Vanner VLT12-1000 Owner's Manual - page 11
VANNER
Incorporated
VLT Series True Sine Wave Inverter - Owner’s Manual
11
(9) Under Voltage Indicator
Indicates that the inverter has shut itself OFF due to input voltage under 10.0 volts (20.0 volts for 24 volt
models).
(10) Over Temperature Indicator
Indicates that the inverter has shut itself OFF due to overheating. The inverter may overheat if operated
at power levels above its rating, or if installed in a location that does not allow for proper ventilation. The
inverter will restart automatically after a cooling period.
(11) Overload Indicator
The inverter has shut OFF because its output has been short circuited or drastically overloaded. Turn
the ON/OFF switch to the OFF position, correct the fault condition, and turn the inverter back ON.
(12) ON/OFF Switch (and RESET Switch)
The ON/OFF Switch is a two-position rocker switch used to turn the inverter ON/OFF and is used as a
RESET Switch. When the inverter has automatically shut itself OFF due to a fault, the inverter must be
RESET by turning the ON/OFF Switch OFF or by turning a remote switch OFF. (If an automatic shut-
down has occurred due to a fault, one of the fault indicator lights will be displayed until the inverter is
RESET.
(13) Inverter Indicator Light
Light Display
Description
Green Light is OFF
Inverter is OFF
Solid Green
Inverter is ON and is producing AC power
Blinking Green
Inverter is in Load Demand Mode
(14) Factory set-up dip switch
(Not present on 600-watt models.)
(15) Air
Intake Vents
(16) Mounting Base Rails ( 2 )
(17) GFCI Duplex Receptacle