V-Tec DT591 User Manual

Other manuals for DT591: User Manual
Manual is about: 2 -Wire Intercom System

Summary of DT591

  • Page 1

    2 -wire intercom system dt591/592 user manual dt-eng-591/592-v1 100s719 dt591 dt592.

  • Page 2

    Contents 1.Parts and functions............................................................................................. 1 2.Terminal descriptions .......................................................................................... 1 3.Specifications ...........................................

  • Page 3

    -1- 1.Parts and functions rainy cover camera lens night view led speaker nameplate call button microphone 90 mm 176 mm 23 mm 2.Terminal descriptions bus pl s1+ s2+ s- 1 2 on 1 2 on mic adjustment lock control jumper doorstation code dip main connect port 1 2 3 spk adjustment note: dt592 has two call...

  • Page 4

    -2- • lock control jumper: to select the lock type: see 5.2.1 , 5.2.2 • doorstation code dip: total 4 doorstations can be supported,see 6.1 • main connect port: to connect the bus line and the electronic locks. • bus: connect to the bus line, no polarity. • pl: external lock power input, connect to ...

  • Page 5

    -3- 4.2 mounting with rainy cover 160-165cm 1 2 1 2 3 4 4.3 placing name label move the plastic cover away to open the transparent name label cover, insert a name paper, then put the plastic cover back to the panel. Name label 1 2 on.

  • Page 6

    -4- 4.4 adjusting camera angle 5.1 basic connection use a screwdriver to loosen the screw and then adjust the angle of the camera ,then fix the screw. 5.System wiring and connections bus(im) bus(ds) pc6 ac~ doorbell button switch 1 2 3 on dips - + 1 2 on l1 l2 pl s1+ s2+ s-.

  • Page 7

    -5- 5.2 electric lock connection 5.2.1 door lock controlled with internal power connect one lock connect two locks note: 1. Electronic lock of power-on-to-unlock type should be used. 2. The door lock is limited to 12v, and holding current must be less than 250ma. 3. The door lock control is not time...

  • Page 8

    -6- lock bus pl s1 + s2 + s- take off the jumper power supply lock bus pl s1 + s2 + s- take off the jumper power supply lock connect one lock connect two locks 5.2.3 unlock parameter setting(set on monitor) note: 1.Must connect dt591/592 correctly before setting. 2.The parameter will be saved in dt5...

  • Page 9

    -7- 5.3 multi doorstations connection 1 2 on l1 l2 pl s1+ s2+ s- 1 2 on l1 l2 pl s1+ s2+ s- 1 2 on l1 l2 pl s1+ s2+ s- 1 2 on l1 l2 pl s1+ s2+ s- 1 2 on 1 2 on 1 2 on 1 2 on 1# camera id=00 id=10 id=01 id=11 2# camera 3# camera 4# camera 100~240vac dbc4a a b c d off on impedance switch bus(im) bus(d...

  • Page 10

    -8- 5.4.1 basic in-out wiring mode 5.4 multi monitors connection id=00 1 2 on code=14 code=15 note:here we take dt47m(the monitor) for example. Code=0 bus(im) bus(ds) pc6 ac~ 100~240vac.

  • Page 11

    -9- 5.4.2 with dbc4a wiring mode code=0 off on off on dbc4a a b c d dbc4a a b c d impedance switch impedance switch note:here we take dt47m(the monitor) for example. 100~240vac bus(im) bus(ds) pc6 ac~ code=2 code=1 code=3 code=12 code=14 code=13 code=15 id=00 1 2 on.

  • Page 12

    -10- 6.Setup 6.1 dip switches settings of doorstation total 2 bits on the dip switches can be configured.The switches can be modified either before or after installation. Bit state descriptions default setting, id = 0(00), set to the first door station. Id = 1(10), set to the second door station. Id...

  • Page 13

    -11- 1)power-on within 5 seconds; 2)press and hold "b" button for 3 seconds, it will enter the setting the state of prepare. Indicator buzzer beep+,beep (flash) press and hold "b" button for 3 seconds, it will enter the state of ringtone mode setting. Indicator buzzer beep+ (off) followed by pressin...

  • Page 14

    -12- 6.3 unlock time settings 1)power-on within 5 seconds; 2)press and hold "b" button for 3 seconds, it will enter the setting the state of prepare. Indicator buzzer beep+,beep (flash) press and hold "a" button for 3 seconds, it will enter the state of unlock time setting. Indicator buzzer beep+ (o...

  • Page 15

    -13- 7.Cables requirements the maximum distance of the wiring is limited in the dt system. Using different cables may also affect the maximum distance which the system can reach. When monitor quantity cable usage a b c twisted cable 2x0.75 mm 2 60 60 30 twisted cable 2x1 mm 2 80 80 40 when monitor q...

  • Page 16

    The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved..