3. INSTALLATION
- Joining the boundary wire .
If the boundary wire is not long enough
and needs to be spliced: Use original
solderless couper. It is waterproof and
gives a reliable electrical connection.
To splice: Insert both cable ends in the
coupler. Now press down the button on
top of the connector fully. Use a pair of
pliers or the like, as the button on the
connector is difficult to press down by
hand.
Correct corner set up,
using several angle to
avoid an angle of less
than 90°.
Greater than
2.5m
- Care must be taken not to create a corner sharper shorter than 90
degrees when setting up virtual wire. A corner sharper less than 90
degrees can cause the mower to lose track of virtual wire. We can make
greater than 90 degrees corner like follow picture shows.
- P24-
Proper setup in sharp corners
Incorrect corner
setup
- On multi-spindle appliances, take care as rotating one blade can
cause other blades to rotate.
- Connect two terminals of virtual wire to charging station, and ensure
virtual wire is in good connecting. (Light on charging station is in
colorless).
- Insert charger to charging station and screw it. And then connect
charger to power supplier. Ensure charging station is in good
connecting, light on charging station is in Green.
1.In case LINE is on. Take the mower to
start point.
2. Press power button from control panel.
3. Clockwise rotate Emergency switch,
the mower start. Display shows as
picture.
4. Input password (Initial password:0000)
the mower enters taskstate.
5.2 Starting the mower
5. USE
blades and bolts in sets to preserve balance.
IMPORTANT INFORMATION
User can' t start the mower if virtual wire and
charging station has problem.
- P29-
Start point