Vaillant auroMATIC VRS 560 Operating And Installation Manual

Other manuals for auroMATIC VRS 560: Operating And Installation Manual
Manual is about: Solar Differential Controller

Summary of auroMATIC VRS 560

  • Page 1

    For the operator/expert technician operating and installation manual auromatic 560 solar differential controller vrs 560 gb.

  • Page 2

    For the operator/expert technician vrs 560 solar differential controller operating manual auromatic 560 contents general information ................................................... 3 special product features .......................................... 3 1 notes on the documentation .................

  • Page 3

    3 operating manual – auromatic 560 0020008427_01 general information the auromatic 560 solar controller is a temperature- controlled differential controller set for solar hot water generation with a demand-oriented reheating function for vaillant boilers. The control set is a fully-equipped system f...

  • Page 4

    Operating manual – auromatic 560 0020008427_01 4 3 information on installation and operation 3.1 vaillant warranty we only grant a vaillant manufacturers warranty if a suitably qualified engineer has installed the system in accordance with vaillant instructions. The system owner will be granted a wa...

  • Page 5

    5 operating manual – auromatic 560 0020008427_01 4 functions 4.1 solar yield the solar controller works on the principle of differen- tial temperature control system. The controller always switches on the collector pump when the difference in temperature (collector temperature - cylinder tempera- tu...

  • Page 6

    Operating manual – auromatic 560 0020008427_01 6 4.9 special functions please refer to sec. 5.6 for information on how to acti- vate the following special functions. 4.9.1 advance when the advance is activated, the reheating function is enabled. This means that the set target value for the cylinder ...

  • Page 7

    7 operating manual – auromatic 560 0020008427_01 5 operation 5.1 operator guidance the controller has a display which consists of symbols, and is designed according to the vaillant "turn and click" operating concept. You can call up and set values by turning the dial. You can also click the dial in ...

  • Page 8

    Operating manual – auromatic 560 0020008427_01 8 5.4 display types 5.4.1 display, main operating level the main operating level appears when the appliance is switched on. Please refer to sec. 5.5.2 for information on how to set and change the values. 1 2 4 6 3 5 fig. 5.3 display, main operating leve...

  • Page 9

    9 operating manual – auromatic 560 0020008427_01 5.4.5 display, service/diagnostics level the actuators and sensors should be checked by the technician expert. You can access the service/diagnostics level by simulta- neously pressing the programming button "p" and the dial for roughly 3 seconds. All...

  • Page 10

    Operating manual – auromatic 560 0020008427_01 10 operating modes: reheating function with timer program reheating function in constant standby mode no reheating no actuation of solar pump(s), no reheating reheating function in automatic mode – the corresponding symbol for the time window status is ...

  • Page 11

    11 operating manual – auromatic 560 0020008427_01 5.5.4 setting the timer program, circulation pump you can create a customised timer program for a con- nected circulation pump (only possible for hydraulic plan 1), just as you can for the reheating function. The controller is equipped with a default...

  • Page 13

    For the operator/expert technician vrs 560 solar differential controller 1 notes on the documentation ......................... 2 1.1 storage of documents ...........................................2 1.2 symbols used ...........................................................2 1.3 validity of manual...

  • Page 14

    Installation instructions – auromatic 560 0020008427_01 2 1 notes on the documentation the following information is intended to help you throughout the entire documentation. Further documents apply in combination with this oper- ating and installation manual. We accept no liability for any damage ca...

  • Page 15

    3 installation instructions – auromatic 560 0020008427_01 3 safety instructions and regulations 3.1 safety instructions the controller must be installed by a qualified engineer, who is responsible for adhering to the existing stand- ards and regulations. We accept no liability for any dam- age cause...

  • Page 16

    Installation instructions – auromatic 560 0020008427_01 4 4.4 installing the controller housing the controller is designed to be mounted on a wall and is equipped with system proe terminal strips. These ter- minals must be used for all connections made at the in- stallation site. Fig. 4.2 opening th...

