1 p/n: 4033180 serial no.: install date: sold by: hvac installer: please leave manual for homeowner the quest 185 cool is a split system dehumidifier with sensible cooling that is integrated into the heating and cooling system to provide the ultimate in comfort, health and property protection throug...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 2 www.Questhydro.Com info@questhydro.Com safety instructions .............................................................................................................3 specifications .................................
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 3 www.Questhydro.Com info@questhydro.Com safety instructions warning! This symbol means important instructions. Failure to heed them can result in serious injury or death. Read the installation, operation and maintena...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 4 www.Questhydro.Com info@questhydro.Com specifications side view front view 33” 25 1/2” 25 1/2” 10” dehumidifier part number: 4037391 blower: 406 cfm @ 0.0” wg 374 cfm @ 0.2” wg 348 cfm @ 0.4” wg power: 160 watts @ 8...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 5 www.Questhydro.Com info@questhydro.Com optional accessories 4028531 deh 3000r control (with remote) 4021475 merv 11 filter (16"x20"x2") 4027420 merv 11 filters 4-pack 4027424 merv 11 filters 12-pack 4028614 pump kit...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 6 www.Questhydro.Com info@questhydro.Com important precautions • the dehumidifier is designed to be installed indoors in a space that is protected from rain and flooding. • install the dehumidifier with enough space t...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 7 www.Questhydro.Com info@questhydro.Com condensing unit set up important precautions • the condensing unit is designed to be installed outdoors in a space that is protected from extreme weather (rain, wind, etc.). Do...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 8 www.Questhydro.Com info@questhydro.Com system requirements condensate water removal condensate drains by gravity via the drain port. Use 3/4” male npt pvc pipe. Route drain pipe to drain. Install a trap if possible....
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 9 www.Questhydro.Com info@questhydro.Com dehumidifier electrical requirements the dehumidifier plugs into a common grounded 115 vac outlet. The device draws 1.4 amps at 80°f and 60% rh and can be plugged into a shared...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 10 www.Questhydro.Com info@questhydro.Com 4033179 compressor cond. Relay cond. Relay coil 115 vac line neutral blk red brn wht blk brn red wht run cap. Wht blk blk 1 n l l n run cap. Blower 24vac signal from dehu. S c...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 11 www.Questhydro.Com info@questhydro.Com condensing unit & dehumidifier wiring line neutral dehu. Relay blower relay blower xfmr dehu. Relay coil blower relay coil defrost t-stat l. Press switch run cap. 24vac signal...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 12 www.Questhydro.Com info@questhydro.Com line set isolation — the following illustrations are examples of proper refrigerant line set isolation. Refrigerant line set — transition from vertical to horizontal refrigera...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 13 www.Questhydro.Com info@questhydro.Com when installing the line set: • make sure the lines are suitable for use with r410a. • do not crush the lines and always allow a minimum bend radius of 2 inches. • keep the en...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 14 www.Questhydro.Com info@questhydro.Com line set installation warning! Polyol ester (poe) oils used with hfc-410a refrigerant absorb moisture very quick- ly. It is very important that the refrigerant system be kept ...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 15 www.Questhydro.Com info@questhydro.Com line set installation caution! The dehumidifier is shipped from the factory pressurized with a charge of inert gas and with rubber plugs in the lines. Purge the inert gas from...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 16 www.Questhydro.Com info@questhydro.Com manifold gage set when checking the system charge, use a manifold gage set that features low loss anti-blow back fittings. Manifold gage set used with hfc-410a refrigerant sys...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 17 www.Questhydro.Com info@questhydro.Com 1. Remove the valve cores from the service ports on the liquid and gas line stubs using no-loss valve core removal tools. 2. Connect a 1/4” sae in-line tee to the gas line stu...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 18 www.Questhydro.Com info@questhydro.Com charging the system the condensing unit is pre-charged with 42 oz. Of hfc-410a refrigerant. The installer will add hfc-410a refrigerant for the dehumidifier and line set. 1. C...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 19 www.Questhydro.Com info@questhydro.Com a control must be used with the quest 185 cool. Quest offers the deh 3000 proprietary control. The deh 3000 allows homeowners to monitor and control relative humidity and prop...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 20 www.Questhydro.Com info@questhydro.Com controls a low voltage control must be used with the quest 185 cool. Basic control wiring control dehumidifier yellow yellow blue blue low voltage wiring green (or brown) fan ...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 21 www.Questhydro.Com info@questhydro.Com warning! Servicing the quest 185 cool with its high pressure refrigerant system and high voltage circuitry presents a health hazard which could result in death, se- rious bodi...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 22 www.Questhydro.Com info@questhydro.Com symptom possible reason troubleshooting procedure caution! Troubleshooting should be performed by a qualified hvac technician. Troubleshooting troubleshooting procedure for co...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 23 www.Questhydro.Com info@questhydro.Com troubleshooting (continued) symptom possible reason troubleshooting procedure troubleshooting procedure for performance related issues this method of diagnosis is used to func...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 24 www.Questhydro.Com info@questhydro.Com symptom possible reason troubleshooting procedure caution! Troubleshooting should be performed by a qualified hvac technician. Troubleshooting troubleshooting procedure for co...
1-877-420-1330 quest 185 cool installation, operation and maintenance instructions 25 www.Questhydro.Com info@questhydro.Com warranty limited warranty. Therma-stor, llc (“therma-stor”) warrants as follows: (i) the quest 185 cool dehumidifier (“product”) will be free of material defects in workmanshi...
1-877-420-1330 www.Questhydro.Com.