Manual is about: Solar Differential Controller

Summary of auroMATIC VRS 560

  • Page 1

    Vrs 560 operating and installation manual auromatic 560 solar differential controller gb.

  • Page 2

    Operating manual auromatic 560 2 contents general information . . . . . . . . . . . . . . . . . . . . . . . . . 3 special product features . . . . . . . . . . . . . . . . . . . . . 3 1 notes on the documentation . . . . . . . . . . . . 3 1.1 storage of the documents . . . . . . . . . . . . . . . . ....

  • Page 3

    3 operating manual auromatic 560 general information the solar controller auromatic 560 is a temperature- controlled differential controller set for solar hot water preparation with a demand driven reheating function for vaillant boilers. The control set is a fully-equipped system for controlling so...

  • Page 4

    4 operating manual auromatic 560 3.2 intended use the auromatic 560 solar controller is a state-of-the-art appliance which has been constructed in accordance with recognised safety regulations. Nevertheless, improper use can cause serious or fatal injury to the user or others, and the appliance or o...

  • Page 5

    5 operating manual auromatic 560 a temperature of at least 68 °c has been maintained for a period of 30 minutes. The heating engineer activates the anti-legionnaire’s disease protection in the installer level and specifies whether the heating process should take place at 3:30 p.M. Or at 4:00 a.M. (i...

  • Page 6

    6 operating manual auromatic 560 5.3 display overview 4 1 2 3 5 6 7 8 9 10 11 12 13 fig. 5.2 controls key 1 programming level 2 service/diagnostic level 3 reheating 4 timer programs 5 info level 6 solar yield (blinks if solar yield is available) 7 units 8 cursor 9 multifunction display 10 days of th...

  • Page 7

    7 operating manual auromatic 560 5.4.3 programming level you can access the level for programming the control- ler‘s operating times by pressing the “p” programming button. You can set timer programs here for reheating the solar cylinder and for the connected circulation pump (see sec. 6.3 and 6.4)....

  • Page 8

    8 operating manual auromatic 560 5.5 settings 5.5.1 calling up values for settings you can call up values for the settings successively by repeatedly pressing the info button. The information called up appears on the display for approx. Five seconds, then the display returns to the main operating le...

  • Page 9

    9 operating manual auromatic 560 5.5.3 setting the timer program for reheating you can create a timer program with up to three time windows for reheating the solar cylinder. The controller is equipped with a default program which can be customised to meet your individual needs. Time window weekday /...

  • Page 10

    10 operating manual auromatic 560 5.6 activating the special functions display required steps party function press the special function button once- the party symbol flashes for approx. Ten seconds in the display, then the function is activated. The function is deactivated automatically when the nex...

  • Page 11

    For the heating engineer installation manual auromatic 560 installation manual auromatic 560 1 contents 1 notes on the documentation . . . . . . . . . . . . 2 1.1 storage of the documents . . . . . . . . . . . . . . . . . . 2 1.2 symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 12

    2 installation manual auromatic 560 1 notes on the documentation the following information is intended to help you throughout the entire documentation. Further documents apply in combination with this oper- ating and installation manual. We accept no liability for any damage caused by non- observanc...

  • Page 13

    3 installation manual auromatic 560 4 installation 4.1 scope of delivery using table 4.1, verify the scope of delivery for the con- troller set. Item quantity components 1 1 auromatic 560 controller 2 1 vr 11 collector sensor 3 2 vr 10 standard sensor 4 1 c1/c2 cable table 4.1 scope of delivery 4.2 ...

  • Page 14

    4 installation manual auromatic 560 proe-system wiring c1/c2 c1 c2 kol1 2 1 sp1 2 1 sp2 2 1 sp3 2 1 ertrag 2 1 kol2 2 1 230 v~ pe n l kol1-p pe n l leg/byp pe n l lp/uv1 pe n l ep 2 1 kol2-p/zp pe n l 3 fig. 4.4 fold-up the control panel • fold the control panel towards the top. • wire the controlle...

  • Page 15

    5 installation manual auromatic 560 5.1 wiring according to hydraulic plan to simplify installation, three hydraulic plans are stored in the controller. The relevant plan must be selected according to the system configuration used. Each of the hydraulic plans show a possible system config- uration i...

  • Page 16

    6 installation manual auromatic 560 5.2 hydraulic plan 1 kol 1 kol1-p gain sp1 sp2 legp zp kw i ii iii c1 c2 c1 c2 c1 c2 230 v 230 v ep hz -k hz -k hz -k s 2 1 fig. 5.1 hydraulic plan 1 with system configuration: one collec- tor array, one solar cylinder, connection option for vari- ous heaters for ...

  • Page 17

    7 installation manual auromatic 560 230v netz f 1 t4 kol 1-p kol 2-p / zp leg/byp ep lp/uv 1 vrs 560 c1 c2 kol 1 sp 1 sp 2 sp 3 gain kol 2 5 v / 2 4 v 23 0 v ~ vu / vk fig. 5.2 wiring diagram for hydraulic plan 1 electrical installation 5.

  • Page 18

    8 installation manual auromatic 560 hydraulic plan 1: connection of a second cylinder or swimming pool kol1-p kol 1 hg sp2 sp1 s 2 1 lp / uv 1 kw legp sr sp3 sp3 230 v c1 c2 zp ep gain a fig. 5.3 hydraulic plan 1: connection of a second cylinder or swimming pool designation in hydraulic plan/ wiring...

  • Page 19

    9 installation manual auromatic 560 230v netz f 1 t4 kol 1-p kol 2-p / zp leg/byp ep lp/uv 1 vrs 560 c1 c2 kol 1 sp 1 sp 2 sp 3 gain kol 2 5 v / 2 4 v 23 0 v ~ vu / vk fig. 5.4 wiring diagram for hydraulic plan 1: connection of a second cylinder or swimming pool electrical installation 5.