  • Page 17

    5 installation instructions – auromatic 560 0020008427_01 a caution! An optional electrical heating rod (ep) must be installed with an additional relay or contactor with a circuit-breaking capacity of at least 16 a. Never operate an electrical heating rod in connection with the auromatic 560 without...

  • Page 18

    Installation instructions – auromatic 560 0020008427_01 6 5.2 hydraulic plan 1 vrs 560 sp1 (vr 10) 230 v ~ zp sp2 (vr 10) ertrag (vr 10) kol1 (vr 11) kol1-p leg/byp ep 1 s 230 v ~ c1/c2 le g /b y p i ii iii c1/c2 c1/c2 c1/c2 230 v hz -k hz -k hz -k fig. 5.1 hydraulic plan 1 with system configuration...

  • Page 19

    7 installation instructions – auromatic 560 0020008427_01 230v netz f 1 t4 kol1-p kol2-p / zp leg/byp ep lp/uv 1 vrs 560 c1/c2 kol1 sp1 sp2 sp3 ertrag kol2 5 v / 2 4 v 2 30 v~ vc / vk fig. 5.2 connection diagram for hydraulic plan 1 h note leg/byp can be used as a legionella protection pump or an el...

  • Page 20

    Installation instructions – auromatic 560 0020008427_01 8 hydraulic plan 1: connection of a second cylinder or swimming pool 1 sp1 (vr 10) leg/byp vrs 560 230 v ~ zp sp2 (vr 10) ertrag (vr 10) kol1 (vr 11) kol1-p sp3 (vr 10) 400 v lp/uv1 2 hg 3 ep s c1/c2 le g /b y p sp3 a fig. 5.3 hydraulic plan 1:...

  • Page 21

    9 installation instructions – auromatic 560 0020008427_01 designation in hydraulic plan/ wiring diagram components c1/c2 connections for controlling the heater used for reheating the cylinder hg boiler kw cold water zp circulation pump ep electrical heating rod (optional) sr swimming pool controller...

  • Page 22

    Installation instructions – auromatic 560 0020008427_01 10 hydraulic plan 1: integration into monovalent sys- tems the controller can also be used in conjunction with units that heat water according to the principle of instantane- ous heating. Integrate the controller according to the following hydr...

  • Page 23

    11 installation instructions – auromatic 560 0020008427_01 230v netz f 1 t4 kol1-p kol2-p / zp leg/byp ep lp/uv 1 vrs 560 c1/c2 kol1 sp1 sp2 sp3 ertrag kol2 5 v / 2 4 v 2 30 v~ fig. 5.6 connection diagram for hydraulic plan 1: integration of auromatic 560 in monovalent systems h danger! Danger of ov...

  • Page 24

    Installation instructions – auromatic 560 0020008427_01 12 5.3 hydraulic plan 2 vrs 560 sp1 (vr 10) zp sp2 (vr 10) ertrag (vr 10) kol1 (vr 11) kol1-p leg/byp ep 1 s 230 v ~ kol2 (vr 11) kol2-p leg/byp c1/c2 i ii iii c1/c2 c1/c2 c1/c2 230 v hz -k hz -k hz -k fig. 5.7 hydraulic plan 2 with system conf...

  • Page 25

    13 installation instructions – auromatic 560 0020008427_01 230v netz f 1 t4 kol1-p kol2-p / zp leg/byp ep lp/uv 1 vrs 560 c1/c2 kol1 sp1 sp2 sp3 ertrag kol2 5 v / 2 4 v 23 0 v ~ vc / vk fig. 5.8 connection diagram for hydraulic plan 2 h note leg/byp can be used as a legionella protection pump or an ...

  • Page 26

    Installation instructions – auromatic 560 0020008427_01 14 hydraulic plan 2: connection of a second cylinder or swimming pool 1 c1/c2 sp1 (vr 10) leg/byp vrs 560 230 v ~ zp sp2 (vr 10) ertrag (vr 10) kol1 (vr 11) kol1-p sp3 (vr 10) 400 v lp/uv 1 2 hg 3 ep s kol2 (vr 11) le g /b y p kol2-p sp 3 a fig...

