U-Line 3045CLR Quick Start Manual

Other manuals for 3045CLR: User Manual

Summary of 3045CLR

  • Page 1

    Quick start guide modular 3000 series • 3045clr • 220-240 v / 50 hz.

  • Page 2

    Quick start guide u-line.Com welcome to u-line congratulations on your u-line purchase. Your product comes from a company with over five decades and three generations of premium modular ice making, refrigeration, and wine preservation experience. U-line continues to be the american leader, deliverin...

  • Page 3

    Quick start guide u-line.Com contents 1 model list 2 safety and warning 3 environmental requirements 4 electrical 4 water hookup 6 drain 8 door swing 8 general installation 9 integrated panel installation 11 control quick guide 11 first use 11 ice 13 sabbath mode 13 warranty.

  • Page 4

    Quick start guide 1 u-line.Com model list this guide provides the basics to get you started. Looking for more information? Visit u-line.Com to view detailed user guides for all u-line products. Clear ice machines* u-3045clrint-00b u-3045clrint-40b *unit shown with wood panel not included with unit. ...

  • Page 5

    Quick start guide 2 u-line.Com safety and warning notice please read all instructions before installing, operating, or servicing the appliance. Safety alert definitions throughout this guide are safety items labeled with a danger, warning or caution based on the risk type: danger ! Danger means that...

  • Page 6

    Quick start guide 3 u-line.Com caution ! Use care when moving and handling the unit. Use gloves to prevent personal injury from sharp edges. If your model requires defrosting, do not use medical devices or other means to accelerate the defrosting process. Do not use an ice pick or other sharp instru...

  • Page 7

    Quick start guide 4 u-line.Com electrical warning ! Shock hazard — electrical grounding required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter. ...

  • Page 8

    Quick start guide 5 u-line.Com caution ! Do not use any plastic water supply line. The line is under pressure at all times. Plastic may crack or rupture with age and cause damage to your home. Do not use tape or joint compound when attaching a braided flexible water supply line that includes a rubbe...

  • Page 9

    Quick start guide 6 u-line.Com 8. Install retaining clip. Drain model numbers including “-00” or “-07” do not include a factory installed drain pump. Model numbers including “-40” or “-47” include a factory installed drain pump. Drain connection caution ! If your u-line unit did not come with a fact...

  • Page 10

    Quick start guide 7 u-line.Com caution ! Failure to connect water supply or drain line connections properly can result in personal injury and property damage. Gravity drain connections must be routed downward from the rest of the unit at the rate of 1/4" per foot (1 cm per 50 cm). Factory installed ...

  • Page 11

    Quick start guide 8 u-line.Com door swing for models that are installed adjacent to a wall, 1/4" (6 mm) clearance is recommended from wall on hinge side to allow the door to open 90°. Allow for additional space for any knobs or pulls installed on the integrated panel/ frame. Units have a zero cleara...

  • Page 12

    Quick start guide 9 u-line.Com integrated panel installation 1. Fully open door. 2. Starting at corner, pull gasket away from door. 3. Continue to pull gasket free from gasket channel. 4. Upon removal, lay gasket down on a flat surface. 5. The panel should be aligned with the outside edge (opposite ...

  • Page 13

    Quick start guide 10 u-line.Com 9. Using a phillips screwdriver, place one screw into each of the 6 pilot holes and screw down. Do not over tighten screws. 10.Ensure the screws sit flush against the bottom of the channel. 11.Remove clamps from door. Notice if panel requires additional adjustment aft...

  • Page 14

    Quick start guide 11 u-line.Com control quick guide actual display: first use all u-line controls are preset at the factory. Initial startup requires no adjustments. Notice u-line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale ...

  • Page 15

    Quick start guide 12 u-line.Com 12.7 mm) in depth. A fuller cube with less of a dimple results in a thicker ice bridge. As the ice bridge thickens, the tendency for the cubes to stay together as a slab increases. A bridge thicker than 1/8" (3.2 mm) may cause cubes to overfill the ice bucket. Your cl...

  • Page 16

    Quick start guide 13 u-line.Com l sabbath mode u-line clear ice machine models are star-k certified and can be used during the sabbath. View a full list of star-k certified u-line units at www.Star-k.Org. To prepare the unit for the sabbath: 1. Press and hold the until the unit turns off. 2. No new ...

  • Page 17

    Quick start guide 14 u-line.Com (except during the first 30 days from the date of installation); defrosting the product; adjusting the controls; door reversal; and cleaning the condenser. 5. U-line products are designed to operate in ambient temperatures between 10°c and 32°c unless otherwise noted ...