Taski swingo 1255B Power Manual - I25
41
I25
I24
I23
I22
I21
I20
I19
I18
tr
sv
sl
ro
pt
pl
no
nl
it
hu
fr
fi
es
en
de
da
cz
Beginning work
During these 5 minutes:
Always turn the keyswitch to the 0-position and remove the key from the
machine if you are going to be out of sight of the machine.
During these 5 minutes:
Cleaning method
Direct method:
Scrubbing and vacuuming in one pass.
Indirect working method:
Apply the cleaning solution (only scrubbing), afterwards scrubbing and
vacuuming.
The cleaning method is described in detail in the ”Method Card”. You can obtain
this from your TASKI partner.
Refilling the solution tank
A rattling noise from the pump indicates that the solution tank is empty.
End of operation
Variant: (Option 1255) Automatic brush lowering
Pedal brush unit (optional):
Drain the recovery tank / solution tank
The disposal of the dirty water or the cleaning solution must be carried out in
accordance with the appropriate national regulations.
Clean the recovery tank / solution tank
Caution:
Always wear non-slip shoes and appropriate work clothing while
working with this machine!
• Lower the squeegee.
• Switch on the keyswitch.
The indicators light up briefly.
• Lower the brush unit using either the brush unit button or brush unit pedal,
see page 39.
• First press the solution dosing control button,
and then the vacuum on.
The indicators light up briefly.
• Choose the volume of solution (+/- button for
volume control).
The chosen setting is displayed with green
lights.
• By gently pressing the speed control in the
direction of drive, the machine is set in to
motion.
The tools start to turn and the solution is fed
through the centre.
The machine switches itself off again after 5 minutes.
• no manipulations of any kind may be carried out on the brushes.
• the operator must remain within sight of the machine.
• only the squeegee may be cleaned from sucked-in or jammed objects.
• the operator may on ly leave the machine for the purposes of clearing the
area to be cleaned, but must remain in visual contact with the machine.
Caution:
Do not clean without solution, as it could cause floor damage.
• Stop cleaning.
• Refill the tank, see page 40.
• Stop the flow of solution.
• Drive a few metres so that the tools rotate further for a short time. You will
avoid dripping by doing this.
Very important when using contact pads!
• Press the brush unit button to raise the tool.
• To raise the tool, press down the pedal and lock
it in place.
• Drive on a few metres further in order to pick up the remaining dirty water.
• Raise the squeegee.
Allow the suction unit to continue running until
the rest of the dirty water has been sucked into
the hose.
• Switch off the suction unit first, and then the
keyswitch.
Always drain and clean the recovery tank every time you use the
machine.
If the dirty water is allowed to stand, unpleasant smells and
deposition of the dirt will take place after a few hours.
• Switch the machine off.
• Remove the drainage hose from its holder.
Open the red or blue cap situated near the handle and lower the
end of the hose slowly to drain the solution out.
• Switch the machine off.
• Open the lid until the self support locates on the tank wall.
• Remove the coarse dirt sieve (yellow), empty and clean it.
• Thoroughly rinse out the recovery tank with flowing water.
• Then thoroughly rinse out the solution tank with clean water.
• Check the float is functioning correctly and that the suction filter (yellow) is
clean.
In case of damage or soiling of the float and suction filter, please refer to
page 43.
• After draining and cleaning, screw the red and blue caps on again, and hang
the hoses from their holders again.