Figure 8 - Attaching Top Surround Panel
Figure 9 - Attaching Side Panels to Top
Panel
Top Surround
Panel
Top Panel
Side
Panel
Phillips
Screws (4)
Top Edge of
Fireplace Insert
Phillips Screws
5. Place top surround panel at top of fire-
place insert. Bottom edge of panel will
slide under top edge of insert. Align top
panel screw holes with those in insert.
Install four #8 Phillips screws, do not
tighten. See Figure 8.
6. Align screw holes in side panels with
holes in top panel (see Figure 9). Insert
and tighten #8 Phillips screws.
7. Reinstall louver removed in step 4,
page 10.
8. Carefully inspect fireplace surround as-
sembly. Make sure each part fits properly.
Firmly tighten all screws installed during
assembly.
CAUTION: Do not overtight-
en. Metal can bend, warp or break
under excessive strain.
9. Install trim after final finishing and/or paint-
ing of wall.
INSTALLATION
Continued
INSTALLING HOOD
Install hood to top of firebox as shown in
Figure 10. Use 5 Phillips screws (provided)
to attach hood to fireplace insert and 2 Phil-
lips screws (provided) to attach hood and
surround sides to fireplace insert.
Figure 10 - Installing Hood to Firebox
Screws
INSTALLATION CLEARANCES
WARNING: Maintain the
minimum clearances. If you can,
provide greater clearances from
floor, ceiling and adjoining wall.
Carefully follow instructions below. This will
ensure safe installation.
Minimum Clearances For Side Combustible
Material, Side Wall and Ceiling
A. Clearances from side of fireplace cabinet to
any combustible material and wall should
follow diagram in Figure 12, page 12.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
1
/
2
" from the wall. This com-
bustible material must be 4” from side of
fireplace opening (see Figure 11).
B. Clearances from top of fireplace opening to
ceiling should not be less than 42".
Figure 11 - Minimum Clearance for
Combustible to Wall
*Minimum 16" from Side Wall
*
Example