Tally T5023+ Programming Manual - page 119
Manual is about: Multi-functional flat bed printer
of
404
Standard commands
Print modes
T5023/5023+ - Programming Guide
109
Enable/Disable Double Character Height
Function:
All characters following this command are printed with double the normal height.
Parameters:
n = 0 deactivates the mode
n = 1 activates the mode
ESC
27
1B
w
119
77
(n)
n
n
ASCII character
Decimal
Hexadecimal