Valor 1600IN Installation & Owner's Manual

Other manuals for 1600IN: Installation & Owner's Manual
Manual is about: L1 SERIES DV ZC Two-Sided Gas Fireplace

Summary of 1600IN

  • Page 1

    L1 s eries dv zc two-sided gas fireplace 1600in (ng) & 1600ip (lpg) installation & owner’s manual 4003537-05 ©2014, miles industries ltd. This manual contains instructions to install the engine only. A front or trim kit is required to install the engine. A barrier screen is provided with the front o...

  • Page 2

    2 table of contents safety precautions ................................................. 3 safety and your fireplace ...................................... 4 owner’s information ............................................... 5 operating your fireplace for the first time ............... 5 cleaning y...

  • Page 3: Safety Precautions

    3 safety precautions ! Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be ...

  • Page 4: Safety And Your Fireplace

    4 safety and your fireplace please follow these important child safety precautions and recommendations, • parts of your valor fireplace become extremely hot while in operation. • the glass viewing window temperature can exceed 500 f at full capacity. Momentary contact with a hot glass surface can ca...

  • Page 5: Do Not Put

    5 operating your fireplace for the first time when operating your new fi replace for the fi rst time, some vapors may be released due to the burning of curing compounds used in the manufacture of the appliance. They may cause a slight odor and could cause the fl ames to be the full height of the fi ...

  • Page 6

    6 warning do not touch the glass while it is hot! Let the fi replace cool fi rst before cleaning it. ! Spring loaded window levers cleaning your fireplace important - glass cleaning - mineral deposits one of the by-products of the combustion process in a gas appliance is a mineral which can show up ...

  • Page 7

    7 warning choking hazard! Ensure that the fi replace area is clear of fi re glass or vermiculite particles as these could be ingested by small children. Vacuum thoroughly around the fi replace area after cleaning. Pilot flame thermocouple probe must be in flame warning for safety purpose, ensure the...

  • Page 8

    8 warning do not attempt to change the batter- ies while the fireplace is still hot! Let the fi replace cool fi rst before touching it. Caution do not use a screwdriver or other metallic object to remove the batteries from the battery box or the handset! This could cause a short circuit. Battery box...

  • Page 9

    9 warning do not attempt to touch the data plate while the fireplace is still hot! Let the fi replace cool fi rst before touching it. Data plate window the rating plate is located on the bottom of the appli- ance behind the front panel on the valve access side. Thermostatic remote control wall switc...

  • Page 10

    10 gas valve the battery box and the gas valve are located on the bottom of the appliance behind the front panel on the valve access side. Battery box in carrier receiver window gas valve how to ensure your fireplace cannot be turned on inadvertently you can use one of the two following methods to e...

  • Page 11

    11 remote control operation note: before using the remote control system for the fi rst time, the receiver and the handset must be synchronized. See the section remote control initial set-up on page 48 of this manual. Important: before you begin, please note that on this system, the settings of time...

  • Page 12

    12 remote control operation setting the time setting ºc/24-hour or ºf/12-hour clock modes of operation note: manual mode can also be reached by pressing either the (large fl ame) or the (small fl ame) buttons. • press and hold (small fl ame) button to decrease fl ame height or to set the appliance a...

  • Page 13

    13 remote control operation setting the on / off temperatures • brie fl y press set button to scroll to temp (sun) mode. Hold the set button until the temp fl ashes. • press (large fl ame) button to increase the daytime set temperature. • press (small fl ame) button to decrease daytime set temperatu...

  • Page 14

    14 remote control operation setting program timers • you can program two periods of time between 12:00 am and 11:50 pm in each 24-hour cycle. • the programs p1 and p2 must be set in the following order during a 24-hour cycle: , , and . • the icon indicates the beginning of the period (on) and the ic...

  • Page 15

    15 remote control operation automatic turn down automatic shut off low battery indication handset / receiver match remote handset: the battery icon will show when the battery needs to be replaced. Replace with one 9 v alkaline battery. Battery box: three short ‘beeps’ will sound when the motor turns...