  • Page 27

    15 installation instructions – auromatic 560 0020008427_01 designation in hydraulic plan/ wiring diagram components c1/c2 connections for controlling the heater used for reheating the cylinder hg boiler ep electrical heating rod (optional) sr swimming pool controller (provided by custom- er) lp/uv 1...

  • Page 28

    Installation instructions – auromatic 560 0020008427_01 16 5.4 hydraulic plan 3 vrs 560 sp1 (vr 10) 230 v ~ zp sp2 (vr 10) ertrag (vr 10) kol1 (vr 11) kol1-p leg/byp ep 1 s 230 v ~ c1/c2 i ii iii c1/c2 c1/c2 c1/c2 230 v hz -k hz -k hz -k k ol2 -p kol2 fig. 5.11 hydraulic plan 3 with system configura...

  • Page 29

    17 installation instructions – auromatic 560 0020008427_01 230v netz f 1 t4 kol1-p kol2-p / zp leg/byp ep lp/uv 1 vrs 560 c1/c2 kol1 sp1 sp2 sp3 ertrag kol2 5 v / 2 4 v 23 0 v ~ vc / vk fig. 5.12 wiring diagram for hydraulic plan 3 h note leg/byp can be used as a legionella protection pump or an ele...

  • Page 30

    Installation instructions – auromatic 560 0020008427_01 18 hydraulic plan 3: connection of a second cylinder or swimming pool 1 sp1 (vr 10) leg/byp vrs 560 230 v ~ zp sp2 (vr 10) ertrag (vr 10) kol1 (vr 11) kol1-p sp3 (vr 10) 230 v ~ lp/uv 1 2 3 ep s sp3 a kol2-p kol2 fig. 5.13 hydraulic plan 3: con...

  • Page 31

    19 installation instructions – auromatic 560 0020008427_01 designation in hydraulic plan/ wiring diagram components c1/c2 connections for controlling the heater used for reheating the cylinder hz-k heating circuit kw cold water ep electrical heating rod (optional) sr swimming pool controller (provid...

  • Page 32

    Installation instructions – auromatic 560 0020008427_01 20 6 start-up 6.1 setting system parameters certain system parameters have to be set in order to optimise the system for the respective conditions. These parameters are all together on one operating level and should only be set by the heating e...

  • Page 33

    21 installation instructions – auromatic 560 0020008427_01 display turn the dial to adjust setting range factory setting setting the activation difference for cylinder 1 (the activation difference should always be 2 k greater than the deactivation difference) 2 – 25 k 7 k setting the deactivation di...

  • Page 34

    Installation instructions – auromatic 560 0020008427_01 22 display turn the dial to adjust setting range factory setting prot solar circuit protection function off, 110 °c – 150 °c 130 °c kolt: collector type 1 = flat collector 2 = tube collector 1, 2 1 leg anti-legionella function off, 1, 2, 3, 4, ...

  • Page 35

    23 installation instructions – auromatic 560 0020008427_01 6.2 resetting the system parameters to the de- fault setting you can restore the default settings for system parame- ters and timer programs by pressing the programming button "p" for roughly ten seconds. Then the display flashes three times...

  • Page 36

    Installation instructions – auromatic 560 0020008427_01 24 display actuators/sensor values test procedure cylinder temperature display for cylinder sensor 1 cylinder temperature display for cylinder sensor 2 temperature display for cylinder sensor 3 temperature display for collector sensor 1 tempera...

  • Page 37

    25 installation instructions – auromatic 560 0020008427_01 8 emergency mode when the auromatic 560 detects an error, its basic dis- play always shows the error. If either the solar yield or reheating function is possible, the controller carries out this function in spite of the error. 9 technical da...

  • Page 38

    Installation instructions – auromatic 560 0020008427_01 26 10 sensor characteristics vr 10 standard sensor, type ntc 2.7 k sensor values resistance value 0 °c 9191 ohm 5 °c 7064 ohm 10 °c 5214 ohm 20 °c 3384 ohm 25 °c 2692 ohm 30 °c 2158 ohm 40 °c 1416 ohm 50 °c 954 ohm 60 °c 658 ohm 70 °c 463 ohm 8...

  • Page 40

    0020008427_01 gb 042008.