Tau speed 2 User Manual

Other manuals for speed 2: Use And Maintenance Manual
Manual is about: AUTOMATIONS FOR SLIDING GATES

Summary of speed 2

  • Page 1

    Automations for sliding gates automatizaciones para portones corredizos speed 2 - 5 - 8 use and maintenance manual manual de uso y mantenimiento.

  • Page 2

    The manufacturer reserves the right to modify or improve them without prior notice. Any inaccuracies or errors found in this manual will be corrected in the next edition. When opening the packing please check that the product is in excellent condition. Do not let children play anywhere there may be ...

  • Page 3

    Technical features of the b2 series art.P 400cnr nylon rack; art.P-400cps foundation counter plate complete with screws art.P-350... Geared motor mod. Speed 2 - 5 - 8 including: art.S-350f300140 nr. 2 end limit-sliding blocks (only for speed 5-8) materiales para lainstalacion art.P 400cnr cremallera...

  • Page 4: Finding The Site

    Finding the site localizacion de la ubicacion choose a position that is identical to the dotted area. Elegir una posicion análoga al area punteada. Preparing the base preparacion de la base dig comfortably wide foundations, at least 15 cm deep. Protect the cables with a sheath. 1 foundation counter ...

  • Page 5: Anchoring The Geared Motor

    Anchoring the foundation counter plates fijacion de la contraplaca de cimentacion 1.Once finished with the ditch, prepare the fundation counterplate by bending the clamps of the plate (see fig. Below) by the same spot where the cones are jointed to fasten the operator with screws. Fill the ditch wit...

  • Page 6: Fixing The Rack

    Tighten the screws (as shown in fig g) on both sides of the geared motor. Carry all cables across the holes obtained from the base of the foundation counter plate. Apretar los tornillos (tal como se indica en la fig.G1 - g2 ) en ambos lados del motorreductor. Pasar todos los cables a través de los a...

  • Page 7: Use of Manual Unlocking

    Position the blocks as shown in fig l, each one near the end of the rack. Moving the gate manually, position the blocks so they make contact with the micro switch lever just before the end of the rail mechanical stop intervenes; now tighten the screws. Colocar los patines como se indica en la fig. L...

  • Page 8: Speed

    Speed 5 speed 8 the mechanical friction clutch of speed 5 can be modified with a screwdriver regulating the rcm trimmer as shown in fig. P; on the contrary the mechanical friction clutch of speed 8 can be regulated manually with a key included in the kit of the geared motor as shown in fig q. El emb...

  • Page 9

    Electrical connections (speed 2 - 5 - 8) conexiones elÉctricas (speed 2 - 5 - 8) to connect remove the casing from the geared motor, the electrical components stand and only for speed 2 the cover of transformer, fig. R. Carry all cables across the holes obtained from the foundation' s base counter p...

  • Page 10

    Fig. U.

  • Page 11

    Fig. V.

  • Page 12: Terminal Board Connections

    Terminal board connections for slider cross speed 2 mec-10 110 v terminals inside transformer housing. 1 – 2 12v dc supply terminal 1 + terminal 2 – 3 – 4 12v dc 6ah dry battery input terminals 3 + terminal 4 - this battery guarantees power to panel for 24 hours with panel in waiting state or 20 min...

  • Page 13: Closing Is Needed

    7 & 8 not in use 9 & 10 electronic friction adjustment the system is highly sensitive to any variation in speed of travel due to any obstructions. Adjust as follows: off off maximum on off medium maximum off on medium minimum on on minimum setting travel (limits) time 1. Place jmp1 into “memo” bridg...

  • Page 14: Terminal Board Connections

    Terminal board connections for slider cross-speed 5 – speed 8 1 – 2 110 v ac 50 hz power supply 5 – 6 – 7 motor terminals: 5 – common, 6 – opening, 7 – closing. Capacitor between terminals 6 – 7 3 – 4 110 v 50 w max. Flashing output. The signal supplied is already modulated for direct use. Flashing ...

  • Page 15: Use

    2. On you can reverse directions both ways off you can reverse direction only when the gate is closing. 3. On during opening phase, the activation of photocell will shut down the gate movement until the detected obstacle is removed. During closure, the activation of photocell will cause the gate mov...

  • Page 16: Maintenance

    • mover la verja sólo cuando sea completamente visible; • mantenerse fuera del radio de acción de la verja, si ésta se halla en movimiento, esperar hasta que se haya detenido; • no dejar que niños o animales jueguen cerca de la verja; • no dejar que niños o personas incapacitadas usen el mando a dis...