  • Page 16

    16 required kits* fuel beds (choose one) 1505dwk—long beach drift wood kit 1510dgm—murano decorative glass effect 1512mbs—murano bead set ceramic liners (choose one) 1615fbl—linear fluted black panel set 1625ebl—linear enamel black panel set (includes in fi ll panels) trims (choose one) 1550—linear ...

  • Page 17

    17 lighting instructions for your safety, read before lighting warning: if you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand, remote control, or wall swit...

  • Page 18

    18 state of massachusetts carbon monoxide detector/vent terminal signage requirements for all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the commonwealth...

  • Page 19

    19 (d) manufacturer requirements - gas equipment venting system not provided. When the manufacturer of a product approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the fl ue gases, but identi fi es “special venting systems”, the following requirements ...

  • Page 20

    20 x valve access side ratings model n p gas natural propane altitude (ft.)* 0-4,500 feet* input maximum (btu/h) 30,000 26,000 input minimum (btu/h) 18,000 18,500 manifold pressure (in w.C.) 4.0” 10.0” minimum supply pressure (in w.C.) 5” 11” maximum supply pressure (in w.C.) 10” 14” main burner inj...

  • Page 21

    21 overview fire on/off wall switch (20-foot wire length) (supplied, recommended) installation in opposite room suggested. 1600 heater combustible floor framing—see framing requirements 1/2 inch thick non-combustible cement board – not supplied supplied as horizontal side outlet, fi eld convertible ...

  • Page 22

    22 center line 1-3/8” (35 mm) m in. 44-1/2” (1130 mm) to t op of c ement boar d m in. 43” (1093 mm) to underside of header 1270rbk duct kit inlet (remove plate) gas line access point zero clearance stand-offs battery box zero clearance stand-offs header 6-5/8” dia. Venting field- convertible from si...

  • Page 23

    23 bottom of unit 0 2” 4” 6” 8” 10” 12” face of 1/2” thick non-combustible cement board do not put furniture or objects within 36” (914 mm) of front of appliance mantel projection (from face of cement board) mantel height (from bottom of unit) fireplace opening fireplace opening ceiling 24” m in. T ...

  • Page 24

    24 39-11/16” fireplace opening wall min. 4” to wall or combustible face of finished wall fireplace combustible sidewall / mantel leg—top view mantel & hearth clearances qualified installer.

  • Page 25

    25 between underside of header and bottom of firebox no hearth required. If using a hearth, see page 23. 1/2” thick non-combustible cement board required above, on each side and below engine opening (not supplied) - see page 36. Note: height of cavity may be affected by vent configuration with clear...

  • Page 26

    26 43” (1093 mm) t o underside of c ombustible ca vit y * 55-1/2” (1410 mm) with 12” v e nt pipe * 45” (1143 mm) 37” (940 mm) required clearance to vertical pipe is within stand-off space 12” pipe section 14-1/2” (369 mm) stand-off 9-3/8” (238 mm) 19-1/4” (489 mm) fireplace * 58” (1473 mm) with 12” ...

  • Page 27

    27 10” (254 mm) 10” (254 mm) align the vent center to the center of the frame venting top or side outlet this unit is supplied with a top vent outlet which can be fi eld-converted to a side vent outlet. See appliance preparation section for more information. Vent material this unit is approved for i...

  • Page 28

    28 horizontal termination 2-piece wall thimble pipe length horizontal termination 2-piece wall thimble pipe length pipe length pipe length pipe length 90˚ elbow ceiling firestop attic firestop attic insulation shield flashing storm collar vertical termination pipe length 90˚ elbow 90˚ elbow co-axial...

  • Page 29

    29 2 4 6 8 10 12 14 16 18 20 vertical rise (ft) horizontal run (ft) 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 4 x 90º elbows maximum (or equivalent) position #5 example 1 no installation position #4 position #3 position #2 position #1 allowable co-axial vent con fi gurations with res...

  • Page 30

    30 position #1 position #2 position #3 position #4 position #5 inside fi rebox— roof venting port restrictor the restrictor is located in the roof of the fi rebox hidden above the top liner panel. Adjust the restrictor before installation of the top liner panel. Should subsequent adjustment be requi...

