  • Page 1

    2 -wire intercom system dt591/592 user manual dt-eng-591/592-v1 100s503 dt591 dt592.

  • Page 2

    Contents 1.Parts and functions............................................................................................. 1 2.Terminal descriptions .......................................................................................... 1 3.Specifications ...........................................

  • Page 3

    -1- 1.Parts and functions rainy cover camera lens night view led speaker nameplate call button microphone 90 mm 176 mm 23 mm 2.Terminal descriptions bus pl s1+ s2+ s- 1 2 on 1 2 on mic adjustment lock control jumper doorstation code dip main connect port 1 2 3 spk adjustment note: dt592 has two call...

  • Page 4

    -2- • lock control jumper: to select the lock type: see 5.2.1 , 5.2.2 • doorstation code dip: total 4 doorstations can be supported,see 6.1 • main connect port: to connect the bus line and the electronic locks. • bus: connect to the bus line, no polarity. • pl: external lock power input, connect to ...

  • Page 5

    -3- 4.2 mounting with rainy cover 160-165cm 1 2 1 2 3 4 4.3 placing name label move the plastic cover away to open the transparent name label cover, insert a name paper, then put the plastic cover back to the panel. Name label 1 2 on.

  • Page 6

    -4- 4.4 adjusting camera angle 5.1 basic connection use a screwdriver to loosen the screw and then adjust the angle of the camera ,then fix the screw. 5.System wiring and connections 1 2 o n - + l1 l2 pl s1+ s2+ s- ac~ monitor dps ps4.

  • Page 7

    -5- 5.2 electric lock connection 5.2.1 door lock controlled with internal power connect one lock connect two locks note: 1. Electronic lock of power-on-to-unlock type should be used. 2. The door lock is limited to 12v, and holding current must be less than 250ma. 3. The door lock control is not time...

  • Page 8

    -6- 1 2 o n 1 2 3 - - + + bus pl s1+ s2+ s- take off the jumper take off the jumper 1 2 o n 1 2 3 - - + + bus pl s1+ s2+ s- power supply power supply - + lock #2 lock #1 connect one lock connect two locks 5.2.3 how to setup the unlock parameter in monitor monitor intercom setup exit outdoor tone -- ...

  • Page 9

    -7- 5.3 multi doorstations connection 85~260vac dps ps5 monitors 1 2 o n l1 l2 pl s1+ s2+ s- 1 2 o n l1 l2 pl s1+ s2+ s- 1 2 o n l1 l2 pl s1+ s2+ s- 1 2 o n l1 l2 pl s1+ s2+ s- 1 2 on 1 2 on 1 2 on 1 2 on 1# camera id=00 id=10 id=01 id=11 2# camera 3# camera 4# camera dbc4 a b c d bus.

  • Page 10

    -8- 5.4.1 basic in-out wiring mode 5.4 multi monitors connection id=00 1 2 on code=0, dip-6=off code=14, dip-6=off code=15, dip-6=on 1 2 3 4 5 6 on 1 2 3 4 5 6 on 1 2 3 4 5 6 on 85~260ac dps ps5 monitor monitor monitor.

  • Page 11

    -9- 5.4.2 with dbc-4 wiring mode hi hi monitor monitor monitor monitor monitor monitor monitor monitor dbc-4 a b c d in out dbc-4 a b c d in out 85~260ac dps ps5 1 2 3 4 5 6 on 1 2 3 4 5 6 on 1 2 3 4 5 6 on 1 2 3 4 5 6 on code=15, dip-6=on code=13, dip-6=on code=3, dip-6=on code=1, dip-6=on 1 2 3 4 ...

  • Page 12

    -10- 6.Setup 6.2 dip switches settings of monitor 6.1 dip switches settings of doorstation total 2 bits on the dip switches can be configured.The switches can be modified etther before or after installation. Bit state descriptions default setting, id = 0(00), set to the first door station. Id = 1(10...

  • Page 13

    -11- bit state user code bit state user code bit state user code code=0 code=11 code=22 1 2 3 4 5 6 on code=1 1 2 3 4 5 6 on code=12 1 2 3 4 5 6 on code=23 1 2 3 4 5 6 on code=2 1 2 3 4 5 6 on code=13 1 2 3 4 5 6 on code=24 1 2 3 4 5 6 on code=3 1 2 3 4 5 6 on code=14 1 2 3 4 5 6 on code=25 1 2 3 4 ...

  • Page 14

    -12- 6.3 notices name discription useage ps5-24v power supply,85~260vac input,24vdc/3a output,10 din modeules connect with multi doorstations or multi monitors(up to 2 or above) ps4-24v power supply,85~260vac input,24vdc/1a output,for basic kit only,4 din modules connect with one doorstation and one...

  • Page 15

    -13- 7.Cables requirements the maximum distance of the wiring is limited in the dt system. Using different cables may also effect the maximum distance the system can reach. When monitor quantity cable usage a b c twisted cable 2x0.75 mm 2 60 60 30 twisted cable 2x1 mm 2 80 80 40 when monitor quantit...