    Sv09865 rev. 02 cic700 series intended for domestic cooking only installer: leave this manual with homeowner. Homeowner: use and care information on pages 15 to 18. Venmar ventilation inc., 550 lemire blvd., drummondville qc j2c 7w9 1-800-567-3855 register your product on line at: www.Bnv.Ca for add...

  • Page 2: Warning

    Warning to reduce the risk of fire, electric shock or injury to persons, observe the following: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning...

  • Page 3: Table of Contents

    Table of contents 1. I nstall ductwork . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 2. P repare the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 3. P repare hood . . . . . . . . . . . . . ....

  • Page 4: 1. Install Ductwork (

    Installation over a gas range: refer to gas range manufacturer’s guidelines for the recommended cfm. If two cic700 series range hoods are required, the minimum space between the hoods should not be less than 1”. Hh0154a 1" m in . - 4 - 1. Install ductwork ( cont ’ d ) 2. Prepare the installation whe...

  • Page 5: 3. Prepare Hood

    2. Disconnect power cord from electrical box and disconnect blower. - 5 - 1. Rest the range hood on a table. Use a piece of cardboard to avoid damaging the table or the hood. Remove tape on filters. Lift filters by pushing them towards the back (opposite control side) and rotate, then set filters as...

  • Page 6: 4. Measure Installation

    - 6 - 4. Measure installation determine angle brackets length needed based upon ceiling height ( b ) and desired height of hood above cooktop ( a ). The table below indicates which flue(s) to use and the number of brackets required according to height ( c ). Hh0156a c b a c eiling c ooktop b lower b...

  • Page 7

    - 7 - 5. Install mounting bracket 1. Modify ceiling stucture at hood location. Install 2" x 4" cross framing between ceiling joists using ceiling mounting bracket dimensions shown at right. The framework must be sized to support the total weight of the hood and should not be larger than 9¾" x 9¾". 1...

  • Page 8: ’

    - 8 - 5. Install mounting bracket ( cont ’ d ) 3. Position the mounting bracket in such a way that one of the sides without a “t” will be facing the front of the hood. Secure mounting bracket to the ceiling using 8 no. 10 x 1½" wood screws (2 for each corner). Make sure screws are driven into the ce...

  • Page 9: 6. Assemble Angle Brackets

    1. Assemble 4 angle brackets to the ceiling mounting bracket using at least two no.10-32 x 1/2" quadrex screws per angle bracket. Notes: 1. Do not tighten the screws yet. 2. Depending on the height needed ( c ) (previously determined in section 4), the angle brackets might not touch the ceiling as i...

  • Page 10: ’

    1. Remove electrical box cover both retaining screws. Set cover and screws aside. 2. Install wire clamp (included) on top of blower box. Attach the adapter/damper to the blower box using 4 no. 8 x 3/8" quadrex screws (included). Remove tape on damper. (angle brackets not illustrated to ease understa...

  • Page 11: 7. Connect Wiring (

    - 11 - 7. Connect wiring ( cont ’ d ) 3. Run house wiring through wire clamp and into blower box electrical box. Tighten wire clamp to secure house wiring cable to blower box. 4. Measure the required length of 8" round metal duct from the adapter/damper to the ductwork rough-in in the ceiling. Conne...

  • Page 12: 8. Install Glass Panels (

    1. Slide the upper flue up to the ceiling and secure it to the ceiling mounting bracket using 2 no. 8 x 1/2" quadrex screws. Note: ensure upper and lower flue seams are aligned . Carefully slide the lower flue over the upper flue up to the ceiling and have the second person hold it to the ceiling wh...

  • Page 13: 9. Install Hood (

    9. Install hood ( cont ’ d ) - 13 - 2. Slide hood over blower box and attach to blower box using the 4 screws previously removed from step 3.3 (some parts not illustrated to ease understanding). Note: for more convenience, a total of 16 holes (4 holes per section) are available to secure the hood, b...

  • Page 14: 10.Reinstall Baffle Filters

    To replace bulbs: 1. Gently push upward and turn counterclockwise to disengage bulb leads from their grooves. 2. Place the new bulb leads into their grooves in the socket. 3. Gently push upward and turn clockwise until secured. Note: if need be, use a rubber dishwashing glove to add grip when removi...

  • Page 15: 12. Care

    12. Care warning before servicing or cleaning the unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service pane...

  • Page 16: 13. Operation (

    13. Operation ( cont ’ d ) - 16 - hc0052 a b c d e f g a) blower delay/control lock button b) blower low speed button — linklogic ® erase link button c) blower medium-low speed button — linklogic ® master link mode button d) blower medium-high speed button — linklogic ® auto link mode button e) blow...

  • Page 17: 13. Operation (

    13. Operation ( cont ’ d ) - 17 - g. L ight b utton /b acklighting c olor (d ouble f unction b utton ): i. This button allows four different lighting levels according to your needs. Press once for full intensity, twice for intensity level 3 , three times for intensity level 2 and once more for night...

  • Page 18: 13. Operation (

    13. Operation ( cont ’ d ) - 18 - e rase l ink p rocess 1.A ctivate the l ink mode of the range hood push and hold button e for 3 seconds. After the 3-second hold, button e backlight blinks 3 times quickly (low to high intensity) and then all 4 speed levels backlights start to oscillate between mid ...

  • Page 19: 15.Wiring Diagram

    U ser i nterfac e l ow m ed l ow m ed h igh h igh c ontr o l bo ard l amp l ine l ine n eutral j4 j6 j5 j8 blu wht org blk yel blk wht wht he0 12 7a 120 vac l ine n eutral g r ound f an mo to r blu wht org blk gr y brn wht 25 µf 4 3 2 1 3 2 1 3 2 1 col or code blk blu brn gr y org bla ck blue br o w...

  • Page 20: 16.Service Parts

    Hl0158 4 5 12 7 6 1 2 14 1 3 15 3 8 9 10 11 16.Service parts r eplacement p arts and r epairs in order to ensure your unit remains in good working condition, you must use venmar ventilation inc. Genuine replacement parts only. Venmar ventilation inc. Genuine replacement parts are specially designed ...