  • Page 31

    31 v g a min. 72” max. 72” alcove detail (open on one side) normal ceiling/soffi t clearances apply. Key vent terminal locations - minimum distances minimum clearance inches cm a clearance above grade, verandah, porch, deck or balcony 12 30 b clearance to window or door that may be opened 12 30 c cl...

  • Page 32

    32 roof pitch minimum "h" (feet) flat to 7/12 1' over 7/12 to 8/12 1.5' over 8/12 to 9/12 2’ over 9/12 to 10/12 2.5’ over 10/12 to 11/12 3.25’ over 11/12 to 12/12 4’ over 12/12 to 14/12 5’ overhang should not extend beyond vent if within 48” of termination cap horizontal overhang vertical wall min. ...

  • Page 33

    33 10-1/2” (267 mm) 7-1/2” (191 mm) 7-1/8” (181 mm) 3” (76 mm) flashing 2 x 3” liners 3” min. Bend radius co-linear adapter 2 x 3” liners co-linear adapter linear engine approved co-linear termination or approved note: appliance needs to be framed as indicated in previous sections. All zero clearanc...

  • Page 34

    34 fold lines other side standoffs outlet side standoffs only quali fi ed licensed or trained personnel should install this appliance. Installation unpack appliance beware of sharp edges! Wear gloves! 1. Remove the cardboard wrapping and the wood pallet from the appliance and discard. 2. Unpack any ...

  • Page 35

    35 non- combustible m aterials onl y read instruc tions m atÉria ux inc ombustibles seulement consul tez le guide d ’inst alla tion fl ush front face of appliance mounting tabs (3) appliance fl ush to framing on both faces valve access side installation remove top outlet (6 screws) install heat shie...

  • Page 36

    36 1/2” (13mm) thick non-combustible cement board gypsum board up to perimeter of cement board min. 9-1/4” (235 mm) min. 44-1/2” (1130 mm) min. 20-1/2” (521 mm) 14-3/4” (375 mm) board flush with bottom of heater; add extra if overlapping framing. 40” (1016 mm) min. 53” (1346 mm) joints preferred at ...

  • Page 37

    37 section views window frame bottom railing battery slider valve remove the window on the valve access side only installation remove window the windows are held in place by a spring-loaded lever on each side. Remove the window on the valve access side only. 1. Locate the levers on each side of the ...

  • Page 38

    38 x 2-3/4” (70 mm) gas line access valve access side of the appliance 5-1/2” (140 mm) set-up gas supply the gas supply inlet connec- tion is a 3/8” npt male con- nector located on the left hand side of the fi rebox. The unit is supplied with a stainless steel fl ex line to allow the appliance to be...

  • Page 39

    39 manifold test pressure valve inlet pressure pressure testing installation pressure test points the minimum supply pressure is given in the section specifi cations of this manual—page 20. All piping and connections must be tested for leaks af- ter installation or servicing. All leaks must be corre...

  • Page 40

    40 enamel panel— rear view fire side in fi ll panel installation install liners the liners install in the manner outline below. Unpack them carefully as they are fragile. Ceramic panels 1. Identify the top and bottom ( fi re) sides of the top panel, then slide it between the top panel support bracke...

  • Page 41

    41 installation install long beach driftwood kit material required • middle platform brackets (supplied with appliance) • vermiculite platform (supplied with appliance) • small container to distribute vermiculite (non included) • long beach driftwood kit, which contains: ◊ 5 logs ◊ 6 pebbles ◊ 1 bag...

  • Page 42

    42 discard this log from the log pack use this log instead, provided with the appliance x wrong right x installation logs and rocks the log and rocks pack contains a center log which is not being used in this installation. Another log is provided with the fi replace in a small separate box and shoul...

  • Page 43

    43 warning choking hazard! Ensure that the fi replace area is clear of vermiculite particles as these could be ingested by small children. Vacuum area after installation. 6. Some vermiculite may be added outside the burner on the platform if desired. 7. Place the rocks on the platform as shown below...

  • Page 44

    44 warning choking hazard! Ensure that the fi replace area is clear of fi re glass particles as these could be ingested by small children. Vacuum area after installation. ! Installation 7. Some fi reglass may be added on the platform to cover the edge of the burner and in the space in front and behi...

