U-Line 3045CLR User Manual

Other manuals for 3045CLR: Quick Start Manual

Summary of 3045CLR

  • Page 1

    User guide safety • installation & integration • operating instructions • maintenance • service modular 3000 series • 3045clr • 45 cm clear ice machine right product. Right place. Right temperature. Since 1962..

  • Page 2

    User guide u-line.Com contents safety • installation & integration • operati ng instructions • maintenance • service intro safety safety and warning disposal and recycling installation environmental requirements electrical cutout dimensions product dimensions side by side installation water hookup d...

  • Page 3

    User guide introduction 1 u-line.Com welcome to u-line congratulations on your u-line purchase. Your product comes from a company with over five decades and three generations of premium modular ice making, refrigeration, and wine preservation experience. U-line continues to be the american leader, d...

  • Page 4

    User guide safety and warning 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service safety and warning notice please read all instructions before installing, operating, or servicing the appliance. Safety alert definitions throughout this guide are safety i...

  • Page 5

    User guide safety and warning 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service caution ! Use care when moving and handling the unit. Use gloves to prevent personal injury from sharp edges. If your model requires defrosting, do not use medical devices ...

  • Page 6

    User guide disposal and recycling 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service disposal and recycling danger ! Risk of child entrapment. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so child...

  • Page 7

    User guide environmental requirements 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service environmental requirements this model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural ele...

  • Page 8

    User guide electrical 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service electrical warning ! Shock hazard — electrical grounding required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never rem...

  • Page 9

    User guide cutout dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cutout dimensions prepare site your u-line product has been designed exclusively for a built-in installation. When built-in, your unit does not require additional air space ...

  • Page 10

    User guide product dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service product dimensions 33-11/16" to 34-11/16" (856 mm to 881 mm) 24" (610 mm) (includes 3/4" [20 mm] integrated panel) 17-3/4" (450 mm) 3-5/8" to 4-5/8" (92 mm to 118 mm).

  • Page 11

    User guide side-by-side installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service side-by-side installation other site requirements side-by-side installation units must operate from separate, properly grounded electrical receptacles placed accordi...

  • Page 12

    User guide water hookup 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service water hookup prepare plumbing the water valve uses a standard 1/4" (6.35 mm) compression fitting. U-line recommends using accessory water hook up kit – part # waterhookup. The ki...

  • Page 13

    User guide water hookup 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service 3. Locate water valve in the front of the unit and thread water supply line through. Notice route the water supply line through the unit so it does not come into contact with any...

  • Page 14

    User guide drain 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service drain model numbers including “-00” or “-07” do not include a factory installed drain pump. Model numbers including “-40” or “-47” include a factory installed drain pump. Drain connecti...

  • Page 15

    User guide drain 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service factory installed drain pump if your drain line will run up to a stand pipe, disposal or spigot assembly, or does not otherwise meet the requirements for a gravity drain, you may have o...

  • Page 16

    User guide drain pump 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service drain pump notice please read this instruction completely before attempting to install or operate the unit. Improper hook-up can result in substantial property damage! If you are u...

  • Page 17

    User guide drain pump 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service installation procedure warning ! To prevent accidental electrocution, make certain that the floor surfaces surrounding the unit are dry whenever power/electricity is removed from, ...

  • Page 18

    User guide drain pump 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service warning ! The back panel serves as a guard. Do not put your hands inside the ice machine cabinet or attempt to touch any components except the discharge tube during testing. Cautio...

  • Page 19

    User guide anti-tip bracket 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service anti-tip bracket caution ! The anti-tip bracket must be installed to prevent the unit from tipping when doors are fully opened or excess weight is placed on the front of the ...

  • Page 20

    User guide general installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service general installation 1. Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown. 2. If the unit is not level, remove grille...

  • Page 21

    User guide integrated panel dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service integrated panel dimensions integrated panel notice due to differences in surrounding cabinetry the panel may not perfectly align with door. The procedure below is...

  • Page 22

    User guide integrated panel dimensions 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service handleless integrated door panel the following procedure is designed to provide a finished, handleless solid panel for an 18" (450 mm) door that seamlessly integra...

  • Page 23

    User guide integrated panel dimensions 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service handleless integrated panel dimensions 3/4" (20 mm) 28-13/16" (732 mm) 2-3/4" (70 mm) 2-3/4" 70 mm r 5/8" (r 16 mm) 1/8" (3 mm) 1/4" (6 mm) wooden insert notch dep...

  • Page 24

    User guide integrated panel dimensions 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service extended integrated panel notice due to differences in surrounding cabinetry the panel may not perfectly align with door. The procedure below is designed to provid...

