VADDIO RoboSHOT 12 HDBT Installation Manual - page 9
Camera Settings
Use the DIP switches to set camera behaviors.
Note
When the camera is right side up, switches are in their default positions when they are up.
IR Frequency Selection:The IR Remote Commander can control up to three cameras in the same room
independently, if they are configured with different IR frequencies. Use switches 1 and 2 to select the
frequency to identify the camera as camera 1, 2, or 3; then use the Camera Select buttons at the top of the
remote to select the camera you want to control.
IR: Leave switch 3 in the default UP position if the IR remote will be used.
Image Flip: If mounting the camera upside-down, set switch 4 to the DOWN position: IMAGE FLIP ON.
Super Wide Mode (RoboSHOT 12 HDBT only): To use Super-wide mode, set switch 5 to the DOWN
position. This gives 12X zoom with a 73º horizontal angle of view. Normal mode provides 10X zoom with a
67.2º horizontal field of view (HFOV).
Baud Rate: Set the baud rate for RS-232 communication using switch 6. Most applications use 9600 bps
(switch 6 UP), which is recommended when using long cable runs. Use the 38,400 bps setting (switch 6
DOWN) for short control lines only.
Leave Switch 7 in the default UP position unless sRGB color output is needed.
Switch 8 is not currently used.
Pro Tip
Double-check switch settings before you mount the camera.
7
Installation Guide for RoboSHOT HDBT High-Performance PTZ Cameras