  • Page 45

    45 warning choking hazard! Ensure that the fi replace area is clear of fi rebeads as these could be ingested by small children. Vacuum area after installation. ! Installation install murano beads set material required • middle platform brackets (supplied with appliance) • small container to distribu...

  • Page 46

    46 section views window frame bottom railing battery slider valve re fi t window 1. To re fi t the window, place it in its bottom railing and push its top against the fi rebox. Ensure there is no glass or vermiculite particles in the bottom railing. 2. While you hold it, pull the side levers back in...

  • Page 47

    47 the receiver and battery box carrier are located inside the front panel of the appliance (valve access side shown). Battery box in carrier receiver caution do not use a screwdriver or other metallic object to remove the batteries from the battery box! This could cause a short circuit to the recei...

  • Page 48

    48 battery box connection reset button velcro appliance’s front panel set-up remote control the receiver and the handset of the remote control sys- tem must be initially synchronized before the fi rst use. 1. Insert one 9 v alkaline battery in the handset. 2. Locate the reset button on the top side ...

  • Page 49

    49 remove front middle platform support accessing air shutter close open injector elbow bracket, burner side injector elbow foam gasket air shutter setting air shutter: loosen screw to adjust and re-tighten afterwards. Install trim and barrier screen install the trim chosen by the customer for their...

  • Page 50

    50 packing contents: 1 wall bracket a 2 screws b 1 screw c 2 wall anchor d 1 spacer e (detach before assembly) 1 wall bracket f switch plate alternative 1 alternative 2 alternative 3 install remote control handset wall holder the remote control kit for this fi replace comes complete with a wall-moun...

  • Page 51

    51 wiring diagram wall switch kit connector gv60 wiring diagram remote battery box 4 aa batteries qualified installer.

  • Page 52

    52 approved venting components approved direct vent suppliers for valor models 1100, 1150, 1200 5 , 1500, 1600 5 and 1700 venting parts description venting parts code / availability by manufacturer dura-vent selkirk icc excel direct secure vent rlh industries amerivent miles industries bdm terminati...

  • Page 53

    53 approved venting components venting parts description venting parts code / availability by manufacturer dura-vent selkirk icc excel direct secure vent rlh industries amerivent miles industries bdm pipes 4” x 6 5/8” ( id x od ) 6” long galvanized 46dva-06 4dt-06 tc-4dl6 sv4l6 — — — 94610606 black ...

  • Page 54: Lor

    54 warr an ty pr og ram warr an ty pr og ram va lor co m fo r t va lor co m fo r t va lor co m fo r t warranty 1. Extended warranty coverage for a period of up to ten (10) years, miles industries ltd., (the “company”) or its appointed distributor will at its option pay the initial purchaser for the ...

  • Page 55

    55 spare parts code description part number 1 heat shield 4003049 2 45 degrees fl anged elbow 0945m 3 top stand-offs (4) 4002985 3a side stand-offs (4) 4003527 4 liner top panel (all liners) 4003522 5 restrictor plate 4003017 6 take-off cover 4003046 7 lh window latch assembly (2) 4002770 8 rh windo...

  • Page 56

    56 spare parts 13 1 2 3 4 7 9 9 7 10 11 12 12 8 8 57 6 5 73 73 58 74 59 60 61 62 69 68 67 66 65 64 63 14a, 14b 15 16 17 18 19-23 24-25 26 27a, 27b 28 29 30 31 32 33 34 36a, 36b 35 38 37 41 40 42 39 47 45 46 43 44 3a owner’s information.

  • Page 57

    57 spare parts 52 51 50 49 48 53 54 56 55 70 72 71 owner’s information.

  • Page 59

    Thank you ... For purchasing a valor by miles industries. Your new radiant gas heater is a technical appliance that must be installed by a quali fi ed installer. Please fi ll in the information below. The information provided will be used for customer records only. Online warranty registration at ww...

  • Page 60

    Tape shut thank you for choosing a valor product postage needed miles industries ltd. 190 - 2255 dollarton highway north vancouver, bc v7h 3b1 canada fold here online warranty registration at www.Valor fi replaces.Com.