4
primary harness (H1), 12-pin connector
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
H1/1 RED (+)12V constant power input
Before connecting this wire, remove the supplied fuse. Connect to the battery positive terminal or
the constant 12V supply to the ignition switch.
NOTE: Always use a fuse within 12 inches of the point you obtain (+)12V. Do not use the fuse in
the harness for this purpose. This fuse protects the module itself.
H1/2 BLUE (-) 200 mA Second Unlock Output
The H1/2 BLUE output is used for progressive unlock. A progressive unlock system unlocks the
driver's door when the unlock (disarm) button is pressed and unlocks the passenger doors if the
unlock (disarm) button is pressed again within 15 seconds after unlocking the driver's door. The
BLUE wire outputs a low current (-) pulse on the second press of the unlock button of the trans-
mitter. This negative unlock output is used to unlock the passenger doors.
RED/WHITE
(-) OUTPUT OF CHANNEL 2
BROWN/BLACK
UNLOCK #87A NORMALLY CLOSED
ORANGE
(-) 500 mA GROUND-WHEN-ARMED OUTPUT
YELLOW
(+) SWITCHED IGNITION INPUT (ACCESSORY)
WHITE/BLUE
(-) 200 mA CHANNEL 3 VALIDITY OUTPUT
LT. GREEN/BLACK
FACTORY ALARM DISARM
BROWN
(-) HORN HONK OUTPUT
BLACK
(-) CHASSIS GROUND INPUT
WHITE
(+/-) PARKING LIGHT FLASH OUTPUT
VIOLET
UNLOCK #87 NORMALLY OPEN (INPUT)
BLUE/BLACK
UNLOCK #30 COMMON (OUTPUT)
VIOLET/BLACK
LOCK #87 NORMALLY OPEN (INPUT)
WHITE/BLACK
LOCK #87 NORMALLY CLOSED
GREEN/BLACK
LOCK #30 COMMON OUTPUT
BLACK/WHITE
OUTPUT OF DOMELIGHT SUPERVISION RELAY #30
BLACK/WHITE-1
INPUT OF DOMELIGHT SUPERVISION RELAY #87
BLUE
(-) 200 mA SECOND UNLOCK OUTPUT
RED
(+) 12V CONSTANT POWER INPUT
H1/1
H1/2
H1/3
H1/4
H1/5
H1/6
H1/7
H1/8
H1/9
H1/10
H1/11
H1/12
H1/13
H1/14
H1/15
H1/16
H1/17
H1/18