TANDBERG Telepresence T3 Installation Sheet

Other manuals for Telepresence T3: Assembly Manual
Manual is about: Tandberg Multi-Room Video System Assembly Guide

Summary of Telepresence T3

  • Page 1

    Page 1/22 tandberg telepresence t3 119076.02 telepresence t3 room requirements 12.08 room requirements the room requirements description presents the room dimensions requirements, weights, wall- and ceiling loads, power outlet requirements as well as the heating, ventilation and air-conditioning (hv...

  • Page 2

    P a g e 2 /2 2 ta n d b e r g telepresence t3 119076.02 telepresence t3 room requirements 12.08 ta n d b e r g telepresence t3 s y s t e m d im e n s io n s 1658 65 1 4 " t3 sy st em dimensions 2800 110 1 4 " 1650 65 " 1650 65 " 1500 59 " 2500 65 3 8 " 120 4 3 4 " 724 28 1 2 " 5 8 4800 189 ".

  • Page 3

    P a g e 3 /2 2 ta n d b e r g telepresence t3 119076.02 telepresence t3 room requirements 12.08 r o o m d e p t h r e q u ir e m e n t s o p t im a l a n d m a x im a l d e p t h 140 5 1 2 " 4600 181 1 8 " 4880 192 1 8 " 1015 40" 1000 39 3 8 " 1300 51 1 8 " centerline baseline optimal room depth 280...

  • Page 4

    P a g e 4 /2 2 ta n d b e r g telepresence t3 119076.02 telepresence t3 room requirements 12.08 ta n d b e r g telepresence t3 m in im u m r o o m d e p t h r e q u ir e m e n t s 140 5 1 2 " 4120 162 1 4 " 4400 173 1 4 " 1015 40" 1000 39 3 8 " 1300 51 1 8 " centerline baseline min. Room depth 2800 ...

  • Page 5

    P a g e 5 /2 2 ta n d b e r g telepresence t3 119076.02 telepresence t3 room requirements 12.08 m in im u m r o o m w id t h r e q u ir e m e n t s centerline min room width 4800 189 " 6645 261 " 5 8 922,5 36 " 3 8 922,5 36 " 3 8 85 3 8 3 " 6815 268 " 1 4 85 3 8 3 " observe that the room should not ...

  • Page 6

    P a g e 6 /2 2 ta n d b e r g telepresence t3 119076.02 telepresence t3 room requirements 12.08 ta n d b e r g telepresence t3 o p t im u m a n d m a x im u m r o o m h e ig h t 2360 92 7 8 " 190 7 1 2 " 2550 100 3 8 " optimal r oom heigh t note that the room is shown with the t elepresence t3 syste...

  • Page 7

    P a g e 7 /2 2 ta n d b e r g telepresence t3 119076.02 telepresence t3 room requirements 12.08 m in im u m r o o m h e ig h t r e q u ir e m e n t s 2360 92 7 8 " 40 1 5 8 " 2400 94 1 2 " minimum r oom heigh t note that the room is shown with the t elepresence t3 system installed..

  • Page 8

    P a g e 8 /2 2 ta n d b e r g telepresence t3 119076.02 telepresence t3 room requirements 12.08 m a x im u m r o o m h e ig h t 2360 92 7 8 " 290 11 3 8 " 2650 104 3 8 " maximum r oom heigh t note that the room is shown with the t elepresence t3 system installed..

  • Page 9: Hvac Requirements

    Page 9/22 119076.02 telepresence t3 room requirements 12.08 tandberg telepresence t3 hvac requirements the following hvac (heating, ventilation, air-conditioning) requirements apply to the tandberg telepresence t3: • power consumption system: 1725 w • power consumption table: 300 w • power consumpti...

  • Page 10: Hvac Requirements

    Page 10/22 tandberg telepresence t3 119076.02 telepresence t3 room requirements 12.08 centerline baseline 320 12 5 8 " 2247 88 1 2 " 2100 82 5 8 " 150 5 7 8 " 2025 79 3 4 " 675 26 5 8 " 2280 89 3 4 " make sure that hvac mounting neither conflicts with the ceiling lights positions nor the document ca...

  • Page 11: Acoustics Requirements

    Page 11/22 119076.02 telepresence t3 room requirements 12.08 tandberg telepresence t3 acoustics requirements it is essential to have a good acoustic environment for the system to provide the true telepresence experience. This means that there should be sufficient sound insulation to minimize noise f...