  • Page 25

    User guide integrated panel dimensions 5 u-line.Com safety • installation & integration • operating instructions • maintenance • service 3-5/16" (89 mm) to 4-5/16" (114 mm) u-line unit u-line unit integrated panel integrated panel/integrated frame front side front side 3-5/16" (89 mm) to 4-5/16" (11...

  • Page 26

    User guide integrated panel dimensions 6 u-line.Com safety • installation & integration • operating instructions • maintenance • service extended integrated panel dimensions back surface must have ample flat surface to mount integrated panel flat and without interference 3/4" (20 mm) integrated pane...

  • Page 27

    User guide integrated grille - plinth dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service integrated grille - plinth dimensions prepare and install integrated grille (plinth strip/base fascia) 1. Use the dimensions provided in the diagram to c...

  • Page 28

    User guide integrated panel installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service integrated panel installation 1. Fully open door. 2. Starting at corner, pull gasket away from door. 3. Continue to pull gasket free from gasket channel. 4. Upon...

  • Page 29

    User guide integrated panel installation 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service 11.Remove clamps from door. Notice if panel requires additional adjustment after removing clamps, slightly loosen each screw and adjust panel as necessary. Tight...

  • Page 30

    User guide grille - plinth installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service grille - plinth installation removing and installing grille (plinth strip/base fascia) warning ! Disconnect electrical current to the unit before removing the gri...

  • Page 31

    User guide door swing 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service door swing for models that are installed adjacent to a wall, 1/4" (6 mm) clearance is recommended from wall on hinge side to allow the door to open 90°. Allow for additional space ...

  • Page 32

    User guide door stop 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service door stop your u-line unit was shipped to you with the optional 90° pin. Your unit’s door(s) will open 115° straight from the factory. If you would like the door stop at 90° follow ...

  • Page 33

    User guide door adjustments 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service door adjustments door alignment and adjustment align and adjust the door if it is not level or is not sealing properly. If the door is not sealed, the unit may not cool prope...

  • Page 34

    Door adjustments 2 user guide safety • installation & integration • operating instructions • maintenance • service u-line.Com 3. Using t-25 torx bit loosen screw #1 and remove screw #2 on top and bottom hinge. Slide and remove the door from unit. Completely remove screw #1 on top and bottom. 4. Remo...

  • Page 35

    User guide first use 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service first use all u-line controls are preset at the factory. Initial startup requires no adjustments. Notice u-line recommends discarding the ice produced during the first two to three ...

  • Page 36

    User guide control operation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service control operation u-select ® control digital display the 3000 series units are controlled by a feature rich, advanced oled display control unit. The control panel allows adj...

  • Page 37

    User guide control operation 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service 3000 series - customer menu 1. To access the customer menu hold for 5 seconds. 2. Press or to scroll through available selections. 3. Press to enter selected sub-menu. 4. To...

  • Page 38

    User guide control operation 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service languages the u-line 3000 series of models supports a number of display languages including english, spanish, french, german and italian. 1. To change display language selec...

  • Page 39

    User guide control operation 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service clean cycle a clean cycle can be initiated through this menu. Once the cleaning cycle starts, the cycle cannot be stopped until complete. To initiate a clean cycle, select “...

  • Page 40

    User guide control operation 5 u-line.Com safety • installation & integration • operating instructions • maintenance • service help to access the help menu, select “help” from the customer menu. Press or to scroll through available information. To return to the customer menu, press to select “return...

  • Page 41

    User guide ice 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service ice ice cube thickness adjustment notice ice thickness adjustment should only be made one increment at a time. Allow ice maker production to stabilize for 24 hours before rechecking ice t...

  • Page 42

    User guide ice 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service ice adjust adjust ice thickness as follows: 1. Press and hold for 5 seconds to enter the customer menu. 2. Press to select “ice adjust”. 3. Press . The selection will begin to flash. 4. P...

  • Page 43

    User guide sabbath mode 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service l sabbath mode u-line clear ice machine models are star-k certified and can be used during the sabbath. View a full list of star-k certified u-line units at www.Star-k.Org. To pr...

  • Page 44

    User guide airflow and product loading 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service airflow and product loading notice the unit requires proper airflow to perform at its highest efficiency. Do not block the front grille at any time, or the unit wi...

  • Page 45

    User guide cleaning 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cleaning exterior cleaning stainless models stainless door panels and handles can discolor when exposed to chlorine gas, pool chemicals, saltwater or cleaners with bleach. Keep your ...

  • Page 46

    User guide cleaning 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service use only u-line ice machine cleaner (part no. 37050), available from your dealer or direct from your local parts distributor. To locate a parts distributor near you, visit www.U-line...

