Talkswitch owner friendly Specifications Manual

Other manuals for owner friendly: User Manual

Summary of owner friendly

  • Page 1

    The owner friendly ® phone system for small business vs hardware specification guide.

  • Page 2

    Copyright © 2012 fortinet, inc. All rights reserved. Fortinet®, fortigate®, fortiguard®, forticare®, fortimanager®, fortianalyzer®, and talkswitch® are registered trademarks of fortinet, inc. And other fortinet names herein may also be registered trademarks and/or common law trademarks of fortinet. ...

  • Page 3

    T a b l e o f c o n t e n t s i i i ta b l e o f co n te n t s introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 what you should know . . . . . . . . . . . . . . . . ....

  • Page 4

    I v t a b l e o f c o n t e n t s safety and regulatory information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 safety precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 5

    V s h a r d w a r e s p e c i f i c a t i o n g u i d e 1 i n t ro d u c t i o n the phone system you have purchased is designed and supplied to meet the technical standards for use in specific countries and for connection to the major telephone service providers in those countries. It is subject to...

  • Page 6

    2 v s h a r d w a r e s p e c i f i c a t i o n g u i d e power and lightning surge protection surge protection devices are recommended to protect the system in areas subject to lightning or power surges. Please consult your reseller for recommended surge protection devices. If the system has been s...

  • Page 7

    V s h a r d w a r e s p e c i f i c a t i o n g u i d e 3 sp e ci f i c a t i o n s interfaces interface specifications talkswitch models 240vs 244vs 248vs 280vs 284vs 288vs telephone lines (fxo) 2 2 2 2 2 2 analog extensions (fxs) 4 4 4 8 8 8 voip ports 0 4 8 0 4 8 voip numbers 0 12 24 0 12 24 loca...

  • Page 8

    4 v s h a r d w a r e s p e c i f i c a t i o n g u i d e analog extension specifications telephone line specifications dimensions weight connector type rj-11, 2-pin trunk type loop start interface impedance either 600 Ω, 900 Ω, tbr21, bt complex, au complex or za complex, depending on region. Loop ...

  • Page 9

    V s h a r d w a r e s p e c i f i c a t i o n g u i d e 5 regulatory approvals acta tia/eia/is-968a and fcc part 68, industry canada cs-03 fcc part 15b, industry canada ices-003 power adapter complies with ul and csa reduction of hazardous substances (rohs) directive 2002/95/ec voip features (models...

  • Page 10

    6 v s h a r d w a r e s p e c i f i c a t i o n g u i d e i n s t a l l a t i o n upgrading systems as your business grows, you can add capacity for telephone lines, voip lines and extensions to the systems. You can add capacity in several ways: add units to your network: up to 4 units can be combin...

  • Page 11

    V s h a r d w a r e s p e c i f i c a t i o n g u i d e 7 what the flashing lights mean a unit flashes the lights on the front panel in patterns to show system activity and diagnostic conditions, as described in chapter 6 of the talkswitch user guide. Unit back panel the pf box between e4 and l1 rep...

  • Page 12

    8 v s h a r d w a r e s p e c i f i c a t i o n g u i d e h o m e / o ff i ce w i r i ng i n s t r uc t i o n s this section describes phone wiring for north america, and is provided as reference information for other countries and regions. Basic residential phone wiring looped wiring loop wiring is...

  • Page 13

    V s h a r d w a r e s p e c i f i c a t i o n g u i d e 9 demarcation point the demarcation point is the point of interconnection between the telephone company facilities and your building. Location: it is usually a box located inside the building, within 15 feet of the incoming phone wiring. In new...

  • Page 14

    1 0 v s h a r d w a r e s p e c i f i c a t i o n g u i d e home and home office wiring prior to adding your phone system all phones are connected together in a single loop (or in multiple loops). The phones are all wired to line 1. If you have two or more incoming lines, the phones can be wired to ...

  • Page 15

    V s h a r d w a r e s p e c i f i c a t i o n g u i d e 1 1 connecting to phone lines using one telephone line single-line phone cord — 2 pins using single-line phones single-line phone cords — 2 pins using a two-line phone two-line phone cord — 4 pins connecting to the rear panel wall jack to the p...

  • Page 16

    1 2 v s h a r d w a r e s p e c i f i c a t i o n g u i d e the system controls incoming lines and phones advantages • home phone system and office phone system are integrated together. • calls to the home can be forwarded to the office and vice versa. • the home phones have all the call handling ca...

  • Page 17

    V s h a r d w a r e s p e c i f i c a t i o n g u i d e 1 3 adding an extension block 1. Add an extension block next to the demarcation point. 2. Connect the house loops and the phone cable from the demarcation point to the posts of the extension block. D e 111 112 113 114 114 114 x x y to system ex...

  • Page 18

    1 4 v s h a r d w a r e s p e c i f i c a t i o n g u i d e connecting to the system 1. Use a single-line rj-11 phone cord to connect the demarcation point to the system’s l1. 2. Use a single-line rj-11 phone cord to connect the extension block to the system’s e4. 3. Use single-line rj-11 phone cord...

  • Page 19

    V s h a r d w a r e s p e c i f i c a t i o n g u i d e 1 5 s a fe t y a n d re g u l a to r y i n f o r m a t i o n safety precautions before using the system, please review and ensure the following safety instructions are adhered to: 1. Read, follow and retain instructions — all safety and operati...

  • Page 20

    V s h a r d w a r e s p e c i f i c a t i o n g u i d e 1 6 important notices ce compliance the product models listed below comply with the essential requirements of the european “radio and telecom terminal equipment” (r&tte) directive 1999/5/ec, and are for connection to regular telephone lines (ps...

  • Page 21

    V s h a r d w a r e s p e c i f i c a t i o n g u i d e 1 7 acta tia/eia/is-968a, fcc part 68 and ic cs-03 notice: the industry canada label identifies certified equipment. This certification means the equipment meets telecommunications network protective, operational and safety requirements as pres...

  • Page 22

    V s h a r d w a r e s p e c i f i c a t i o n g u i d e 1 8 icasa for all icasa license enquiries, please contact your south african authorized distributor for your phone system. Rohs compliance this equipment conforms with the reduction of hazardous substances (rohs) directive 2002/95/ec. The rohs ...