  • Page 1

    4000192-12 p ortrait decorative warning: if the information in these instructions is not followed exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. What to do if you smell gas • do not try to light the appliance. • do not touch any electrical switch; ...

  • Page 2: Do Not Put

    2 designed and manufactured by miles industries ltd. 190 – 2255 dollarton highway, north vancouver, bc, canada v7h 3b1 tel. 604-984-3496 fax 604-984-0246 www.Valorfireplaces.Com © copyright miles industries ltd., 2011 2 we recommend that our gas hearth products be installed and serviced by professio...

  • Page 3

    33 table of contents safety and warning information ..............................................................4 specifications ............................................................................................5 options ......................................................................

  • Page 4

    4 young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or s...

  • Page 5

    55 safety and warning information specifications approvals and codes this appliance is certified to ansi z21.50b–2009/csa 2.22b–2009 vented gas fireplaces standard for use in canada and usa. The appliance complies with csa p4.1-09 testing method for measuring annual fireplace efficiencies. The insta...

  • Page 6

    66 21-1/2” 39” 31” 30-1/4” 38” 34” 923 adorn 539 windsor arch with plate 549 windsor arch no plate choice of fronts note : the 539/549 fronts require a 540 wdk wire dress guard with the 922 heater. Cast iron tolerances – due to the nature of cast iron, dimensional consistency may vary from one unit ...

  • Page 7

    77 location & clearances this appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. Note: the state of massachusetts requires that any flue damper must be removed or permanently welded in the open position. The appliance can be installed in the following ...

  • Page 8

    8 ng air shutter slider & cover open open close close ng flashback shield (for lpg only) lpg air shutter slider open close lpg 8 • optional 975zck zero clearance kit must be used when installing the 922 fireplace into any application other than as an insert into an approved solid-fuel burning firepl...

  • Page 9

    99 appliance preparation install base coal support install base coal support (packed loose) to back of firebox using 3 screws as shown below. Remove burner module (optional) in some cases, to make gas piping easier, it may be convenient to remove the burner module from the firebox—note the location ...

  • Page 10

    10 10 gas supply installation • the appliance is supplied for supply gas connection at the left hand side of the case. There is also a gas line access at the rear of the firebox for insert applications. The zero clearance kit does not have access at the rear. Supply line connection to the flexible a...

  • Page 11

    11 11 firebox installation (insert application only) refer to 975zck installation manual for zc firebox installation. To aid chimney liner connection, it may be necessary to first remove the vent collar connector from the top of the firebox—see figure below. 1. Remove the burner module from the fire...

  • Page 12

    12 12 remote control installation caution! Do not fit the batteries into the remote control receiver until the wires are connected to the burner control unit, as a short circuit could result in the destruction of the electrical components. • connect the wiring harness to the receiver box, by pushing...

  • Page 13

    13 13 ceramic fuel bed installation ceramic walls installation 1. Locate the ceramic rear wall on top of the base coal support as shown. 2. Insert the right hand sidewall at an approximate 30-degree angle between the firebox side and the burner. Swing the top of the sidewall to the vertical position...

  • Page 14

    14 14 1 2 4 5 3 ceramic coals installation 1. Rest the base coal on the supports just behind the burner and let it rest against the base coal support at the back of the firebox. 2. Place the left front coal in position behind the metal lip at the front of the firebox. The side projection on this coa...

  • Page 15

    15 15 923acf adorn cast front installation 1. Carefully lift the casting. Place it against the fireplace front surface so that the retaining strip at the back of the casting is above the two upper retaining brackets at the top of the convection box. 2. Lower the casting making sure that the rear ret...

  • Page 16

    16 16 operation checks final checks check ignition, pilot stability, burner flames, and the full range of movement of the flame adjustment knob. See owner’s lighting instructions further on in this manual for full details. Aeration adjustment as described in manual, burner aeration is adjustable. Fo...

  • Page 17

    17 17 owner’s information please read the safety information on page 4 of this manual. Operating your fire the operating instructions are also on a chained plate inside the control access door. For your safety this appliance is fitted with a flame supervision device which will shut off the gas suppl...

  • Page 18: Lighting Instructions

    18 18 for your safety read before lighting warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot, which must be lighted by hand. When lighting the pilot, follow these instructio...

  • Page 19: Lor

    19 19 warranty 1. Extended warranty coverage for a period of up to ten (10) years, miles industries ltd., (the “company”) or its appointed distributor will at its option pay the initial purchaser for the repair of, or will exchange the following parts or components which are found to be defective in...

  • Page 20

    20 20 replacement parts code description part. No. 1 drafthood retainer (2) 4000166 2 spigot slide plate assy 4000199 3 downdraft 4000359 4 top plate 4000332ah 5 mounting brkt adorn x2 4000348 6 switch plate 4000360 7 cable clamp 4000361 8 coal bed support 4000413 9a burner module ng 4000230 9b burn...

  • Page 21

    21 21 replacement parts 922 body 1 2 3 8 4 5 6 7 9a/b 10 11 12 13 14 16a 16b 16c 17a/b 18 19 20 38 37 36 23 22 21 15a/b 24 25a/b 26 27 28 29 41 32 42 31 40 39 34 35 47 52 50 51 49 48 44 45 46 30 33a/b 43.

  • Page 22

    22 22 replacement parts 53 54 57 56 58 55 59 60 61 62 63 64 72 71 70 69 68 67 66 65.

  • Page 23

    Thank you ... For purchasing a valor by miles industries. Your new radiant gas heater is a technical appliance that must be installed by a qualified dealer. Please circle where appropriate - ask your installer or your dealer if in doubt. The information provided will be used for customer records onl...

  • Page 24

    Tape shut thank you for choosing a valor product postage needed were you given all documentation and manuals for your product? Yes no miles industries ltd. 190 - 2255 dollarton highway north vancouver, bc v7h 3b1 canada fold here online warranty registration at www.Valorfireplaces.Com.