Valor black beauty 466 Owner's Manual - page 4
4
GENERAL SPECIFICATION
The fire has a maximum gas input of 5.36kW (18,300 Btu/h). This is equal to approximately 5.5 hours use for one therm.
Overall Dimensions
Height
662mm
Width
657mm
Depth
284mm
(excluding flue spigot)
OPERATION
The flame sensing & flue ventilation monitoring system
For your safety, this appliance is fitted with a system which will
automatically shut off the gas supply to the fire
•
if the burner flames go out
•
if the flue is blocked
The system includes a probe which senses the heat from the burner
flames. If this probe is cool, the system will prevent any gas flow
unless the control knob is kept held down (See the following lighting
instructions).
The system also includes a detector which will shut off the gas
supply if the flue is faulty causing incorrect ventilation of the exhaust
fumes.
If the flames go out, or if for any reason the fire is turned off, always
wait at least 3 minutes before attempting to relight.
If the monitoring system starts to shut off the gas frequently
please get expert advice. In the United Kingdom call the Valor
AdviceLine on 0345 626341 (local call rates apply).
To light the fire:
1.
Depress the control knob and turn it anti-clockwise
to position 1.
2.
Keep the knob depressed for a few seconds then ,
while keeping the knob depressed, turn slowly to position
2/IGN. If the control knob is inadvertently released before
turning to 2/IGN, turn back to OFF and start again. The
main burner should light at low setting and the decorative
flame burner should ignite (see Fig. 2).
3.
When ignition has been achieved, continue to hold
down the control knob for a further ten seconds to prevent
the flame supervision device from shutting off the gas
supply while its probe warms up, as explained above, then
release it.
If the burner does not remain alight, repeat steps 1 and 2.
4.
Turn the control to select your desired burner
setting (The control knob should be depressed slightly when changing setting positions).
The settings are shown in the following table:-
Control Knob Setting
Burner Appearance
1
Main Burner on Low
Decorative Flame Off
2/IGN
Main Burner on Low
Decorative Flame On
3
Main Burner on Medium Height
Decorative Flame On
4
Main Burner on High
Decorative Flame On
5
Main Burner on High
Decorative Flame Off
To turn off:
Depress the control knob partially, turn clockwise to OFF and release the knob. If any resistance is felt at position 1,
release the downwards pressure on the knob before turning to OFF.
Fig. 2 Burner After Lighting (At Position 2/IGN)
Fig. 1 Control