Vaillant geoTHERM exclusive Operating Manual

Other manuals for geoTHERM exclusive: Installation Instructions Manual
Manual is about: Heat pump with integrated domestic hot water cylinder and additional cooling function

Summary of geoTHERM exclusive

  • Page 1

    For the owner operating manual geotherm exclusive heat pump with integrated domestic hot water cylinder and additional cooling function vws gb.

  • Page 2

    Operating manual geotherm exclusive vws 0020071929_00 2 contents contents general information ..................................................... 3 data badge .............................................................................. 3 1 notes on this manual ......................................

  • Page 3

    3 operating manual geotherm exclusive vws 0020071929_00 1 notes on this manual the following information is intended to help you throughout the entire documentation. Further docu- ments apply in combination with this operating manual. We accept no liability for any damage caused by fail- ure to obse...

  • Page 4

    Operating manual geotherm exclusive vws 0020071929_00 4 1.3 symbols used the following hazard classification symbols are used for information, activities and energy saving tips in this op- erating manual. D danger! Immediate risk of serious injury or death h danger! Danger of burning and scalding! A...

  • Page 5

    5 operating manual geotherm exclusive vws 0020071929_00 2.2 prohibition on alterations d danger!Inappropriate alterations can cause injuries! Under no circumstances should you at- tempt to make changes or alterations to the heat pump or other parts of the heating and hot water system yourself. The p...

  • Page 6

    Operating manual geotherm exclusive vws 0020071929_00 6 d danger! Risk to life as a consequence of improper use of the installation. There is a risk of death or serious injury to the user or third parties or of damage to the device and other property in the event of improper use or use for which it ...

  • Page 7

    7 operating manual geotherm exclusive vws 0020071929_00 fig. 3.1 filling level of the brine expansion tank it is normal for the filling level of the brine to fall a little in the first month after the start-up of the system. The filling level can also vary depending on the temperature of the heat so...

  • Page 8

    Operating manual geotherm exclusive vws 0020071929_00 8 — for floor heating use heating curves of ator heating, we recommend that they are laid out to manage with a maximum flow temperature of 50 °c at the lowest outside temperature; this corresponds to heating curves of — an appropriate setting of ...

  • Page 9

    9 operating manual geotherm exclusive vws 0020071929_00 4 equipment and functional description 4.1 principle of operation heat pump systems consist of separate circuits in which liquids or gases transport the heat from the heat source to the heating system. As these circuits operate with differing m...

  • Page 10

    Operating manual geotherm exclusive vws 0020071929_00 10 these different temperatures are produced in the cool- ant circuit by means of a compressor (2) and an expan- sion valve (4), which are situated between the evapora- tor and the condenser. The coolant flows in vapour form from the evaporator i...

  • Page 11

    11 operating manual geotherm exclusive vws 0020071929_00 freezing protection function the outlet temperature of the heat source is constantly measured. If the heat source outlet temperature falls below a specific value, the compressor temporarily shuts off with the error message 20 or 21. If these e...

  • Page 12

    Operating manual geotherm exclusive vws 0020071929_00 12 4 3 1 2 6 5 9 8 7 fig. 4.4 rear view key to fig. 4.4 1 hot water connection, domestic hot water cylinder 2 cold water connection, domestic hot water cylinder 3 heat source to the heat pump 4 heat source from the heat pump 5 heating return 6 he...

  • Page 13

    13 operating manual geotherm exclusive vws 0020071929_00 5 operation 5.1 familiarising yourself with and operating the controller basic data date day of week time set day 2 1 3 4 5 6 fig. 5.1 sample illustration no. 3fig. 7.1 overview of operation key 1 menu name 2 cursor indicating the selected par...

  • Page 14

    Operating manual geotherm exclusive vws 0020071929_00 14 5.2 setting menus and parameters setting to date modified setting holiday programming 6 for cpl. System period of time 1 >06.01.08 08.01.08 2 14.01.08 30.01.08 room temp. Setpoint 12°c >set start day select menu: • turn the dial: select menu e...

  • Page 15

    15 operating manual geotherm exclusive vws 0020071929_00 5.3.2 energy balance control energy balance control applies only to hydraulic sys- tems without buffer cylinders (e.G. Hydraulic plan 6). For economical and fault-free operation of a heat pump, it is important to regiment the starting of the c...

  • Page 16

    Operating manual geotherm exclusive vws 0020071929_00 16 5.4 flow diagram hk2 parameter 2 betriebsart heizen >auto 15 ºc night set back temp. 20 ºc raumsolltemp. Hk2 parameters 2 heating mode >auto 15 ºc night set back temp. 20 ºc set value day mo 21.04.08 flow temp. Ch 16:49 system pressure 1,2bar ...

