    0513 ih-1027 page 1 of 11 before operating this stapler familiarize yourself with the safety warnings and instructions in this manual. Keep these instructions with the stapler for future reference. If you have any questions, contact uline at 1-800-295-5510. Warning stapler specifications dimensions:...

  • Page 2: Safety Instructions

    0513 ih-1027 page 2 of 11 safety instructions general safety 1. Read the manual and understand all safety instructions before operating the stapler. If you have questions, contact uline at 1-800-295-5510. 2. Never use flammable gases as a power source for the stapler. Only use filtered, compressed a...

  • Page 3

    0513 ih-1027 page 3 of 11 safety instructions continued loading the stapler 1. Disconnect the air supply. 2. Pull the pusher back until it stops on pusher pivots. Rotate pusher to position. (see figure 1) 3. Insert 2 sticks of appropriate staples into the magazine. Let the sticks slide forward to th...

  • Page 4

    0513 ih-1027 page 4 of 11 safety instructions continued clinch adjustment use 2.5 mm allen wrench and turn collar through window clockwise to tighten clinch. (see figure 6) depth adjustment 1. Loosen front screw with a 6 mm allen wrench. (see figure 7) 2. Push the body up and adjust to the desired d...

  • Page 5: Operating Instructions

    0513 ih-1027 page 5 of 11 operating instructions 1. Protect your eyes and ears. A. Wear safety glasses with side shields b. Wear hearing protection. C. Ensure that anyone in the vicinity wears safety protection. 2. To prevent accidental injuries, never place a hand or any other body part in the stap...

  • Page 6

    0513 ih-1027 page 6 of 11 operating instructions continued clearing a jam 1. Disconnect air supply. 2. Pull pusher back and rotate to a locked position. (see figure 11) problem cause remedy air leak from trigger o-ring on valve or on tube is damaged. Replace o-ring. Air leak from exhaust port o-ring...

  • Page 7

    0513 ih-1027 page 7 of 11 operating instructions continued teeth replacement 1. Loosen screws and nut with an 8 mm wrench and 4 mm allen wrench. (see figure 13) 2. Remove the magazine assembly. (see figure 14) 3. Loosen screws with 3 mm allen wrench. (see figure 15) 4. Change teeth one at a time to ...

  • Page 8

    0513 ih-1027 page 8 of 11 driver replacement 1. Disconnect the air supply. 2. Loosen screw and nut with a 8 mm spanner wrench and a 4 mm allen wrench. (see figure 16) 3. Remove the magazine assembly. (see figure 17) 4. Loosen the set screw with a 3 mm allen wrench to unlock the adjusting rod. Operat...

  • Page 9

    0513 ih-1027 page 9 of 11 pusher spring replacement 1. Loosen the screws and nut with a 8 mm spanner wrench and a 4 mm allen wrench. (see figure 21) 2. Remove the magazine assembly. (see figure 22) 3. Pull the pusher back until it stops on the rod, then rotate the pusher to position. (see figure 23)...

  • Page 10

    0513 ih-1027 page 10 of 11 valve and tube o-ring replacement 1. Loosen screws with a flat screwdriver. (see figure 27) 2. Remove spring with needle nose pliers. (see figure 28) c-ring valve and tube operating instructions continued 3. Remove c-ring with c-ring pliers. (see figure 29) 4. Remove valve...

  • Page 11

    0513 ih-1027 page 11 of 11 piston replacement 1. Remove screws and nut with 8 mm spanner wrench and 4 mm allen wrench. (see figure 31) 2. Remove magazine assembly. (see figure 32) 3. Loosen set screw with a 3 mm allen wrench to unlock the adjusting rod. 4. Slide linkage mechanism and adjusting rod s...