Taylor 702 Operating Instructions Manual - page 15
11
Models 702/741/772
Important: To the Operator
080324
Thermistor Control
The viscosity (thickness) of the product is controlled by
a temperature sensing device called the thermistor. To
achieve a thicker product, turn the control clockwise,
and turn the control counterclockwise to achieve a
thinner product. Allow the refrigeration system to cycle
on and off 2 or 3 times before an accurate consistency
can be evaluated.
Separate Hopper Refrigeration
System (SHR)
“Standby”
The Separate Hopper Refrigeration System (SHR)
and the Cylinder Temperature Retention System
(CTR) are standard features. This feature is referred
to as “STANDBY”. The SHR incorporates the use of a
separate small refrigeration system to maintain the
mix temperature in the hopper to below 40
_F. (4.4_C.)
This assures bacteria control. The CTR works with the
SHR to maintain a good quality product. During long
“No Sale” periods, it becomes necessary to warm the
product in the freezing cylinder to approximately 35
_F.
to 40
_F. (1.7_C. to 4.4_C.) to prevent overbeating and
product breakdown.
ALWAYS FOLLOW LOCAL HEALTH CODES.
Cleaning and sanitizing schedules are governed
by federal, state, or local regulatory agencies, and
must be followed accordingly. If the unit has a
“Standby mode”, it must not be used in lieu of
proper cleaning and sanitizing procedures and
frequencies set forth by the ruling health
authority.
CLEANING AND SANITIZING MUST BE
PERFORMED DAILY.
IMPORTANT: Make sure your hands are
sanitized before performing these instructions:
To activate SHR and CTR, place the air tube (end
without the hole) into the mix inlet hole.
Place the control switch in the “AUTO” position, and
turn the STANDBY switch to the “ON” position. The
unit will operate as a refrigerator for product in the
hopper and freezing cylinder.
To remove the unit from the “STANDBY” mode, place
the control switch in the “AUTO” position, and turn the
standby switch to the “OFF” position. The unit will
resume the normal operating mode.
When the unit cycles off, remove the hopper cover,
and place the feed tube in its original position.
Replace the hopper cover.