Vaillant VRC 700 Operating Instructions Manual - page 14
Operating and display functions 5
13
5.2.13.1 Setting the tariff for the auxiliary boiler
Menu
→
Basic settings
→
Costs
→
Tariff for auxiliary
boiler
–
The factor/value that is set requires the hybrid manager
to calculate costs correctly.
To set the correct factor/value, you must ask your energy
provider what your gas and electricity tariff is.
5.2.13.2 Setting the low-tariff electricity rate
Menu
→
Basic settings
→
Costs
→
Low-tariff electricity
rate
–
The factor/value that is set requires the hybrid manager
to calculate costs correctly.
To correctly set the
Low-tariff electricity rate
, you must ask
your energy supplier what your electricity rate is.
5.2.13.3 Setting the high-tariff electricity rate
Menu
→
Basic settings
→
Costs
→
High-tariff electricity
rate
–
The factor/value that is set requires the hybrid manager
to calculate costs correctly.
To correctly set the
High-tariff electricity rate
, you must
ask your energy supplier what your electricity rate is.
5.2.14 Set offset room temperature
Menu
→
Basic settings
→
Offset
→
Room temperature
–
The controller can display the current room temperature if
it is installed in a living room.
A thermometer is integrated in the controller for measuring
the room temperature. You can use the offset to correct the
measured temperature value.
5.2.15 Set offset outside temperature
Menu
→
Basic settings
→
Offset
→
Outside temperature
–
The thermometer in the controller's outside temperature
sensor measures the outside temperature. You can use
the offset to correct the measured temperature value.
5.2.16 Changing a zone name
Menu
→
Basic settings
→
Enter zone name
–
You can now modify the factory-specified zone names as
you wish. The name is limited to 10 characters.
5.2.17 Activating heat recovery
Menu
→
Basic settings
→
Heat recovery
–
The
Heat recovery
function has been set to
Auto
.
This means that an internal control system checks
whether heat recovery makes sense, or whether the
outdoor air can be guided directly into the living room.
For more information, see the operating instructions for
recoVAIR.../4
and later models.
If you have selected
Activate
, heat recovery will be used
constantly.
5.2.18 Setting the room air humidity
Menu
→
Basic settings
→
Room air humidity
–
If the room air humidity exceeds the value set, a connec-
ted dehumidifier is activated. As soon as the value drops
below the value that is set, the dehumidifier switches off
again.
5.2.19 Resetting to factory setting
You can reset the settings for the
Time programmes
or for
Everything
to the factory setting.
Menu
→
Basic settings
→
Default setting
→
Time pro-
grammes
–
With
Time programmes
, you reset all the settings you
have made in the
Time programmes
function to the
default setting. All other settings that include times, such
as
Date/Time
, are not affected.
While the controller is resetting the time programme settings
to the factory settings,
In progress
is shown on the display.
The basic display is then displayed.
Caution.
Risk of a malfunction.
The
Everything
function restores all settings
to the factory settings, including those set by
the competent person. It may be the case
that it is no longer possible to operate the
heating installation after this.
▶
Arrange for the competent person to reset
all settings to factory settings.
Menu
→
Basic settings
→
Default setting
→
Everything
–
While the controller is resetting the settings to the factory
settings,
In progress
is shown on the display. Then the
installation assistant appears in the display, which only
the competent person may operate.
5.2.20 Installer level
The Installer level is reserved for the competent person and
is therefore protected by an access code. At this level, the
competent person can implement the required settings.
5.3
Operating modes
The operating modes can be activated directly from any op-
erating mode using the right-hand selection button
Operat-
ing mode
. If the heating installation is equipped with more
than one zone, the activated operating mode only applies for
the zone that was preset by the competent person.
If more than one zone is activated, you can set a separate
operating mode for each zone using the left-hand selection
button
Menu
→
Basic setting
.
The path details given at the start of each operating mode
description indicate how you reach this operating mode in
the menu structure.