Valor 739ILP Owner's Manual

Manual is about: DV Gas Insert

Summary of 739ILP

  • Page 1

    L egend 4001514-12 ©2012, miles industries ltd. Manufactured by miles industries ltd., british columbia, canada www.Valorfi replaces.Com dv gas insert 739iln/p (logs) & 739irn/p (rocks) installation and owner’s manual warning: if the information in these instructions is not followed exactly, a fi re...

  • Page 2

    Safety precautions ............................................3 safety and your fireplace .................................4 owner’s information ..........................................5 remote control operation.................................9 options ..............................................

  • Page 3: Safety Precautions

    3 safety precautions children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be su...

  • Page 4: Safety And Your Fireplace

    4 safety and your fireplace safety and your fireplace please follow these important child safety precautions and recommendations, • parts of your valor fireplace become extremely hot while in operation. • the glass viewing window temperature can exceed 500 f at full capacity. Momentary contact with ...

  • Page 5: Do Not Put

    5 operating your fireplace for the first time when operating your new fi replace for the fi rst time, some vapors may be released due to the burning of curing compounds used in the manufacture of the appliance. They may cause a slight odor and could cause the fl ames to be the full height of the fi ...

  • Page 6: Warning

    Owner’s information cleaning important - glass cleaning - mineral deposits one of the by-products of the combustion process in a gas appliance is a mineral which can show up as a white fi lm on the ceramic glass of the viewing door. The composition of the deposit varies with location and time. It is...

  • Page 7: Warning

    Owner’s information checks a periodic check of the pilot and burner fl ames should be made. Check after the fi re has been on for at least 30 minutes. The pilot fl ame must cover the tip of the thermocouple probe. The main burner fl ame pattern will vary from appliance to appliance depending on the ...

  • Page 8

    Owner’s information on off manual on/off switch servicing if any attention is required for your appliance, contact your supplier quoting the model number. It will be helpful if the appliance’s serial number can also be quoted. This number is on the rating plate, which is located under the burner. Th...

  • Page 9

    Remote control operation when the pilot is off, it will take 2 minutes before it can be lit again. To turn on appliance to turn off appliance flame height adjustment • on the valve, turn man knob on the on, full counterclockwise position. • place on/off switch (if equipped) in i (on position). Stand...

  • Page 10

    Remote control operation setting the time setting ºc/24-hour or ºf/12-hour clock modes of operation note: manual mode can also be reached by pressing either the (large fl ame) or the (small fl ame) buttons. • press and hold (small fl ame) button to decrease fl ame height or to set the appliance at p...

  • Page 11

    Remote control operation setting the on / off temperatures • briefl y press set button to scroll to temp (sun) mode. Hold the set button until the temp fl ashes. • press (large fl ame) button to increase the daytime set temperature. • press (small fl ame) button to decrease daytime set temperature. ...

  • Page 12

    Setting program timers • you can program two periods of time between 12:00 am and 11:50 pm in each 24-hour cycle. • the programs p1 and p2 must be set in the following order during a 24-hour cycle: , , and . • the icon indicates the beginning of the period (on) and the icon indicates the end of the ...

  • Page 13

    Options venting (required) see approved venting components section. Inner front (required) see your dealer for your choice of inner fronts. Outer surrounds, trims & frets (optional) see your dealer for your choice of outer surrounds and trims and frets. Optional accessories 755cfk—fan kit 1265wsk—wa...

  • Page 14

    Lighting instructions warning : if you do not follow these instructions exactly d¿uhruh[sorvlrqpd\uhvxowfdxvlqj surshuw\gdpdjhshuvrqdolqmxu\ruorvvriolih )lj )lj )lj$ for your safety, read before lighting a. This appliance has a pilot which must be lighted by hand or by remote control. Follow these i...

  • Page 15

    X x ratings model ng lpg gas natural propane altitude (ft.)* 0-4,500 feet* input maximum (btu/h) 26,000 24,000 input minimum (btu/h) 6,500 13,000 manifold pressure (in w.C.) 3.6 10.0 minimum supply pressure (in w.C.) 5.0 11.0 maximum supply pressure (in w.C.) 10.0 14.0 main burner injector marking 8...

  • Page 16: Warning

    Overview this appliance may only be installed in an existing unaltered, functioning solid-fuel burning fi replace with a working fl ue and constructed of non-combustible material. Do not install into combustible construction. This appliance is not approved for installation with a zero clearance kit....

  • Page 17

    28-5/8” (727 mm) 19-1/2” (495 mm) 12” (305 mm) or 12-5/8” (321 mm) varies with outer trim options 9-3/8” (238 mm) or 10” (254 mm) varies with outer trim options 20” (508 mm) gas inlet gas connection electrical inlet optional outer trim or surround sold separately x y dimensions cavity check that mas...

  • Page 18: Warning

    A b do not put furniture or objects within 36” (914 mm) of the front of appliance 9” (229 mm) sidewall clearances minimum distance from side of appliance (liner box) to combustible wall: 9” (229 mm). Sidewall warning some materials or items, although safe, may discolor, shrink, warp, crack, peel, so...

  • Page 19

    Terminal cap flashing 2 x 3” fl ex liners—see venting table for length allowed typical vent installation see list of approved venting accessories on page 32 of this manual. Vent location the vent terminal must be located through the roof. This direct vent appliance is designed to operate when an und...

