Vanner LIFESTAR 20-1000TUL-DC Owner's Manual - Vanner
VANNER
Incorporated
Owner’s Manual
LifeStar Owner’s Manual - 6 -
Section 4: Specifications
Inverter
20-1050CUL-DC
20-1000TUL-DC
Output at 120 VAC RMS (Continuous Power Rating)
1050 Watts
Surge Capacity at 120 VAC (3 sec)
2100 Watts
Input Voltage, VDC
(Deep Cycle Battery Recommended)
12 VDC, Nominal
10.5 VDC min, 16.0 VDC max.
AC Output Voltage
120 VAC
5%
DC Current Draw (Battery)
OFF
0.017 Amps Typical
In Load Demand
0.09 Amps Typical
Full ON at No AC Load
0.7 Amps Typical
Full On with Load
Approx. AC Load Watts
10
Frequency
60 Hz
0.2%
Output Wave Form
Modified Sine Wave
Battery Charger
Charging Capacity (note “DC Source” section below)
55 Amps (High)
15 Amps (Low)
N/A
Input Voltage
120 VAC
10%
N/A
Input Current
12.0 Amps
N/A
Bulk Voltage
14.2 VDC (flooded), 14.1 VDC
(gel)
N/A
Float Voltage
13.2 VDC (flooded), 13.6 VDC
(gel)
N/A
Bypass Transfer
Output Current, GFCI Outlet *
12 Amps
DC Source
Output Voltage
Battery Voltage
Output Current
20.0 Amps Max. (Current must be subtracted from
“Charging Capacity” above)
Other Specifications
AC Input Termination**
3ft. Line Cord
AC Output Termination
Duplex GFCI Receptacle
Ambient Temperature
-20
to +110
F, -29
to +43.4
C
Cooling Air
Fan Cooled
Chassis
Aluminum
Dimensions
11.57”W x 5.94”H x 11.04”D
Weight
22 BS
* Note: If GFCI trips and the inverter is in Load Demand mode the GFCI may not reset until you toggle inverter off and back
on then you will have 5 seconds to reset GFCI before unit goes back into Load Demand mode again or you can disable Load
Demand mode via dipswitch, if available.
** AC input branch rated overcurrent protection is to be provided by others to comply with the National Electric Code,
NFPA 70.