Takenaka System FS5100SPL Instruction Manual - page 18
N08A29;18/33
- 18 -
S.FORM:
The current shutter operation mode is displayed. The left is either continuous (NORMAL) or asynchronous
(ASYNC), and the right is either high speed (HIGH) or low speed (LOW).
SCAN:
The current scanning system is displayed. It is either all pixel readout scan (NORMAL) or partial readout
scan (PARTIAL). (
→
See “Priority relationship among scan mode setting items” described in another
section)
PWC:
Whether the position “9” of the shutter switch for the
asynchronous shutter operation is used (ENABLED) or not
used (DISABLED) is selected.
BZ:
This is to switch between (ON) and (OFF) for the confirmation
sound to be activated when switch manipulation is made.
BAUD:
The baud rate used for RS-232C communication is displayed.
Vinit2:
The polarity of the trigger signal via CC1 of Camera Link is set.
The factory default is negative logic (NORMAL). When
(INVERTED) is selected, positive logic input is used.
STRB-C:
ON/OFF is set for the strobe signal (STRB) output for the
continuous shutter operation. When (ON) is selected, the
strobe signal is output even in the continuous shutter mode.
(Note) The strobe signal is always output in the asynchronous shutter mode
regardless of this setting.
PATTERN:
This is to switch between (ON) and (OFF) for the test pattern
output.
bit:
This is to switch between (8 bits) and (10 bits) for the bit of the
image output.
FORM.:
SINGLE (1ch output) is displayed as the CCD output system.
VSUB:
The setting value of Vsub voltage (substrate voltage of CCD
element) is displayed.
Since the value is optimally set before shipment, the user is
not required to change it as a general rule.
* The following items are for display only; they cannot be directly changed
on the menu. These are automatically updated when a corresponding
change is made using the switches:
MS=
The current position of the mode switch is displayed.
SS=
The current position of the shutter setting switch (EXP.) is
displayed.
MF=
The information (16 bits x 2 sets) of the internal mode flags
of the camera (internal flags to determine operation) is
displayed in the hexadecimal system. The details of the
internal flags are described later.
Tc=
The current internal temperature of the camera is displayed in Celsius. The temperature data are refreshed
every 0.4 seconds.
FS5100SPL
[V.X.XX]
Menu display of Setting Group 2
MENU2
MENU
: ON
PWC
: DISABLED
-
: (Reserved)
MS=A SS=7
MF=0008.0000
FS5100SPL
[V.X.XX]
Menu display of Setting Group C
MENU 3
MENU
: ON
BZ
: ON
BAUD
: 9600bps
-
: (Reserved)
-
: (Reserved)
Vinit 2
: NORMAL
STRB-C : OFF
MS=C SS=7
MF=0008.0000
FS5100SPL
[V.X.XX]
Menu display of Setting Group D
MENU 4
MENU
: ON
PATTERN : OFF
bit
: 8bit
FORM.
: SINGLE
-
: (Reserved)
-
: (Reserved)
VSUB
: 204=H'CC
MS=C SS=7
MF=0008.0000
MS=1 SS=7
MS=1 SS=7
ID: CAMERA-1
FS5100SPL
ID not specified
ID specified