Summary of 1000 SERIES

  • Page 1

    User guide safety • installation & integration • operating instructions • maintenance • service 1000 series • bi1215 • 15" crescent ice maker right product. Right place. Right temperature. Since 1962..

  • Page 2

    User guide u-line.Com contents safety • installation & integration • operating instructions • maintenance • service intro safety safety and warning disposal and recycling installation environmental requirements electrical cutout dimensions product dimensions side by side installation water hookup an...

  • Page 3

    User guide introduction 1 u-line.Com welcome to u-line congratulations on your u-line purchase. Your product comes from a company with over five decades and three generations of premium modular ice making, refrigeration, and wine preservation experience. U-line continues to be the american leader, d...

  • Page 4

    User guide safety and warning 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service safety and warning notice please read all instructions before installing, operating, or servicing the appliance. Use this appliance for its intended purpose only and follow...

  • Page 5

    User guide disposal and recycling 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service disposal and recycling danger ! Risk of child entrapment. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so child...

  • Page 6

    User guide environmental requirements 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service environmental requirements this model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural ele...

  • Page 7

    User guide electrical 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service electrical warning ! Shock hazard — electrical grounding required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never rem...

  • Page 8

    User guide cutout dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cutout dimensions prepare site your u-line product has been designed for either free- standing or built-in installation. When built-in, your unit does not require additional...

  • Page 9

    User guide product dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service product dimensions 34-1/8" to 35-1/8" (867 mm to 892 mm) 14-15/16" (379 mm) 3-9/16" (91 mm) not including handle 23-1/4" (591 mm).

  • Page 10

    User guide side-by-side installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service side-by-side installation two units may be installed side-by-side. Cutout width for a side-by-side installation is the cutout dimension of a single unit times two. N...

  • Page 11

    User guide water hookup 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service water hookup prepare plumbing the water valve uses a standard 1/4" (6.35 mm) compression fitting. U-line recommends using accessory water hook up kit – part # waterhookup. The ki...

  • Page 12

    User guide water hookup 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service 3. Locate water valve inlet. 4. Break away filler feature in bushing with flat screwdriver. 5. Thread water line through back panel hole (with bushing). 6. Locate water valve inl...

  • Page 13

    User guide anti-tip bracket 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service anti-tip bracket 1. Slide unit out so screws on top of unit are easily accessible. 2. Remove the two screws from the opposite side of the hinge assembly using a t-25 torx dri...

  • Page 14

    User guide general installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service general installation leveling information 1. Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown. 2. If the unit is not...

  • Page 15

    User guide grille - plinth installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service grille - plinth installation removing and installing grille warning ! Disconnect electric power to the unit before removing the grille. When using the unit, the g...

  • Page 16

    User guide door swing 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service door swing units have a zero clearance for the door to open 90°, when installed adjacent to cabinets. Stainless steel and black and white models require 2-1/8" (54 mm) door clearan...

  • Page 17

    User guide door stop 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service door stop your u-line unit was shipped to you with the optional 90° pin(s). (models that are 15" wide include 1 pin. Models that are 24" wide include 2 pins.) the unit’s door will o...

  • Page 18

    User guide door adjustments 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service door adjustments door alignment and adjustment align and adjust the door if it is not level or is not sealing properly. If the door is not sealed, the unit may not cool prope...

  • Page 19

    User guide door adjustments 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service remove bottom hinge: 1. Remove bottom hinge from cabinet. 2. Remove corresponding screws on opposite side of cabinet. On some models there may be a nut behind one or both scr...

  • Page 20

    User guide first use 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service first use all u-line controls are preset at the factory. Initial startup requires no adjustments. Notice u-line recommends discarding the ice produced during the first two to three ...

  • Page 21

    User guide ice 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service ice ice maker operation when the ice bucket is full, the ice making mechanism will shut off. However, the refrigeration system will continue to cool and maintain the ice supply. Notice do...

  • Page 22

    User guide ice 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service ice maker adjustment ice cube thickness adjustment interval - as required on ice maker equipped models, adjust the cube size by changing water amount injected into the ice maker assembly ...

  • Page 23

    User guide airflow and product loading 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service airflow and product loading notice the unit requires proper airflow to perform at its highest efficiency. Do not block the front grille at any time, or the unit wi...

  • Page 24

    User guide cleaning 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cleaning exterior cleaning vinyl clad (black or white) models clean surfaces with a mild detergent and warm water solution. Do not use solvent-based or abrasive cleaners. Use a soft ...

  • Page 25

    User guide cleaning 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service defrosting manual defrost models this unit is a manual defrost model and will require occasional defrosting. When there is build-up of 1/4" (6 mm) or more of frost, manually defrost ...

  • Page 26

    User guide cleaning condenser 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cleaning condenser interval - every six months to maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary. Depe...

  • Page 27

    User guide extended non-use 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service extended non-use vacation/holiday, prolonged shutdown the following steps are recommended for periods of extended non-use: 1. Remove all consumable content from the unit. 2. ...

  • Page 28

    User guide troubleshooting 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service troubleshooting before calling for service if you think your u-line product is malfunctioning, read the control operation section to clearly understand the function of the con...

  • Page 29

    User guide troubleshooting 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service checking product temperature to check the actual product temperature in the unit: 1. Partially fill a plastic (nonbreakable) bottle with water. 2. Insert an accurate thermomet...

  • Page 31

    User guide warranty 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service defective parts be returned, at your expense, to u- line’s factory in milwaukee, wisconsin, for inspection. Any action by you for breach of warranty must be commenced within one year...