Valor 3290 Installation And Servicing - page 8
8
extractor fan is installed in the same room as the
appliance or a connecting room, check that spillage
does not occur with the fan operating and all doors
and other openings between the fan and the
appliance open. If the smoke is drawn into the
appliance, continue with the installation. If the test is
not satisfactory,
Disconnect the appliance and advise
the customer of the cause of failure
5.3
FINAL ASSEMBLY
5.3.1
Fit the bottom trim using the two knurled screws to
secure it to the side feet (see figure 9)
5.3.2
Remove the control knob.
5.3.3
Refit the outer case making sure that the metal
flanges at the top of the wood case locate fully in the
brackets at the top of the back panel.
5.3.4
Refit the outer case retaining screws at the bottom
sides.
5.3.5
Refit the control knob.
6. FINAL REVIEW
6.1.
Recheck the operation of the control.
6.2.
Visually inspect the appliance. Clean off any marks
incurred during installation.
6.3.
Advise the customer how to operate the appliance.
6.4.
Advise the user that the appliance can be lit with a
match if necessary by inserting it through the central
opening at the bottom of the radiant box.
6.5.
Advise that the dressguard can be removed to replace
the radiants. Show the customer how to remove the
guard.
6.6.
Advise that any cleaning must only be carried out
when the fire is off and cold.
6.7.
Mention that the radiants may become brown with
use, that this is quite normal and has no adverse
effect.
6.8.
Recommend that the appliance should be serviced
and the chimney inspected by a competent person at
least annually.
6.9.
Hand these instructions and the user's instructions to
the customer.
Figure 8. Smoke match tube position
Figure 9 Bottom trim