Valor 417 Owner's Manual

Other manuals for 417: Installation And Servicing Manual
Manual is about: ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE

Summary of 417

  • Page 1

    Ultimate inset live fuel effect gas fire model 417 owner guide the natural gas model is for g20 at a supply pressure of 20mbar the propane gas model is for g31 at a supply pressure of 37mbar these appliances are for use in the united kingdom (gb) and the republic of ireland (ie) only these appliance...

  • Page 2

    2 contents page cautions 2 hearth dimensions & clearances 3 gas consumption 3 operation the fire 4 cleaning 5 fuel bed refitting 5 maintenance 8 thank you for choosing this valor gas appliance. This fire has been designed to give years of trouble-free service. To maintain its optimum performance, ad...

  • Page 3

    3 please observe the caution statements on the previous page. Gas consumption natural gas appliances have a maximum gas input at the high setting of 6.0kw (gross) and a minimum gas input at the low setting of 2.2 kw (gross). Propane gas appliances have a maximum gas input at the high setting of 6.1k...

  • Page 4

    4 operating the fire the flame sensing & flue blockage safety system. For your safety, this appliance is fitted with a flue blockage safety device which will shut down the appliance in the event of abnormal flue conditions. This device is not a substitute for an independently mounted carbon monoxide...

  • Page 5

    5 cleaning turn the fire off and allow it to cool before attempting any cleaning. Note that the fire will retain heat for some time after it has been turned off. If large pieces of debris are found anywhere in the fireplace, have the chimney inspected before further use. Metal parts clean the metal ...

  • Page 6

    6 3. Place the rear base coal in the burner compartment behind the front coal. Its rear face should touch the rear ceramic wall (see figure 6). 4. The ceramic side walls are marked at the rear bottom corners “l” (left side) & “r” (right side). Place the side walls against the sides of the fire box a...

  • Page 7

    7 5.2. Place two of the remaining coals in the two outer valleys of the front coal (one each side of the large coals) (see figure 9). Place the left side coal so that you will be able to see the pilot flame below the coal. 5.3. Place the three remaining coals behind and approximately midway between ...

  • Page 8

    8 maintenance debris from the chimney the opening at the back of the appliance must be always kept clear of obstruction. If the chimney has previously been used for coal fires or is of normal construction it is possible that loose mortar and soot can fall behind the appliance. This, in time, may bui...

  • Page 9

    Safety first . Valor fires are ce approved and designed to meet the appropriate british standards and safety marks. Quality and excellence. At the heart of every valor fire. All valor fires are manufactured to the highest standards of quality and excellence and are manufactured under a bs en iso 900...