Valor 530 B-Vent Installation Booklet - page 6
6 of 18
4. SUPPLY GAS
•
All appliances are supplied for installation with natural gas. The supply pressure must be
between the limits shown in section 3.2 of this manual.
•
The supply connection is
3
/
8
’’NPT.
•
The opening for the gas supply line is at the rear left corner of the appliance.
5. PACK CONTENTS
#530EAN Engine unit (For all appliances)
1
Appliance engine unit fitted with
window
2
Restrictor plates type #1*
2
Restrictor plates type #2*
2
Restrictor plates type #3*
1
Port cover
1
Gas inlet pipe connection adapter
2
Wall spacer brackets*
1
Firebox ceramic rear wall
2
Firebox ceramic side walls
5
Ceramic logs
1
Switch unit
2
Wire clips
4
1.5V AA batteries
4
Wood screws
4
Wall plugs
2
Thread cutting screws
*
Not required for B-vent installations
#552BVK B-Vent Conversion Kit
1
B-vent adapter unit with vent switch
1
Thermocouple interrupter
1
Case rear cover plate
2
“P” clips (for wire fastening)
#531CSB, #532ESB & #533ESG President
Free Standing Case Alternatives
Top pack
1
Top casting
1
Top infill plate
Sides pack
1
Front casting unit
2
Side casting units
1
Top air deflector
1
Switch mounting bracket
2
Self-cutting screws
4
Machine screws
4
Washers
#553RCK Remote control unit (Additional
option)
1
Receiver unit
1
Remote control hand unit
4
1.5V AA Batteries
1
9V Battery
#557WSK Wall switch unit (Additional
option)
1
Wall switch unit
1
Battery holder
1
20ft (6.1m) length of connection wires
2
Screws for wall switch
#555CFK Circulating fan kit (Additional
option)
Details are with the kit
#554LPK LPG conversion kit
Details are with the kit
Take care when removing the contents from the packaging to prevent damage. Check that all the
contents are in the packs and are undamaged.