  • Page 17

    17 operating manual geotherm exclusive vws 0020071929_00 5.5 user level displays the individual displays on the operating panel are de- scribed and explained below. Display shown description graphics display (top-level display) you can read off the instantaneous state of the system from this dis- pl...

  • Page 18

    Operating manual geotherm exclusive vws 0020071929_00 18 display shown description energy input display shows the energy extracted from the environment for each of the 12 months of the current year (black bar). White-filled bars represent the future months of the year; the height of the bar correspo...

  • Page 19

    19 operating manual geotherm exclusive vws 0020071929_00 display shown description factory setting hk2 2 parameters operating mode heating >auto set value day 22°c night set back temp. 15°c >select operating mode the room set target temperature is the tempera- ture to which the heating should be reg...

  • Page 20

    Operating manual geotherm exclusive vws 0020071929_00 20 display shown description factory setting dhw loading 4 parameters operating mode ww auto auto max. Dhw temp. 60°c 60°c min. Dhw temp. 44°c 44°c cylinder temp. Real 51°c 51°c >select set target temperature for connected domestic hot water cyli...

  • Page 21

    21 operating manual geotherm exclusive vws 0020071929_00 display shown description factory setting dhw loading 5 time programme >mon 1 06:00 22:00 2 : : 3 : : >select weekday/block you can set the times at which the domestic hot water cylinder is heated in the "ww timer pro- gramme" menu. Up to thre...

  • Page 22

    Operating manual geotherm exclusive vws 0020071929_00 22 display shown description factory setting holiday programming 6 for cpl. System period of time 1 >06.01.08 08.01.08 2 14.01.08 30.01.08 room temp. Setpoint 12°c >set start day for the controller and its connected system compo- nents it is poss...

  • Page 23

    23 operating manual geotherm exclusive vws 0020071929_00 5.6 special functions special functions can be selected only from the basic display. To do so press the left-hand dial . To change the parameter, you must turn the dial. The following special functions can be selected: • energy saving function...

  • Page 24

    Operating manual geotherm exclusive vws 0020071929_00 24 display shown description we 16.02.08 9:35 cooling function active for > 3 days cooling operation: cooling duration: off/1 to 99 days. If the cooling operation is active, – the symbol of an ice crystal appears in the graphic display. Table 5.2...

  • Page 25

    25 operating manual geotherm exclusive vws 0020071929_00 5.7 starting up the heat pump the start-up of your heat pump was carried out after in- stallation by your expert technician company. A repeated start-up will not even be necessary in the event that your heat pump disconnects from the mains une...

  • Page 26

    Operating manual geotherm exclusive vws 0020071929_00 26 5.10.2 activating emergency mode depending on the type of malfunction the expert techni- cian can set the heat pump to continue operation in emergency mode (via an integrated electric auxiliary heating) until the cause of the error is remedied...

  • Page 27

    27 operating manual geotherm exclusive vws 0020071929_00 5.10.6 fault-induced shutdown errors could occur which result in the shutdown of the heat pump. Fault code error text/description emergency mode 32 error heat source sensor t8 short-circuit in the sensor possible 33 error heat circuit pressure...

  • Page 28

    Operating manual geotherm exclusive vws 0020071929_00 28 6 warranty and customer service 6.1 vaillant warranty vaillant provide a full parts and labour warranty for this appliance. The appliance must be installed by a suitably competent person in accordance with the gas safety (installation and use)...

  • Page 29

    29 operating manual geotherm exclusive vws 0020071929_00 7 appendix 7.1 technical data a caution! R 407 c is a chlorine-free coolant which does not affect the ozone layer. Never- theless, servicing work on the cooling circuit should only be carried out by au- thorised specialists. Description unit v...

  • Page 30

    Operating manual geotherm exclusive vws 0020071929_00 30 description unit vws 63/2 230 v vws 83/2 230 v vws 103/2 230 v integrated domestic hot water cylinder - contents - max. Operating pressure - max. Temperature with heat pump - max. Temp. With heat pump and auxiliary heating l mpa (bar) °c °c 17...

  • Page 31

    31 operating manual geotherm exclusive vws 0020071929_00 7.2 identification plate an identification plate is attached to the baseplate on the inside of the geotherm exclusive heat pump. The type designation is located at the top of the front clad- ding (see fig. 4.3, item 2). R407 c cop b0/w35 4,2 c...

  • Page 32

    0020071929_00 gb 102008.