6
5. Feeding the cable through the heater assembly, pass the cable through the M25 cable gland and through the terminal box. Locate
the heater assembly onto the joining pieces of the body pole assembly. Secure in place with 3 X M8 x 20 button head socket screws,
placing M8 spring washers behind the heads of the screws.
M8 SPRING WASHER
3 OFF
M8 x 20 BUTTON HEAD
SOCKET SCREW
3 OFF
6. Connect the mains cable to the connector block and earth post as shown using ring terminals and keeping the link wires in place as
shown. Tighten the cable gland nut fully and replace the terminal box cover and tighten the screws fully to prevent water ingress.
PRE-WIRED
HEATERS SIDE
EARTH
GREEN/YELLOW
LIVE
BROWN
NEUTRAL
BLUE
7. Replace the side cover and check all screws in the body poles are fully tightened. Adjust the heaters to the desired positions and
perform any necessary electrical safety checks before switching on.
3
Kit Contents
HEATER ASSEMBLY
1 OFF
M8 x 20 BUTTON HEAD
SOCKET SCREW
6 OFF
M8 SPRING WASHER
6 OFF
BODY POLE (WITH
JOINING PIECES FITTED)
2 OFF
BASE PLATE
1 OFF