Valor 3290 Installation And Servicing

Manual is about: RADIANT/CONVECTOR GAS FIRES

Summary of 3290

  • Page 1

    Contour model 3290 - teak finish & silhouette model 3291 - mahogany finish model 3297 - black ash finish radiant / convector gas fires installation & servicing instructions this appliance is for use with natural gas (g20) at a supply pressure of 20mbar (8in w.G.) this appliance is for use in the uni...

  • Page 2

    2 list of contents page appliance dimensions 2 appliance data 3 general installation requirements 3 unpacking & pre-installation preparation 5 • carton contents 5 • fireplace flue pull check 5 • preparing appliance for installation 5 • closure plate fitting 6 appliance installation 7 • hearth instal...

  • Page 3

    3 1. Appliance data this appliance does contain not any component manufactured from asbestos or asbestos related products. The appliance data label is on the inner face of the metal case at the left side. It is visible when the outer case is removed. Gas: natural (g20) inlet pressure: 20mbar (8in. W...

  • Page 4

    4 2.3.3. Precast flue the appliance can be installed to a fireplace that has a precast concrete or clay flue block system conforming to bs1289. The appliance is suitable for installations conforming to older versions of bs1289 as well as the current edition. The flue blocks must have a minimum width...

  • Page 5

    5 affect the safe performance of the appliance. Note the spillage test requirements detailed further on in this manual. If the fan is likely to affect the appliance, the appliance must not be installed unless the fan is permanently disconnected. 2.12. In the united kingdom no special ventilation bri...

  • Page 6

    6 3.4. Fitting the closure plate (figures 5,6 & 7) 3.4.1. If a centre gas pipe connection is required cut an opening at the bottom of the closure plate. (the gap between the pipe and the opening in the closure plate should be sealed with tape after connection,) 3.4.2. Hearth mounting (figure 6) the ...

  • Page 7

    7 4. Appliance installation 4.1. Installing to a hearth 4.1.1. Place the fire centrally on the hearth making sure that the spigot lines up with the spigot hole in the closure plate. Gently slide the appliance into place. The spigot must enter the closure plate to a depth of at least 25mm (see figure...

  • Page 8

    8 extractor fan is installed in the same room as the appliance or a connecting room, check that spillage does not occur with the fan operating and all doors and other openings between the fan and the appliance open. If the smoke is drawn into the appliance, continue with the installation. If the tes...

  • Page 9

    9 7. Servicing & parts replacement • always turn off the gas supply and make sure that the appliance is cool before commencing any servicing. • always test for gas soundness and spillage after servicing the appliance. • it is recommended that, at least once a year, the appliance is disconnected and ...

  • Page 10

    10 7.7. To grease the gas tap 7.7.1. Remove the gas tap complete with piezo generator - see section 7.5. 7.7.2. Remove the two screws and shakeproof washers securing the piezo generator. Carefully lift the piezo generator clear together with the gas tap head. 7.7.3. Remove the spindle and spring fro...

  • Page 11

    11 valor heating erdington, birmingham b24 9qp because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. ©valor heating.