Valor DZ1GEC Installation Instructions And Owner's Manual - Installation
9
Installation
Plan the power supply. If an existing grounded outlet is near the fireplace, the power cord can
run along the front of the fireplace. If the cord is not long enough to reach the outlet, a grounded
extension cord minimum AWG No. 14 and rated to a minimum of 1875 watts, may be used. If you
plan to cut or drill a hole in the existing fireplace for wiring, it is strongly recommended that you
hire a professional to undertake this step in order to prevent personal injury. To reduce the risk
of fire, do not run the power supply cord under rugs, carpets, etc. Arrange the power supply cord
away from high traffic areas where it may pose a tripping hazard.
New Construction or Renovation
Select a location that is not prone to moisture and is located at least feet (0.9 m) away from
combustible materials such as curtains or drapes, furniture, bedding clothes, paper, etc.
Place the unit in the selected location to see how it will look in the room.
Mark the desired location on the floor and store the unit in a safe, dry and dust free location.
Depending which front will be used, the framing dimensions may be different. See the dimensions
and clearances on pages 6 and 7.
Any new wiring must be done in compliance with local and national codes and other applicable
regulations in order to reduce the risk of fire, electric shock or other injuries. Therefore, it is
strongly recommended that you hire a professional to complete any such work.
Plan your power supply (see options previously described in the previous section “Existing
Fireplace Installation”, no. 4).
Unit Preparation
To accommodate the cast front, the unit needs to be fitted with the framing kit 210EFK.
NOTE:
Depending of which front is installed, some parts of this kit are not used.
See the following pages for the appropriate kit installation as it will differ depending on the front.
Installing the Unit
Position the unit in its frame.
Ensure that the power switch is in OFF position (refer to Operating Instructions on page 17).
Plug the unit in a 15-amp/120 V grounded electric outlet. Use a CSA or UL approved surge
protector.
Position the cast front.
Place the loose coals supplied on the coal ember bed.
NOTE:
The coals pieces provided are real and may stain if not handled carefully.
4.
1.
2.
.
4.
5.
6.
1.
2.
.
4.
5.
WARNING!
This unit is supplied with coal pieces which
are loosely placed on the coal ember bed.
These pieces of coal are small enough to
possibly cause choking if swallowed by young
children.
KEEP SMALL CHILDREN AWAY FROM THE
UNIT AT ALL TIMES.