Valor 739ILP Owner's Manual - Warning
Owner’s Information
Checks
A periodic check of the pilot and burner fl ames should
be made. Check after the fi re has been on for at least
30 minutes. The pilot fl ame must cover the tip of the
thermocouple probe. The main burner fl ame pattern will
vary from appliance to appliance depending on the type of
installation and climatic conditions.
The appliance area must always be kept clear and free
from combustible materials, gasoline and other fl ammable
vapors and liquids.
Inspect the vent terminal outdoors regularly to make sure
that snow, trees, bushes, leaves, or other objects do not
obstruct it.
Examine the vent system and terminal regularly. We
recommend annually.
Remote Control Handset Wall
Holder
Your fi replace equipment includes a wall
holder to store the handset. If it hasn’t be
installed, refer to the instructions further
on in this manual for the installation.
Batteries
Low battery signal: see page 13.
BEFORE changing the batteries, turn off the valve
using the manual On/Off switch —
see instructions
next page.
The appliance uses four 1.5 V AA alkaline batteries for
its remote control receiver and one 9 V alkaline battery
for its handset. Batteries should last one to two seasons,
depending on usage. Removing the batteries in the off-
season will extend the battery life. Should the batteries
loose power, the control may be operated by manually
turning the control knob at the valve or by turning off the
valve at the switch.
To replace the batteries in the remote control
receiver
:
1. The receiver is located to the left of the valve and it
is retained to the fi rebox by a Velcro tab. Grab the
receiver and pull it out from its location.
2. Slide and remove the receiver cover.
3. Replace the 4 AA batteries.
4. Replace the cover.
5. Put the receiver back in its position pushing it in so
it attaches to the Velcro tab.
Lighting, Operation and Rating Information
The Lighting, Operation and Rating information is located
on a plate under the burner. To access the plate, remove the
fret or access panel, grab the plate and take it out to read it.
There is important information on both sides of the plate.
Pilot Flame can be seen between logs (739IL) or left of the fi rst
rock (739IR)
Pilot
Flame
Correct
Flame
Picture—
Logs
Correct
Flame
Picture—
Rocks
Thermocouple
Probe must be
in Flame
CAUTION
DO NOT USE
a screwdriver or other metallic object to
remove the batteries from the receiver or the handset!
This could cause a short circuit to the receiver.
WARNING
DO NOT ATTEMPT TO CHANGE THE BATTER-
IES WHILE THE FIREPLACE IS STILL HOT!
Let
the fi replace cool fi rst before touching it.
WARNING
!
WARNING
DO NOT ATTEMPT TO TOUCH THE DATA PLATE
WHILE THE FIREPLACE IS STILL HOT!
Let the
fi replace cool fi rst before touching it.
WARNING
!
Rock fuel bed
A black discoloration may form over time at the front
bottom of the 6-rock original fuel bed; this deposit
can be burned off by running the fi replace on a low
to medium setting fi re for 30 to 45 minutes. This
discoloration is unavoidable and will re-form again.
7
OWNER’S
INFORMATION