Theben TR 610 top3 Manual - page 6
6
6. Technical data
Operating voltage:
230 V AC +10 % / –15 %
Frequency:
50–60 Hz
Standby:
0,4 W
Max switching capacity:
16 A (at 250 V, cos
ϕ
= 1)
switching capacity:
10 A (at 250 V, cos
ϕ
= 0,6)
Min. switching capacity:
10 mA/230 V AC
100mA/ 24 V AC/DC
Switch output:
switching of any phase is per-
mitted (TR 612 top3)
TR 610 top3:
suitable for switching SELV (Safe
Extra-Low Voltage)
Shortest switching time:
1 min
Switching accuracy:
accurate to the second
Protection rating:
IP 20 in accordance with EN
60529
Protection class:
II in accordance with
EN 60730-1 subject to designa-
ted installation
Operating temperature:
–30 °C … +55 °C
Power reserve:
10 years at +20 °C (without
Bluetooth OBELISK top3)
Time accuracy (typical):
±0,25 s/day (25 °C)
Rated impulse withstand voltage:
4 kV
Pollution degree:
2
Contact:
two way switch
Glow lamp load:
2600 W
Halogen lamp load:
2600 W
Fluorescent lamp load: uncorrected:
Series corrected:
parallel-corrected:
2600 VA
2600 VA
1300 VA (130 µF)
Compact fluorescent tubes (EVG):
1100 W
LED lamps (
50 W
LED lamps (> 2 W):
600 W
Bluetooth OBELISK top3:
– Protection rating:
– Temperature:
– Range:
IP 40
–30 °C to +55 °C
15 m on open air test site
L
The time switch display is only fully functional at tempera-
tures from +5 °C - +55 °C.
7. Contact
Theben AG
Hohenbergstr. 32
72401 Haigerloch
GERMANY
Tel. +49 7474 692-0
Fax +49 7474 692-150
Hotline
Tel. +49 7474 692-369
hotline@theben.de
Addresses, telephone numbers etc.