    600a735/01 o w n e r g u i d e this owner guide is intended to help you care for your valor gas fire. Please read carefully before using your gas fire and keep for future reference. This owner guide gives sufficient details to enable your gas fire to be operated and maintained. Important. Please kee...

  • Page 2

    2 thank you for choosing valor. All valor gas fires are designed to meet the most stringent quality, performance and safety requirements to provide our customers with many years’ trouble-free service. Your owner guide aims to improve your understanding and appreciation of your valor gas fire by prov...

  • Page 3

    3 safety • soft wall coverings (e.G. Embossed vinyls etc.) are easily affected by heat. They may, therefore, scorch or become discoloured when close to a heating appliance. Please bear this is mind when having a heating appliance installed and when redecorating. • as with any gas fire, this applianc...

  • Page 4

    4 general specification the fire has a maximum gas input of 5.36kw (18,300 btu/h). This is equal to approximately 5.5 hours use for one therm. Overall dimensions height 662mm width 657mm depth 284mm (excluding flue spigot) operation the flame sensing & flue ventilation monitoring system for your saf...

  • Page 5

    5 fig. 6 window frame fixing fig. 5 window removal fig. 4 case front removal fig. 3 lighting with a spill lighting with a spill: in the unlikely event of failure of the ignition spark, the fire can be lit by inserting a long spill at the position show in fig.3 while the control knob is turned to the...

  • Page 6

    6 cleaning the coal bed if for any reason the one piece coal bed requires cleaning, proceed as follows:- 1. Remove the case front and window as described above. 2. Carefully lift the coal bed out of the firebox and place it on a piece of cardboard or similar. 3. Carefully vacuum the upper and lower ...

  • Page 7

    7 servicing & maintenance • in order to achieve and maintain high levels of personal safety and performance efficiency it is essential that the opening at the back of the fire and the flue are kept clear of any form of obstruction. It is possible that deposits of mortar or soot could fall and accumu...

  • Page 8

    8 safety first . Valor fires are ce approved and designed to meet the appropriate british standards and safety marks. Quality and excellence. At the heart of every valor fire. All valor fires are manufactured to the highest standards of quality and excellence and are manufactured under a bs en iso 9...