Section 6: Installing the Inverter and Charger Remote Status Display
Panels
There are two remotes available for the 20-1050CUL-DC, One for Inverter Status (Part Number
– LSIR)
and the other is for Charger Status (Part Number
– LSCR). Both the Inverter and Charger Remote Status
Display Panels contain a red and green LED indicator, On the charger status panel, a SOLID green light
indicates the presence of shore power or that the battery is being maintained at its current level. A
FLASHING green light indicates the presence of shore power and the charger is in high charge mode. On
the inverter status panel, the SOLID green indicator light signifies the unit is ON, a FLASHING light
indicates the unit is in the Standby mode. For both the remotes the red Fault LED indicator shows
problems such as over temperature, output overload, or low battery.
The panels have a gasket seal which will keep the electronics safe from weather and water spray. Each
panel is equipped with a RJ45 connector for easy installation and replacement. The following installation
procedure applies to both the inverter and charger panels:
Step 1: Select a location for the panel.
Identify the desired location for the inverter and/or charger panels.
Step 2: Route cable.
Carefully route the modular cable from the front of the LifeStar to the remote location. This cable does not
need to be shielded but it should be routed away from the AC cables.
Step 3: Secure panel to surface.
Remove the protective liner from the gasket and mount the panel using the provided #8 screws through
the two holes in the panel.
POWER INVERTER
Fault
Standby
ON
Fault
AC ON/
High Charge
AC ON/
Maint. Charge
CHARGE INDICATOR
2.22
1.11
Remote Mounting
Pattern
Fault
Ø 0.110 (#35 Drill Bit) Hole (2 PLCS)
Ø 1.875 (1 7/8) Hole
2.360
3.015