  • Page 12: Power Outlet Fuse

    Page 12/22 119076.02 telepresence t3 room requirements 12.08 tandberg telepresence t3 power outlet fuse requirements the following minimum power outlet fuse requirements apply to the tandberg telepresence t3: item watt placement fuse on/off switch t1 module × 3 2400 back wall a 1 presentation splitt...

  • Page 13: Electronic Versions Of

    Page 13/22 119076.02 telepresence t3 room requirements 12.08 tandberg telepresence t3 electronic versions of technical drawings the technical drawings on the following pages are also available in electronic formats as pdf, dwg and dxf. To obtain copies of these drawings, send an e-mail to tandberg@t...

  • Page 14

    P a g e 1 4 /2 2 119076.02 telepresence t3 room requirements 12.08 320 12 1 2 " 2247 88 1 2 " 2100 82 1 2 " 150 6" 2025 79 1 2 " 675 26 1 2 " 1000 39 1 2 " 1000 39 1 2 " 4930 194" 2240 88" centerline area where installation of aircondition should be avoided installation area for ceiling mounted docu...

  • Page 15

    P a g e 1 5 /2 2 119076.02 telepresence t3 room requirements 12.08 140 5 1 2 " 140 5 1 2 " 4600 181 1 8 " 85 3 3 8 " 85 3 3 8 " 111 4 3 8 " 1695 66 3 4 " 885 34 7 8 " 400 15 3 4 " 885 34 7 8 " 1885 74 1 4 " 2160 85" 570 22 1 2 " 760 29 7 8 " 829 32 5 8 " 87,5 3 3 8 " centerline 4 single power outlet...

  • Page 16

    P a g e 1 6 /2 2 119076.02 telepresence t3 room requirements 12.08 ta n d b e r g telepresence t3 140 5 1 2 " 140 5 1 2 " 4600 181 1 8 " 85 3 3 8 " 85 3 3 8 " 111 4 3 8 " 1695 66 3 4 " 885 34 7 8 " 400 15 3 4 " 885 34 7 8 " 1885 74 1 4 " 2160 85" 570 22 1 2 " 760 29 7 8 " 829 32 5 8 " 87,5 3 3 8 " c...

  • Page 17

    P a g e 1 7 /2 2 ta n d b e r g telepresence t3 119076.02 telepresence t3 room requirements 12.08 1115 44" 1112,50 44" 85 3 1 2 " 3512,50 138 1 2 " 140 5 1 2 " 140 5 1 2 " 4098,50 161 1 2 " 2250 88 1 2 " 740 29" 10 1 2 " 20 1" 2400 94 1 2 " 4600 181" centerline optional second row rear edge of foot ...

  • Page 18

    P a g e 1 8 /2 2 ta n d b e r g telepresence t3 119076.02 telepresence t3 room requirements 12.08 ta n d b e r g telepresence t3 2360 93" 955 37 1 2 " 625 24 1 2 " 945 37" 300 12" 1900 75" 2025 79 1 2 " 300 12" frame around area for insulation boards gap between the vertical lattices 300 - approx. 6...

  • Page 19

    P a g e 1 9 /2 2 ta n d b e r g telepresence t3 119076.02 telepresence t3 room requirements 12.08 2360 93" 2260 89" 2090 82 1 2 " 3056,70 120 1 2 " 3596,70 141 1 2 " 1485 58 1 2 " centerline area for mounting/changing led frame around area for insulation boards 04.11.08 01 t3 long structure 119087 d...

  • Page 20

    P a g e 2 0 /2 2 ta n d b e r g telepresence t3 119076.02 telepresence t3 room requirements 12.08 ta n d b e r g telepresence t3 a a 75 3" 2132 84" 3833 151" 98,50 4" 615 24" 1557 61 1 2 " 3757 148" 80 3" 1193 47" center line base openings base opening base opening structural element structual eleme...

  • Page 21

    P a g e 2 1 /2 2 ta n d b e r g telepresence t3 119076.02 telepresence t3 room requirements 12.08 50 2" 2000 78 3 4 " 2280 89 3 4 " 724 28 1 2 " 2550 100 3 8 " d optimal height / suspended ceiling picture center 20 3 4 " 69 2 3 4 " detail d scale 1 : 5 removable baseboard for access to outlets. Moun...

  • Page 22

    P a g e 2 2 /2 2 ta n d b e r g telepresence t3 119076.02 telepresence t3 room requirements 12.08 140 5 1 2 " 4600 181 1 8 " 85 3 3 8 " centerline on floor cable routing - transport cables from t3 power / av / lan video lan customers lan master panel fire emergency switch (controls fuse groups a,b a...