  • Page 20

    10 installation manual auromatic 560 5.3 hydraulic plan 2 kol 1 kol 2 kol1-p kol2-p ep sp1 sp2 le gp s c1 c2 230v 230v hz -k c1 c2 c1 c2 kw i ii 2 1 hz -k hz -k gain fig. 5.5 hydraulic plan 2 with system configuration: two col- lector arrays, one solar cylinder, connection option for various heaters...

  • Page 21

    11 installation manual auromatic 560 230v netz f 1 t4 kol 1-p kol 2-p / zp leg/byp ep lp/uv 1 vrs 560 c1 c2 kol 1 sp 1 sp 2 sp 3 gain kol 2 5 v / 2 4 v 23 0 v ~ vu / vk fig. 5.6 wiring diagram for hydraulic plan 2 electrical installation 5.

  • Page 22

    12 installation manual auromatic 560 hydraulic plan 2: connection of a second cylinder or swimming pool legp hg sp3 2 2 1 s kol 2 kol 1 kol2-p kol1-p sp1 sp2 lp / uv 1 sr c1 c2 230 v ep sp3 a kw gain fig. 5.7 hydraulic plan 2: connection of a second cylinder or swimming pool designation in hydraulic...

  • Page 23

    13 installation manual auromatic 560 230v netz f 1 t4 kol 1-p kol 2-p / zp leg/byp ep lp/uv 1 vrs 560 c1 c2 kol 1 sp 1 sp 2 sp 3 gain kol 2 5 v / 2 4 v 2 3 0 v~ vu / vk fig. 5.8 wiring diagram for hydraulic plan 2: connection of a second cylinder or swimming pool electrical installation 5.

  • Page 24

    14 installation manual auromatic 560 5.4 hydraulic plan 3 kol 1 230 v kol1-p gain sp1 sp2 ep s 1 2 kw legp kol2p kol2 hz -k hz -k hz -k c1 c2 c1 c2 c1 c2 230 v i ii iii fig. 5.9 hydraulic plan 3 with system configuration: one col- lector array, one solid-fuel boiler, one solar cylinder, connection o...

  • Page 25

    15 installation manual auromatic 560 230v netz f 1 t4 kol 1-p kol 2-p / zp leg/byp ep lp/uv 1 vrs 560 c1 c2 kol 1 sp 1 sp 2 sp 3 gain kol 2 5 v / 2 4 v 23 0 v ~ vu / vk fig. 5.10 wiring diagram for hydraulic plan 3 electrical installation 5.

  • Page 26

    16 installation manual auromatic 560 hydraulic plan 3: connection of a second cylinder or swimming pool kol1-p kol 1 sp2 sp1 s 2 1 lp / uv 1 kw legp sr sp3 sp3 230 v c1 c2 ep gain a c1 c2 c1 c2 hz -k hz -k hz -k 230 v kol2 kol2-p i ii iii fig. 5.11 hydraulic plan 3: connection of a second cylinder o...

  • Page 27

    17 installation manual auromatic 560 230v netz f 1 t4 kol 1-p kol 2-p / zp leg/byp ep lp/uv 1 vrs 560 c1 c2 kol 1 sp 1 sp 2 sp 3 gain kol 2 5 v / 2 4 v 23 0 v ~ vu / vk fig. 5.12 wiring diagram for hydraulic plan 3: connection of a second cylinder or swimming pool electrical installation 5.

  • Page 28

    18 installation manual auromatic 560 5.5 special plan: heater with “hot water capable” heating controller 230 v vrc-mf/ vrc-ubw spf-e hz -k kw zp legp sp1 sp2 gain kol1-p kol 1 fig. 5.13 connecting older boilers with “hot water capable” heating controllers, e.G., vrc-mf designation in hydraulic plan...

  • Page 29

    19 installation manual auromatic 560 ex t. St . 1. S t. 2. S t. Gw ak wm ex t. M uv / lp hp 2 3 0v~ 230v netz f 1 t4 kol 1-p kol 2-p / zp leg/byp ep lp/uv 1 vrs 560 c1 c2 kol 1 sp 1 sp 2 sp 3 gain kol 2 5 v / 2 4 v 2 3 0 v~ vk / vrc 3 kf b u s / fb g spf dcf / af f1 f2 fig. 5.14 wiring diagram for s...

  • Page 30

    20 installation manual auromatic 560 6 start-up 6.1 setting the system parameters certain system parameters have to be set in order to optimise the system for the respective conditions. These parameters are all together on one operating level and should only be set by the heating engineer. You can a...

  • Page 31

    21 installation manual auromatic 560 display turn the dial to adjust setting range factory setting setting the max. Temperature for cylinder 2 20 - 80 °c 60 °c setting the activation difference for cylinder 2 (the activation difference should always be 2 k greater than the deactivation differ- ence)...

  • Page 32

    22 installation manual auromatic 560 6.2 resetting system parameters to the default settings you can reset the system parameters and the timer pro- grams to the default settings by pressing the program- ming button “p” for ten seconds. Then the display flash- es three times and all of the parameters...

  • Page 33

    23 installation manual auromatic 560 display actuators/sensor values test procedure cylinder temperature display for cylinder sensor 2 temperature display for cylinder sensor 3 temperature display for collector sensor 1 temperature display for collector sensor 2 temperature display for return flow (...

  • Page 34

    24 installation manual auromatic 560 10 technical data features units auromatic 560 operating voltage controller current consumption contact load of output relays (max.) maximum total current v ac/hz w a a 230/50 max. 10 2 4 shortest switching interval power reserve maximum ambient temperature senso...

  • Page 36

    00 2 000 84 2 7_00 gb 08 2 0 05.