equipment mus...

  • Page 3

    Important safety instruction 1. Read and keep these instructions. 2. Heed all warnings and follow all instructions. 3. The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on the apparatus. 4. The mains plug serving as a ...

  • Page 4

    Important safety instruction the exclamation mark within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. Iii attention: installation should be performed by qualified se...

  • Page 5: Contents

    Contents installation & user guide........................................................................................................... V chapter 1. High definition digital video tracking matrix switchers............................................1 1.1 functions and indications .................

  • Page 6

    Installation & user guide about this manual this manual is a comprehensive guide to the installation and operation of taiden sdi series high definition digital video tracking matrix switchers. It includes: connection and operation, protocol and control code, etc. The manual is divided into the follo...

  • Page 7

    Chapter 1. High definition digital video tracking matrix switchers 1.1 functions and indications figure 1.1 panels of sdi matrix switcher front panel: 1. “menu” button a) if in current state, press “menu” go to main menu; b) if in menu state, press “menu” go to sub menu; c) select/deselect in networ...

  • Page 8

    2 1.2 installation and connection 1.2.1 installation 1u high definition digital video tracking matrix switcher just needs to put it into the cabinet, and fix it by screws. As figure 1.3. Figure 1.3 installation 1.2.2 connection between mixed switcher and pc high definition digital video tracking mat...

  • Page 9

    Figure 1.4 connection example for input and output devices to tmx-0808sdi matrix switcher 3.

  • Page 10

    1.3 setup and operation 1.3.1 menu setup 1.3.1.1 menu setup to explain menu setup of sdi series matrix switcher, tmx-0808sdi serves as example. Tmx-0808sdi main interface: press “menu” to enter main menu and press “Õ/Ö” until “setting” prompts; press “menu” again to enter setup menu, including: 1. R...

  • Page 11

    3. Demo switch delay 5. Sync switch delay the interval ranges from 2 seconds to 60 seconds by steps of 2 seconds. 4. Com1 protocol central control system can be selected from taiden, extron or other, please add correct protocol according to user request. This item can’t be adjustable. 6. Test button...

  • Page 12

    8、video track type when video track is on, camera protocol can be selected from hcs-3316rs232/ hcs-3316rs485/ sony hd1/ pelco d/ pelco dc/ pelco p1/ pelco p2/ panasonic cs950/ panasonic he100/ samsung c6407p/ hcs-3313c/ sony d70/ sony d100/ sony brc-z330/ sony brc300/ sony brc700. Please select corr...

  • Page 13

    1.3.2 switch operation to explain menu operation of sdi series matrix switcher, tmx-0808sdi type serves as example. All sdi series matrix switcher can refer to it. Tmx-0808sdi main interface: press “menu” to enter switch menu, including: 1. Switch video 2. Switch through * switch through one channel...

  • Page 14

    2. Switch through switch through one input channel or all input channels to corresponding output channel(s). Example: switch through channel 2. 3. Close close one output channel or all output channels. Example: close output channel 2. 4. Save scene save current video signal to appointed scene. 10 sc...

  • Page 15

    6. Undo undo last switch operation. 7. Demo switch switches one by one all possible combinations from 1 → 1, 1→2, …, 1→8, 2→1, 2→2, …, 2→8, …, 8→1, 8→ 2, …to 8→8. The interval can be setup via setup menu (refer to section 1.3.1). 8. Setting setup menu. 9. Status request corresponding state of input ...

  • Page 16: Chapter 2. Ir Remote Control

    Chapter 2. Ir remote control 1. Basic function users can use remote control to operate matrixes, the function of remote control key is the same as matrix front panel key (please refer to chapter 1 for detailed instructions). Please refer to sections of menu operation for detailed operation method of...

  • Page 17

    Chapter 3. Communication protocol and control code this code system is used for controlling and operating taiden professional matrix switchers by central control system or user programming software. Protocol: baud rate: 9600; data: 8 bits; stop: 1 bit; parity check bit: no type code description lock...

  • Page 18

    Save[x]. Save current status to scene [x] recall[x]. Recall scene x] clear[x]. Clear scene [x], status of all output channel are closed type*. Query the matrix type status[x1]. Query the input status of the output channel [x1] status. Query the input status of all output channels [x1]*[x2]! Video an...

  • Page 19: Chapter 4. Technical Data

    13 chapter 4. Technical data type spec. Tmx-0404sdi tmx-0804sdi tmx-0808sdi video date rates 143 mbps - 2.97 gbps date types 8 bit or 10 bit video input connectors 4 × bnc female 8 × bnc female input cable equalization typical equalization cable length (belden 1694a standard cable): 100 m @ 2.97 gbp...

  • Page 20

    14 type spec. Tmx-0404sdi tmx-0804sdi tmx-0808sdi general spec. Power supply 100 v ac - 240 v ac,50/60 hz temperature operating: 0 °c to + 50 °c; storage: -20 °c to + 70 °c humidity storage and operating: 10% to 90% dimensions h × w ×d (mm) 483×208×43 (1u high, full rack width) weight 2.7 kg mean ti...

  • Page 21

    Www.Taiden.Com taiden industrial co.,ltd. Copyright by taiden last revision: 09/2014.