Venmar AE60 Installation And User Manual - 5.3
24
5.3
M
ASTER
R
ESET
5.
MAINTENANCE
(CONT’D)
Use the master reset only if you perform the annual maintenance before the annual
maintenance indicator is on. By inserting a small rod (e.g.: paper clip end) during 5 seconds
and more into the control reset hole, a master reset will be done and both biannual and
annual maintenance filter are reset.
If the control is on “O
”
position, fresh air light indicator will flash for 1 second.
If the control is on Minimum or Maximum position, the unit motor and the fresh air light
indicator will turn off for
3
seconds.
If the control is on Recirculation position, the unit motor will turn off during
3
seconds.
6.
TROUBLESHOOTING
If the problem is still not solved, call your installer or the nearest approved Service Center.
You can also reach the Customer Service Department at the following telephone numbers:
Exclusively for model AE60: 1-800-6
3
7-145
3
.
Exclusively for model EA1500: 1-800-567-
3
855.
Exclusively for model HV 1.5: 1-866-7
3
7-7770.
PROBLEMS
SOLUTIONS
1. Unit does not start on Minimum
or Maximum position.
• Check breaker or fuse in main distribution panel.
• Check if there is 120V at the electrical outlet.
2. Unit does not run on Minimum,
but runs on Maximum.
• Check control wiring and control connections.
3
. Unit does not work.
• The fuse may be blown. Unplug the unit. Unscrew
the electrical enclosure. Check if the fuse is blown
on the electronic control board (the strand is
broken). If it is blown, replace the fuse with the
exact same type.
4. Unit is not operating as per
the selected mode.
• Check control wiring.
5. Control indicators do not work
properly or not at all.
• Check control wiring.
6. Air is too dry.
• Avoid operating the unit on Maximum mode.
• Use the Recirculation mode.
7. Persistant condensation.
• Turn on the central heating system.
• Store the firewood outside the house.
• Do not completely close curtains, blinds, etc.