  • Page 47

    User guide cleaning 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service 9. When water begins flowing over the evaporator (approximately 3 minutes), pour 1 packet of clr cleaner into the water trough. The cleaning process will last approximately 45 minute...

  • Page 48

    User guide cleaning condenser 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cleaning condenser interval - every six months to maintain operational efficiency, keep the front grille (plinth strip/base fascia) free of dust and lint, and clean the con...

  • Page 49

    User guide extended non-use 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service extended non-use vacation/holiday, prolonged shutdown the following steps are recommended for periods of extended non-use: 1. Remove all consumable content from the unit. 2. ...

  • Page 50

    User guide troubleshooting 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service troubleshooting before calling for service if you think your u-line product is malfunctioning, read the control operation section to clearly understand the function of the con...

  • Page 51

    User guide troubleshooting 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service error notification the 3000 model series continuously monitors a series of inputs and parameters to ensure proper and efficient operation of your unit. Should the system detec...

  • Page 52

    User guide warranty 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service warranty u-line corporation limited warranty products outside the united states and canada 1. U-line corporation (“u-line”) warrants each u-line product to be free from defects in ma...

  • Page 53

    User guide warranty 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service installation of the product or from any other cause whatsoever, whether based on warranty (express or implied) or otherwise based on contract, tort, or any other theory of liability....

  • Page 54

    User guide wire diagram 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service wire diagram 42353_a wiring diagram green w/yellow (ground) waste water pump jumper plug without p60 waste pump green w/yellow (ground) black white pink (115v) pink (115v) pink h...

  • Page 55

    User guide product liability 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service product liability important note: service or repairs must not be performed on any unit suspected to be involved in a property damage situation. If a unit has been altered or...

  • Page 56

    User guide warranty claims 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service warranty claims the following information defines the parameters for filing a warranty claim: • valid serial number needed • valid model number needed • narda (or equivalent) ...

  • Page 57

    User guide ordering replacement parts 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service ordering replacement parts parts may be ordered on-line, by fax or on the phone. See our contact information below: www.U-lineservice.Com (with service login) fax n...

  • Page 58

    User guide system diagnosis guide 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service system diagnosis guide refrigeration system diagnosis guide system condition suction pressure suction line compressor discharge condenser capillary tube evaporator watt...

  • Page 59

    User guide compressor specifications 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service compressor specifications danger ! Electrocution can cause death or serious injury. Burns from hot or cold surfaces can cause serious injury. Take precautions when s...

  • Page 60

    User guide troubleshooting - extended 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service troubleshooting - extended specific errors and issues the technically advanced diagnostic capabilities of the electronic controls utilized on the 3000 series units ...

  • Page 61

    User guide troubleshooting - extended 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service troubleshooting guide concern potential causes suggested remedy no display or interior lights unit may be in sabbath mode hold for 5 seconds to turn off sabbath mod...

  • Page 62

    User guide troubleshooting - extended 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service main control the main control board is very robust and is rarely the cause of system issues. It is important to fully diagnose the board for any suspected failures ...

  • Page 63

    User guide control operation - service 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service control operation - service review actual temps review error log relay status relay toggle inputs o utputs offsets self test differentials set points factory defau...

  • Page 64

    User guide control operation - service 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service service menu in addition to a feature rich customer menu, the 3000 series also offers a service menu with the ability to fine tune and monitor unit operation. To i...

  • Page 65

    User guide control operation - service 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service to access all errors follow the steps below. 1. Press to select “all errors”. 2. Press . 3. Press and to scroll through available information. To clear the error l...

  • Page 66

    User guide control operation - service 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service to access relay toggle 1. Press to select “relay toggle”. 2. Press . 3. Press and to scroll through each relay or dc output. 4. Press to toggle. To exit the relay ...

  • Page 67

    User guide control operation - service 5 u-line.Com safety • installation & integration • operating instructions • maintenance • service offsets notice customer care must be notified and approve of any changes to the differential before they are made. Failure to notify customer care will void the wa...

  • Page 68

    User guide control operation - service 6 u-line.Com safety • installation & integration • operating instructions • maintenance • service differentials notice customer care must be notified and approve of any changes to the differential before they are made. Failure to notify customer care will void ...

  • Page 69

    User guide control operation - service 7 u-line.Com safety • installation & integration • operating instructions • maintenance • service to access re-select model 1. Press to select “re-select model”. 2. Press . To alter model setting 3. Press to select “model=” and press . “model” will begin to fla...

  • Page 70

    User guide thermistor 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service thermistors thermistors are used for various temperature readings. Thermistors provide reliable temperature readings using a resistance which varies based on surrounding temperatur...

  • Page 71

    User guide defrost 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service defrost these models have no defrost options..