  • Page 20

    Installation planning existing fireplace preparation a few points must be considered before inserting the 739i into an existing fi replace cavity. Generally, no modifi cations are allowed to the existing fi replace that will compromise the integrity of the existing fi replace. Components that are bo...

  • Page 21

    Unpacking the appliance beware of sharp edges! Wear gloves! 1. Unpack the appliance. 2. Unpack any loose items from around the appliance and check against the pack content list provided in the documentation package. 3. Remove the window and set aside in a safe place to avoid damage—see next page. 4....

  • Page 22

    Electrical outlet fan cavity appliance preparation window removal the window is held in place by four spring-loaded bolts, two at the top and two at the bottom. 1. To remove the window, turn each bolt a quarter turn to disengage the bolt pin. 2. Gently pull the bottom of the window outward and unhoo...

  • Page 23: Option 2B

    Venting installation important: this appliance’s venting system is room sealed and therefore, does not require room air to be used in the combustion process. 1. Rough-in two 3” diameter vent liners into the existing chimney system from the roof. Be careful not to tear or damage the liners in the pro...

  • Page 24

    Supply pressure test tapping manifold pressure test tapping supply gas installation the gas supply inlet connection is a 3/8” npt female connector and is located on the left hand side of the control valve. Use only new black iron or steel pipes or copper tubing if acceptable—check local codes. Note ...

  • Page 25

    Rotate anchor up and insert panel position of panel in relation to burner plate edge of burner plate side panels should be parallel to edge of burner plate panels installation the following guidelines apply for all liners. 1. Inside the fi rebox, on the top of each side, release the screw of the sid...

  • Page 26

    Ceramic logs installation (739il) unpack the ceramic logs very carefully to avoid damaging the fragile material. Install the logs as shown below. Please note that the position of the logs is critical to ensure proper performance of the appliance. 1. Spread the decorative charcoals on each side of th...

  • Page 27

    Top bottom 1. Install the front support platform in the fi rebox carefully sliding it down between the burner and the front bottom edge for the fi rebox while avoiding scraping the side ceramic panels. 2. Place the rock ceramic base on the log support behind the burner. The front bottom of the base ...

  • Page 28

    Ceramic rocks installation (739ir) 4. The underside of each ceramic rock is identifi ed by a number and a specifi c protruding positioning triangle. Install the six rocks from left to right starting with rock no. 1. 5. Place the glass panel in its cavity formed by the front support and the ceramic p...

  • Page 29

    Bottom of window (wider frame) window refi tting 1. To refi t the window, place the window against the fi rebox’s opening frame. Make sure that the wider part of the window frame is at the bottom. 2. While you hold it, push in and turn the two bottom spring-loaded bolts a quarter turn to engage thei...

  • Page 30

    Packing contents: 1 wall bracket a 2 screws b 1 screw c 2 wall anchor d 1 spacer e (detach before assembly) 1 wall bracket f switch plate alternative 1 alternative 2 alternative 3 open open close close ng flashback shield (for lpg only) lpg air shutter slider open close lpg ng air shutter slider & c...

  • Page 31

    Optional wall switch kit 1265wsk connector red yellow gv60 wiring diagram wiring diagram 31 qualified installer.

  • Page 32

    Approved direct vent suppliers for valor models 700, 739, 780, 785 and rf24dv venting parts description venting parts code / availability by manufacturer dura-vent selkirk icc excel direct secure vent rlh industries amerivent miles industries t ermination caps v ertical standard co-axial 46dva-vc 4d...

  • Page 33: Lor

    Warranty 1. Extended warranty coverage for a period of up to ten (10) years, miles industries ltd., (the “company”) or its appointed distributor will at its option pay the initial purchaser for the repair of, or will exchange the following parts or components which are found to be defective in mater...

  • Page 34

    Code description part number 1 exhaust slide assembly 4001133 2 exhaust slide gasket 4000176 3 fan closure plate 4001136 4 port cover 4001820 5 rock support (739ir) 4001768 5 log support (739il) 4001841 6 side bricks anchors (2) 4001283 7 top mounting bracket 4000136az 8 side mounting brackets (2) 4...

  • Page 35

    Spare parts code description part number right fluted panel (739ir) 4001813 right brick panel (739il) 4001810 68 glass panel (739ir) 4001836 69 front support—platform (739ir) 4001835ah 70 ceramic platform (739ir) 4001832 71 log set complete (739il) 4001696 72 rear log (739il) 4001697 73 front left l...

  • Page 36

    Spare parts ng lpg 18 20 25 21 22 23 24 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 42 45a, 45b 14a ng lpg 13a 47 48 49 50 51 52 53 49a 71 72 73 74 75 76 77 78 44 55 56 57 58 59 60 61 54 62 63 66 67 65 64 68 69 70 36 owner’s information.

  • Page 37

    Thank you ... For purchasing a valor by miles industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed installer. Please fi ll in the information below. The information provided will be used for customer records only. Online warranty registration at www...

  • Page 38

    Tape shut thank you for choosing a valor product postage needed miles industries ltd. 190 - 2255 dollarton highway north vancouver, bc v7h 3b1 canada fold here online warranty registration at www.Valorfi replaces.Com.