Valor PORTRAIT 530INI Installation & Owner's Manual - page 17
17
Specifi cations
Approvals and Codes
This appliance is certifi ed to ANSI Z21.88–2014/CSA
2.33–2014 American National Standard/CSA Standard
for Vented Gas Fireplace Heaters for use in Canada
and USA.
The appliance complies with CSA P4.1-09, Testing
method for measuring annual fi replace effi ciencies
.
The installation must conform with local codes or, in
the absence of local codes with the National Fuel Gas
Code
, ANSI Z223.1or the Natural Gas and Propane
Installation Code
CAN/CGA-B149. Only qualifi ed
licensed or trained personnel should install the
appliance.
The appliance, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical
Code
, ANSI/NFPA 70 or the Canadian Electrical Code,
CSA C22.1.
Ratings
*Tested to CGA - 2.17-91 Gas fi red appliances for use
at high altitudes
. In USA, installations may require
deration over 2000’ —Check local codes.
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas utility
to confi rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Supply Gas
Heater engine 530INI is used for natural gas insert
installations.
Heater engine 530IPI is used for propane gas insert
installations.
The supply pressure must be between the limits shown
in the Ratings table on the previous page.
The supply connection is 3/8 inch NPT female located
at the left side of the control valve.
The opening for the gas supply line is at the rear left
corner of the appliance.
Fuel Beds
The 530 engine is available in either natural gas or
propane gas can use a simulated logs, coals, or rocks
fuel bed in either fuel.
Electrical
The unit does not require an electrical power source
unless fi tted with an optional circulating fan.
Floor/Hearth
This appliance is approved for installation into existing
solid-fuel burning fi replaces only. Combustible material
such as plywood and so on may be used for leveling
and shiming beneath the unit. This appliance does not
require a hearth other than to support the weight of
certain fronts.
Front Trims
Various fronts are available for the 530 insert engine.
This engine must be installed as an insert application.
The front trim style affects the depth of insert
cavity and position of the engine. A front trim kit
is required for all applications and should be on
site when the engine is installed. 536/541/563 fronts
require a closure plate (582/583CPB) to ensure proper
positioning of the casting.
Gas supply connection
3/8” NPT female at valve
Gas line
access at
rear left
corner
Model NG
LPG
Gas
natural
propane
Altitude (ft)*
0-4 500 pieds*
Input max. (Btu/h)
20,500
19,000
Input min. (Btu/h)
6,500
12,500
Manifold pressure (in w.c.)
3.5–3.9
10.3–10.7
Min. supply pressure (in w.c.)
5
11
Max. supply pressure (in w.c.)
10.5
14
Main burner injector (no.)
580
200
Pilot injector (no)
35
27
Min. by-pass screw
125
125
QUALIFIED
INSTALLER