Taylor CD-i Operating manual - Setting Up And Welding
V‐4J
SETTING UP AND WELDING
10
Set up the control unit at the place of work,
ensuring that the mains switch is in the OFF
posi on. Ensure that this is done in line with the
notes and safety recommenda ons on pages 5 and
6 of this manual.
Plug the controller into the
correct mains AC supply. The
controller is rated for any single
phase AC voltage between 100
and 250VAC at 50Hz. Ensure
the correct plug is fi ed for
your supply in line with local/
na onal codes.
Connect the welding earth cable to the controller panel
mounted plug.
Note that the cable end plug has a peg which mates with a
key slot in the panel mounted socket.
IMPORTANT !
Secure the connector with a
clockwise turn un l it locks.
Failure to do this will result in
damage to the connector
during welding.
A ach the welding earth clamps to the work piece at
approximately 180° to each other. This will help to prevent
"Arc blow" when welding takes place. Prior to fi ng the
clamps, ensure that the contact area of the work piece is
free from rust, paint, grease etc. As this will result in a poor
welding connec on and poor results. Where possible, route
the earth cables away from the operator to prevent the operator being posi oned between
the run of the cables whilst opera ng the equipment.
Connect the welding pistol cable to the controller panel
mounted socket.
Note that the cable end plug has a peg which mates with
a key slot in the panel mounted socket.
IMPORTANT !
Secure the connector with
a clockwise turn un l it
locks. Failure to do this
will result in damage to
the connector during