Tannoy CVS4 User Manual - Cvs4
CVS4
CVS4 data file // issue 1.09 // 18.01.10
Tannoy United Kingdom
T: 00 44 (0) 1236 420199
E: enquiries@tannoy.com
Tannoy Deutschland
T: 00 49 (180) 1111 881
E: anfragen@tannoy.com
Tannoy France
T: 00 33 (0) 1 7036 7473
E: ventes@tannoy.com
TC|Group Americas
T: 00 1 (519) 745 1158
E: info@tcgroup-americas.com
The Ceiling Speaker System shall consist of a 100mm (4.00") mineral loaded mid bass driver with coaxially mounted 19mm (0.75") high frequency unit and
passive frequency dividing network mounted in a vented, injection moulded, paintable front baffle in UL94V-0 ABS material.
The backcan shall be constructed of zinc plated steel. A recessed termination box shall be integrated with the backcan, a removable locking connector with
screw terminals for secure wire termination with "loop through" facility shall be provided. Strain relief will be provided by a clamping mechanism for use with
plenum rated cable or conduit. A safety ring is located on the rear of the backcan for a load bearing safety bond.
Performance of the ceiling speaker shall meet or exceed the following criteria: The system shall have a conical coverage pattern of 102 degrees (1kHz to
6kHz). Frequency response measured on axis shall be 77Hz -22kHz (-10dB from rated sensitivity, measured in an IEC baffle in an anechoic chamber) with
no equalization. Sensitivity shall be 87dB (1W @ 1m). Long term power handling capacity as defined in EIA-426B test shall be 40W, recommended amplifier
power 80W. The nominal system impedance shall be 6 Ohms (in low impedance setting).
The ceiling speaker shall be equipped with a 30W high performance line transformer for use in 70.7 or 100 Volt distributed audio systems with 30, 15, 7.5,
3.75 Watt taps available. An easily accessible rotary switch located on the front baffle shall be available for selecting transformer and low impedance
settings. A weather resistant perforated steel grille covers the transducer and switch.
Two support rails and one C-Ring shall be included with the ceiling monitor system. The front face diameter shall not exceed 213mm (8.39"), overall depth
from the front of the ceiling to the top of the safety loop shall not exceed 214.90mm (8.46"). The template cut out diameter shall be 180mm (7.09").
The Ceiling Monitor System shall be the.....CVS4.
*70 Volt only
Architectural specifications
CVS 4.qxp:Layout 1 21/1/10 10:22 Page 7