Taylor 490 Original Operating Instructions - page 11
7
Model 490
Safety
130521
S
DO NOT allow untrained personnel to
operate this machine.
S
DO NOT operate the freezer unless all
service panels and access doors are
restrained with screws.
S
DO NOT remove any internal operating
parts (example: freezer door, beater,
scraper blades, etc.) unless all control
switches are in the OFF position.
Failure to follow these instructions may result in
severe personal injury from hazardous moving parts.
This unit has many sharp edges that can
cause severe injuries.
S
DO NOT put objects or fingers in the door
spout. This may contaminate the product
and cause severe personal injury from blade
contact.
S
USE EXTREME CAUTION when removing
the beater asssembly. The scraper blades
are very sharp.
Access to the service area of the unit is
restricted to persons having knowledge and practical
experience with the appliance, in particular as far as
safety and hygiene are concerned.
This freezer must be placed on a level
surface. Failure to comply may result in personal
injury or equipment damage.
Cleaning and sanitizing schedules are
governed by your state or local regulatory agencies
and must be followed accordingly. Please refer to
the cleaning section of this manual for the proper
procedure to clean this unit.
This machine is designed to maintain
product temperature under 41°F (5°C). Any product
being added to this machine must be below 41°F
(5°C). Failure to follow this instruction may result in
health hazards and poor freezer performance.
DO NOT obstruct air intake and discharge openings:
6” (152 mm) minimum air space is required on both
sides. It is recommended to place the rear of the unit
against the wall to prevent recirculation of warm air.
Failure to follow this instruction may cause poor
freezer performance and damage to the machine.
For Indoor Use Only: This unit is designed to
operate indoors, under normal ambient
temperatures of 70_-75_F (21_-24_C). The freezer
has successfully performed in high ambient
temperatures of 104_(40_C) at reduced capacities.
DO NOT run the machine without product. Failure to
follow this instruction can result in damage to the
machine.
NOISE LEVEL: Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of
1.0 meter from the surface of the machine and at a
height of 1.6 meters from the floor.